• Title/Summary/Keyword: Main Link

Search Result 485, Processing Time 0.02 seconds

Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation (분산모듈형 태양광 전력조절기의 독립운전 제어)

  • Seo, Jung-Won;Park, Joung-Hu;Kim, Hye-Rim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

Hybrid simulation tests of high-strength steel composite K-eccentrically braced frames with spatial substructure

  • Li, Tengfei;Su, Mingzhou;Guo, Jiangran
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.381-397
    • /
    • 2021
  • Based on the spatial substructure hybrid simulation test (SHST) method, the seismic performance of a high-strength steel composite K-eccentrically braced frame (K-HSS-EBF) structure system is studied. First, on the basis of the existing pseudostatic experiments, a numerical model corresponding to the experimental model was established using OpenSees, which mainly simulated the shear effect of the shear links. A three-story and five-span spatial K-HSS-EBF was taken as the prototype, and SHST was performed with a half-scale SHST model. According to the test results, the validity of the SHST model was verified, and the main seismic performance indexes of the experimental substructure under different seismic waves were studied. The results show that the hybrid simulation results are basically consistent with the numerical simulation results of the global structure. The deformation of each story is mainly concentrated in the web of the shear link owing to shear deformation. The maximum interstory drifts of the model structure during Strength Level Earthquake (SLE) and Maximum Considered Earthquake (MCE) meet the demands of interstory limitations in the Chinese seismic design code of buildings. In conclusion, the seismic response characteristics of the K-HSS-EBFs are successfully simulated using the spatial SHST, which shows that the K-HSS-EBFs have good seismic performance.

Design of Heavy Weight Door Hinge for Built-in Appliances (빌트인 가전기기용 고 중량 도어힌지의 설계에 관한 연구)

  • Choi, Seong-Dae;Byn, Yong-Kun;Kim, Gi-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.41-47
    • /
    • 2021
  • In this study, the hinges of heavy weight doors were designed and analyzed in line with the trend that built-in appliances are becoming larger and the weight of doors is also increasing. The main specification of the heavy weight door hinge is to allow the deflection at the end of the door to be less than 2 mm when opening and closing, including the automatic closing, slow closing, and closing force control functions. The structural analysis of the design mechanism, component design, and methods for improving the deflection are as follows: 1) Mechanism of the automatic closing function should sense automatically using the spring compression force at a specific angle by the contact between the cam and the cam module roller. 2) Through structural analysis, the maximum stress of the door was found in the link pin hole connected to the pin at each link. 3) Consequently, the pin holder was designed and applied, with little variance, but up to 93% of the specification limit.

"Leisure Life Satisfaction:" Will It Have a Beneficial Impact on Depression Among Older Adults in Community Care Settings in Korea?

  • Kim, Il-Ho;Kim, Cheong-Seok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.4
    • /
    • pp.398-406
    • /
    • 2022
  • Objectives: While the risk of depression is expected to substantially increase among older adults receiving community care, leisure life satisfaction can be regarded as a key component in enhancing the mental health of those receiving community care. However, it is not yet known whether community care utilization increases the risk of depression, or what role is played by leisure life satisfaction in these settings. This study investigated the relationship between community care utilization and depression, as well as the main effect and the moderating role of leisure life satisfaction on the link between community care utilization and depression among older adults. Methods: This study, using the 2019 Korean Welfare Panel Survey, conducted multiple regression analysis on data from 4494 elderly people aged 65 years or older. Results: After controlling for potential covariates, older community care recipients were more likely to report symptoms of depression than those who did not receive community care. Meanwhile, leisure life satisfaction was negatively associated with depression in older adults. The test for interaction between community care utilization and leisure life satisfaction revealed that leisure life satisfaction significantly attenuated the link between depression and community care utilization. Conclusions: The findings of this study imply that leisure life satisfaction could play a meaningful role in improving the mental health of older adults receiving community care. Welfare policies affecting older adults should consider leisure life satisfaction as an important resource for reducing depression in community care settings.

A Study for Optimized Detecter Location Considering the Traffic Characteristics in National Highway (일반국도 통행특성을 고려한 지점검지기의 적정설치지점 선정에 관한 연구)

  • Byeon, Sang-Cheol;Lee, Seung-Jae
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.2 s.88
    • /
    • pp.19-30
    • /
    • 2006
  • This study deals with the optimized detector location considering the traffic characteristics in National Highway. Although there ave many construction works for ITS in National Highway, there is not specific criteria for detector location which can effect the accuracy of traffic information. This study. therefore. aims to Provide the optimized detector location criteria which can represent the traffic characteristics of National Highway. It collects traffic factors of study area by GPS Probe-car and defector, and Presents the optimized detector location by the correlation analysis between spot-speed and link-travel-time. The main results of this study are as followings ; First, the correlation between the spot-speed and link-travel-time Presents the opposite bell shape of the graph (U-type owe) which is increased it?on the upstream then, declined through some unspecified Point of the link. Second, the optimized detector location usually distributes around midstream of link, even though it does not have a consistency. Third, therefore, the optimized detector location generally should be located between $55{\sim}60%$ of total link length. Forth. high level of vertical slope is one of the most important factors of detector location, so it should be excluded for determination of optimized detector location. Finally, expecting that the results of this study would improve the accuracy of travel time estimation and forecasting.

Design of the bicycle road networks concerning the bicycle users' purposes (자전거 이용자의 이용목적에 부합하는 자전거 전용도로 설계에 관한 연구)

  • Lee, Jeabin;Huh, Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.5
    • /
    • pp.385-391
    • /
    • 2013
  • As a solution for environmental problems caused by increasing number of vehicles, it is encouraged to use a bicycle as an environment-friendly transportation method. To vitalize the bicycle usage, it is a necessary to construct bicycle roads that are safe and suitable for users. Based on the previous research results, we assume the main purposes of bicycle usages are mainly local leisure activity and school commuting. Thus, the proposed method finds the shortest link between the existing bicycle road network and bicycle usage facilities such as leisure activity places or schools over public road network. Then, we carry out the RTK DGPS survey for the candidate links, and analyze the slopes of them. When the slope of a found link is larger than a threshold, an alternative link is re-found for the safety and convenience of a bicycle user. The proposed method is applied to the real bicycle road network in Mokpo, Chunnam and the results are discussed.

Type-2 Fuzzy Logic Predictive Control of a Grid Connected Wind Power Systems with Integrated Active Power Filter Capabilities

  • Hamouda, Noureddine;Benalla, Hocine;Hemsas, Kameleddine;Babes, Badreddine;Petzoldt, Jurgen;Ellinger, Thomas;Hamouda, Cherif
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1587-1599
    • /
    • 2017
  • This paper proposes a real-time implementation of an optimal operation of a double stage grid connected wind power system incorporating an active power filter (APF). The system is used to supply the nonlinear loads with harmonics and reactive power compensation. On the generator side, a new adaptive neuro fuzzy inference system (ANFIS) based maximum power point tracking (MPPT) control is proposed to track the maximum wind power point regardless of wind speed fluctuations. Whereas on the grid side, a modified predictive current control (PCC) algorithm is used to control the APF, and allow to ensure both compensating harmonic currents and injecting the generated power into the grid. Also a type 2 fuzzy logic controller is used to control the DC-link capacitor in order to improve the dynamic response of the APF, and to ensure a well-smoothed DC-Link capacitor voltage. The gained benefits from these proposed control algorithms are the main contribution in this work. The proposed control scheme is implemented on a small-scale wind energy conversion system (WECS) controlled by a dSPACE 1104 card. Experimental results show that the proposed T2FLC maintains the DC-Link capacitor voltage within the limit for injecting the power into the grid. In addition, the PCC of the APF guarantees a flexible settlement of real power exchanges from the WECS to the grid with a high power factor operation.

Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Assessment of Livestock Infectious Diseases Exposure by Analyzing the Livestock Transport Vehicle's Trajectory Using Big Data (빅데이터 기반 가축관련 운송차량 이동경로 분석을 통한 가축전염병 노출수준 평가)

  • Jeong, Heehyeon;Hong, Jungyeol;Park, Dongjoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.134-143
    • /
    • 2020
  • With the worldwide spread of African swine fever, interest in livestock epidemics is growing. Livestock transport vehicles are the main cause of the spread of livestock epidemics, but no empirical quarantine procedures and standards related to the mobility of livestock transport vehicles in South Korea. This study extracted livestock-related vehicles' trajectory by utilizing the facility visit history data from the Korea Animal Health Integrated System and the DTG (Digital Tachograph) data from the Korea Transportation Safety Authority and presented them as exposure indexes aggregating the link-time occupancy of each vehicle. As a result, a total of 274,519 livestock-related vehicle trajectories were extracted, and exposure values by link and zone were quantitatively derived. Through this study, it is expected that prior monitoring of livestock transport vehicles and the establishment of post-disaster prevention policies would be provided.