• 제목/요약/키워드: Main Power Transformer

검색결과 192건 처리시간 0.025초

한국형 고속전철 추진성능 검증을 위한 추진시스템 통합시험 (Traction System Combined Test of KHST for Propulsion System Performance Verification)

  • 류홍제;김종수;김용주;노애숙;정은성;최종묵
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.886-890
    • /
    • 2003
  • This paper introduces the combined test results of the traction system for KHST(Korean High Speed Train: hereafter refer to KHST). The main purpose of this combined test is to verify the performance of the traction system that is designed to operate up to maximum 350km/h speed. Combined test system consists of a traction transformer, two AC-DC PWM converters, a PWM Inverter, two traction motors and flywheel system. Flywheel system represents equivalent model of the train inertia. Also traction control system and MASCON Interfaces are included. Various kinds of experiments are performed to prove total traction system performance and detail waveforms are described

  • PDF

765 KV 변전설비 예방진단 전문가 시스템 기본설계 (Basic design of the preventive diagnostic expert system for 765kV substation equipments)

  • 최인혁;권동진;정길조;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2133-2135
    • /
    • 1999
  • In this paper, we describe the basic design of the preventive diagnostic expert system for 765kV substation equipments. This expert system is developed to use expert system development tool and the main subjects considered are 765kV class power transformer and GIS. We basically designed the total structure of expert system and considered database interface methods, inference engine and control, triggering system which compose expert system.

  • PDF

고효율을 갖는 단일 전력변환 직렬 공진형 AC-DC 컨버터 (Single-Power-Conversion Series-Resonant AC-DC Converter with High Efficiency)

  • 정서광;차우준;이성호;권봉환
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.224-230
    • /
    • 2016
  • In this study, a single-power-conversion series-resonant ac-dc converter with high efficiency and high power factor is proposed. The proposed ac-dc converter consists of single-ended primary-inductor converter with an active-clamp circuit and a voltage doubler with series-resonant circuit. The active-clamp circuit clamps the surge voltage and provides zero-voltage switching of the main switch. The series-resonant circuit consists of leakage inductance $L_{lk}$ of the transformer and resonant capacitors $ C_{r1}$ and $ C_{r2}$. This circuit also provides zero-current switching of output diodes $D_1$ and $D_2$. Thus, the switching loss of switches and reverse-recovery loss of output diodes are considerably reduced. The proposed ac-dc converter also achieves high power factor using the proposed control algorithm without the addition of a power factor correction circuit and a dc-link electrolytic capacitor. A detailed theoretical analysis and the experimental results for a 1kW prototype are discussed.

화력 발전소의 터빈 발전기 부하단에 설치된 XLPE 케이블의 부하전류 측정 (Measurements of Load Current of XLPE Cables Installed at the Load Terminal of Turbine Generator in Operation at Thermoelectric Power Station)

  • 엄기홍;김보경
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.207-212
    • /
    • 2017
  • 화력 발전소의 터빈 발전기에서 생산된 전기를 운반하기 위하여 부하 측에 설치된 케이블은 XLPE 케이블(또는 CV케이블)이다. 사고 발생시 저압 시스템을 포함하는 대부분의 설비들에 정전사고가 발생하여 막대한 경제적 손실을 초래한다. 설계부터 시공 및 관리를 더욱 철저히 해야 한다. 설치환경 및 사용 조건 부하량 등에 따라 차이가 있겠지만, 증설과정, 부적절한 설계 등으로 인하여 케이블의 단면적이 부족할 경우가 발생하며, 운전 전류에 의하여 초과된 허용온도는 케이블의 열화 상태를 초래한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korean Western Power Co. Ltd.)에 설치하여 활선상태에서 케이블에 흐르는 부하전류를 측정하였다. 이 논문에서 우리는 케이블에 흐르는 부하전류를 측정하고, 측정된 부하전류에 의한 부하특성의 파악 및 IEC규정에 의한 허용전류와 비교하여 케이블의 도체온도를 파악하기 위한 기초자료를 제시한다.

새로운 방식의 PFC Single Stage Full Bridge AC/DC Converter (New Single Stage PFC Full Bridge AC/DC Converter)

  • 임창섭;권순걸
    • 융합신호처리학회논문지
    • /
    • 제3권3호
    • /
    • pp.70-75
    • /
    • 2002
  • 본 논문은 새로운 단일 전력단 역률보상 풀 브리지 컨버터를 제안하였다. 제안된 컨버터는 역률보상을 위하여 앞단에 2개의 인덕터, 2개의 다이오드, 2개의 자성결합 변압기를 가진 2VS 풀브리지 DC/DC 컨버터로 구성되어 있다. 이러한 구성방법에 의해 전력은 전원에서 분리되고, 안정된 직류출력전압을 얻을 수 있다. 이 토폴로지에서 주소자의 전압스트레스는 영전압스위칭에 의해서 감소되며, 또한 제안된 컨버터는 능동 역률보정 스위치와 제어 및 게이팅 보드와 같은 보조회로가 필요치 않게되어 규격과 단가를 낮출 수 있을 뿐 아니라 효율을 증가시킬 수 있다.

  • PDF

상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • 제24권1호
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

휴대형 고전압 발생기에 대한 전자기기의 내성 (Immunity of Electronic Equipments Against Potable High Voltage Generator)

  • 이종익;여준호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.61-62
    • /
    • 2017
  • 본 연구에서는 최근 상용화된 휴대 가능한 소형 고전압 발생기의 주요 기능과 제원에 대해 소개한다. USB 킬러는 USB 포트를 사용하는 전자기기의 과전압 입력에 대한 보호회로를 시험하기 위한 용도로 개발되었다. USB 포트에서 공급되는 5 V 직류 전압을 발진기, 변압기, 배전압 정류회로를 통해 200 V이상의 충분히 높은 직류 전압으로 변환시킨다. 고용량 커패시터에 충전된 전압을 USB 포트를 통해 역방향으로 전자기기에 충격을 가하여 전자기기를 파괴하거나 보호회로를 시험 할 수 있다. USB 킬러는 개인이 쉽게 구입하여 전자기기를 시험해 볼 수 있다. 인터넷을 통해 공개된 시험 결과들과 실제 시험을 통해 확인된 결과들을 소개한다.

  • PDF

저압 배전망 감시기능을 포함하는 개선된 배전자동화시스템 개발 (The Development of An Improved Distribution Automation System Including Low Voltage Monitoring Function)

  • 신창훈
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.1034-1041
    • /
    • 2007
  • 본 논문은 저압 감시 기능을 포함하는 개선된 배전자동화시스템 개발에 관한 연구 결과를 소개한 것으로서 연구배경, 시스템 구성, 설계, 시제품 제작, 시험 및 실계통 시범운영 등 전반적인 사항을 설명한다. 개발 시스템은 배전현장에서 별도로 수행 중인 변압기 부하감시, 전압감시 및 정전감시 및 품질감시 업무를 배전자동화시스템에 통합하여 운영함으로써 보다 경제적이고 효율적인 배전망의 운영을 위하여 개발되었다. 시스템 통합을 위한 통신망은 간선망과 지선망을 갖도록 계층적으로 구성하고, 변압기 부하 측의 저압 감시를 위한 단말장치를 새로 개발하였다. 또한, 기존 배전자동화시스템에 저압 감시 기능을 추가하기 위하여 주장치 소프트웨어를 개선하였다. 개발 시스템은 실계통 시범운영을 통하여 설계 및 성능이 검증되었다.

  • PDF

Pulse-width Adjustment Strategy for Improving the Dynamic Inductor Current Response Performance of a Novel Bidirectional DC-DC Boost Converter

  • Li, Mingyue;Yan, Peimin
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.34-44
    • /
    • 2018
  • This paper presents a pulse-width adjustment (PWA) strategy for a novel bidirectional DC-DC boost converter to improve the performance of the dynamic inductor current response. This novel converter consists of three main components: a full-bridge converter (FBC), a high-frequency isolated transformer with large leakage inductance, and a three-level voltage-doubler rectifier (VDR). A number of scholars have analyzed the principles, such as the soft-switching performance and high-efficiency characteristic, of this converter based on pulse-width modulation plus phase-shift (PPS) control. It turns out that this converter is suitable for energy storage applications and exhibits good performance. However, the dynamic inductor current response processes of control variable adjustment is not analyzed in this converter. In fact, dc component may occur in the inductor current during its dynamic response process, which can influence the stability and reliability of the converter system. The dynamic responses under different operating modes of a conventional feedforward control are discussed in this paper. And a PWA strategy is proposed to enhance the dynamic inductor current response performance of the converter. This paper gives a detailed design and implementation of the PWA strategy. The proposed strategy is verified through a series of simulation and experimental results.

Half-Bridge 직렬 공진컨버터 적용 비접촉 충전시스템 (A Contactless Power Charging System using Half-Bridge Series Resonant Converter)

  • 김주훈;송환국;김은수;박성호;김윤호
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.251-259
    • /
    • 2009
  • 본 논문에서는 비접촉 시스템에 있어서 스위칭 소자의 영 전압 스위칭(ZVS)뿐만 아니라 2차측 정류 다이오드 역시 영 전류 스위칭(ZCS)을 이룰 수 있는 비접촉 변압기를 이용한 Half-Bridge 직렬 공진 컨버터 적용 비접촉 충전 시스템을 제안 적용하였다. 본 논문에서 제안한 비접촉 변압기 적용 Half-Bridge 직렬 공진컨버터는 공진 주파수보다 낮은 영역에서 스위칭 동작이 가능하기 때문에 불연속 공진전류에 의한 2차측 정류 다이오드의 영 전류 스위칭(ZCS)이 가능하다. 또한 좁은 주파수 영역에서 제어가 가능하며 높은 전압 이득특성에 따라 적은 턴-수비의 변압기를 사용할 수 있으므로 기존의 비접촉 시스템과 비교해 보았을 때 효율특성을 개선시킬 수 있다. 시뮬레이션과 이론적인 분석을 토대로 3.15W 시제품을 제작하고 실험내용을 서술했다.