• Title/Summary/Keyword: Main Power Transformer

Search Result 192, Processing Time 0.023 seconds

Numerical Analysis on the Electromagnetic Phenomena in High Power Isolated Phase (대전력용 상분리 모선의 전자계 현상 수치해석)

  • Kim, Jin-Soo;Ha, Duk-Yong;Choi, Seung-Kil;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1990-1992
    • /
    • 2000
  • Isolated phase bus is, as a special bus which allows large current from a generator to main transformer, composed of main conductor, enclosure and auxiliary equipments such as insulating bellows, bus elbows, support insulator, etc. To develop this kind of high power devices, it is required to secure the technique of selection of conducting and insulating materials, basic arrangement skills, and analysis on eddy current which causes temperature increase in enclosures. By the way, these techniques are based on the analysis of electromagnetic phenomena for high voltage and large current. In this study, an electromagnetic field analysis program is developed and applied to the isolated phase bus. which could be the basic numerical method for the analysis design and modifying isolated phase bus.

  • PDF

Design and Implementation of a Trigger Circuit for Xenon Flash Lamp Driver (제논 플래시 램프 구동장치를 위한 트리거 회로 설계 및 구현)

  • Song, Seung-Ho;Cho, Chan-Gi;Park, Su-Mi;Park, Hyun-Il;Bae, Jung-Su;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.138-139
    • /
    • 2017
  • This paper describes the design and implementation of a trigger circuit which can be series connected with main pulse circuit for a xenon flash lamp driver. For generating high voltage, the trigger circuit is designed as an inductive energy storage pulsed power modulator with 2 state step-up circuit consisting of a boost converter and a flyback circuit. In order to guarantee pulse width, a resonant capacitor on the output side of the flyback circuit is designed. This capacitor limits the output voltage to protect the flyback switch. In addition, to protect another power supply of xenon flash lamp driver from trigger pulse, the high voltage transformer which can carry the full current of main pulse is designed. To verify the proposed design, the trigger circuit is developed with the specification of maximum 23 kV, 0.6 J/pulse output and tested with a xenon flash lamp driver consisting of a main pulse circuit and a simmer circuit.

  • PDF

Development of Equipment Measuring Insulation Resistance of High-Power Cables in Operation at Power Station (발전소에서 운전 중인 고전력 케이블의 절연저항의 변화를 감시하는 장치의 개발)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.159-164
    • /
    • 2016
  • In or to generate high electric power in increasing demand, power station should operate facilities to meet requirement. The scale of electric power equipment is increasing in both size and complexity. With unexpected accidents at power facilities or power stations happening, substantial socioeconomic losses in an industrial society is caused. A major cause of unexpected accidents is deterioration of dielectrics, isolating two conductors electrically. In order to detect the deterioration processes of power cables, the operation status of power cables should be monitored on a regular basis. We have invented and installed equipment at Korea Western Power Co., Ltd., located in Taean, in order to predict and prevent the deterioration status of dielectrics destruction of power cables. The main line in Y-connection to the secondary coils of transformer delivers electric power to the external devices. The equipment we developed is the one measuring insulation resistance of cables operation in on/off status with respect to the main line. We present the equipment in terms of operation and configuration of hardware side.

Suppression Control Method of Torque Ripple for IPMSM Utilizing Repetitive Control and Fourier Transformer

  • Hattori Satomi;Ishida Muneaki;Hori Takamasa
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.341-345
    • /
    • 2001
  • Recently, many examples of practical applications of the motors with reluctance torque, such as IPMSM, RM, etc. are reported. However, the problems of the torque ripple produced by the IPMSM, are also presented. The main reasons of the torque ripple generation are the structural imperfectness of the IPMSM and its control system, such as the cogging torque of the motor, the dead time of inverter, sensors offset, imbalance and non-linearity, and so on. In this paper, authors propose a suppression control method of the torque ripple for IPMSM utilizing the repetitive control with the Fourier transformer and a vibration signal detected by an acceleration sensor attached to the motor frame, considering periodicity of the motor torque ripple. An experimental system to simulate the compliant mechanical frame is constructed, and the effectiveness of the proposed method is confirmed by experimental results.

  • PDF

Series Compensated AC Voltage Regulator using AC chopper with Auxiliary Transformer (교류쵸퍼와 보조변압기를 사용한 직렬보상형 교류전압제어장치)

  • Ryoo H.J.;Kim J.S;Rim G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.106-109
    • /
    • 2003
  • This paper describes an AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. A detail study of step down AC voltage regulator is described and two kinds of novel step-up/down voltage regulator for AVR are proposed. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as AC voltage regulator for special purpose very efficiently.

  • PDF

Operating characteristic of surge counter (Surge arrester용 surge counter의 동작 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Byeon, Jin-Ho;Lee, Kang-Sup;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1134-1137
    • /
    • 2004
  • The main function of surge counter is knowing the times of surge flowed in, which is installed under surge arrester. Two methods are presented in this paper to get the electric power for mechanical movement and detect the surge with surge counter. One is using ZnO varistor resister and the other is using the current transformer.

  • PDF

The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

A New DC-DC Full-Bridge Converter with Using Regenerative Transformer (회생변압기를 이용한 새로운 전력회수형 풀브리지 컨버터)

  • Kim, J.H.;Hyun, B.C.;Lee, J.M.;Cho, B.H.;Lee, D.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.395-398
    • /
    • 2005
  • A novel full-bridge converter with a new energy-recovery driver implemented a regenerative transformer is proposed to improve the efficiency for wide input voltage range and load variation. The main switches achieve ZVS independent of the load current condition. During the free wheeling period, conduction loss is minimized by recovering the circulating energy to the source. The principle of operation, design consideration and experimental result, including efficiency, are presented in the case of large variation of the input voltage or load. A proposed 1kW converter prototype is compared with a PS-FB converter.

  • PDF

Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis (회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가)

  • 오광해;차준민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

New Single Stage Power Factor Correction AC/DC Converter based on Zero Voltage Switching Full Bridge Topology (영전압 스위칭 풀 브릿지 토폴로지를 기반으로 한 새로운 단일 전력 단 역률개선 AC/DC 컨버터)

  • Kim T.S;Koo G.B;Moon G.W.;Youn M.J
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.352-357
    • /
    • 2003
  • A new single stage power factor correction(PFC) AC/DC converter based on zero voltage switching(ZVS) full bridge topology is proposed. Since the series-connected two transformers act as both output inductor and main transformer by turns, the proposed converter has a wide ZVS range without additional devices for ZVS. Furthermore, since there is no need to use an output inductor, the proposed converter features high power density. The proposed converter gives the good power factor correction and low line current harmonics distortion. A mode analysis and experiment results are presented to verify the validity of the proposed converter.

  • PDF