• Title/Summary/Keyword: Main Degradation Cause

Search Result 103, Processing Time 0.025 seconds

Analysis of faust cause & insulation degradation on the electrical equipments for railway (철도용 전기기기의 고장요인 및 절연열화 분석)

  • 왕종배;전한준;박옥정;온정근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

A Study on the Environmental Degradation Factors and the Required Performance of the Waterproofing Materials Applied to Underground Structures in Residential Apartment Buildings- Survey Centered- (공동주택 지하구조물에 적용되는 방수재의 환경적 열화요인과 부위별 필요성능에 관한 연구-설문조사를 중심으로-)

  • An, Ki-Won;Kang, Hyo-Jin;Oh, Kyu Hwan;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.213-214
    • /
    • 2017
  • In this study, a survey was conducted to investigate the environmental degradation factors of specific areas in residential apartment underground structures an'd the required performance attributes for waterproofing material. Based on the survey, it was concluded that joint displacement of concrete is the highest cause for problems, and the required performance was determined to high wet surface adhesion performance for waterproofing materials.

  • PDF

The performance analysis of photovoltaic module accounting for solar cell degradation and series resistance (태양전지 셀의 열화와 직렬저항의 변화에 따른 태양전지 모듈의 특성 해석)

  • Park, Chi-Hong;Kang, Gi-Hwan;Waithiru, L.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.28-29
    • /
    • 2006
  • When photovoltaic module is used for a long time, its performance decreases due to several reasons. In this paper, we focus on the possibilities mainly contributing to the degraded efficiency of the polycrystalline silicon photovoltaic modules. The analysis is based on the modules that have been used for 15 years. These are two main reasons that cause the efficiency degradation, the corrosion and thermal decomposition. The former phenomenon of electrode is mainly due to the moisture from damaged back sheet in some module. However the other reason of the degraded efficiency comes from the thermal decomposition, which can not be observed from the outside but only by experiment. In this study, the comparison between the efficiency of normal modules and degradation modules is presented. Module having degraded cell was seen to cause increase of series resistance by about 80%, in comparison to normal samples efficiency which reduce by about 20%. This study shows that the effects of series resistances on module performance are critical. These effects must be understood and taken into consideration when analyzing performance degradation.

  • PDF

An Analysis of Streambed Changes Downstream of Daecheong Dam

  • Seo, Hyeong-Deok;Jeong, Sang-Man;Kim, Lee-Hyung;Choi, Kyu-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.103-108
    • /
    • 2008
  • Riverbed change is greatly influenced by artificial factors such as dam construction, gravel collection, and river improvement. This study simulated a long-term bed change based on the GSTARS3 model using actual data from the area downstream of the Geum River Daecheong Dam and compared the estimation with a section of the actual measurement. As a result, it was found that the section of the actual measurement was far lower than the result of the simulation in terms of long-term bed change. While the area downstream of Daecheong Dam displayed approximately an average of 2.29 m of streambed degradation on average while the upper stream area showed approximately 0.63 m of bed degradation over 24 years. In the simulation of the area downstream of Daecheong Dam based on the GSTARS3 model, similar bed degradation was observed. However, a great difference was detected between the result and the actual measurement. According to the cause analysis, the riverbed in the area downstream of Daecheong Dam has continuously degraded due to the dam construction and mass collection of gravel. The mass collection of gravel was the main cause of riverbed change. It was found that about 76% of all riverbed degradation was caused by the mass collection of gravel.

Degradation characteristics of ITO thin film deposited by RF magnetron sputter (RF 마그네트론 스퍼터로 증착시킨 ITO 박막의 열화 특성에 관한 연구)

  • 김용남;박정현;신현규;송준광;이희수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.234-234
    • /
    • 2003
  • Indium tin oxide(ITO) is an advanced ceramic material with many electronic and optical applications due to its high electrical conductivity and transparency to light ITO thin films are used in transparent electrodes for display devices, transparent coatings for solar energy heat mirrors and windows films in n-p heterojunction solar cells, etc. Almost all display devices were fabricated on transparent ITO electrode substrates. There are several factors that cause decay in the efficiency and the failure of display devices. The degradation or damage of ITO is one of the main factors. Under normal operating conditions, the electric fold required for the operation of display devices is very high As a high electric field induces the joule heat, the degradation of the ITO thin film may be expected. Therefore, it is worthy to investigate the thermal and electrical effect on ITO thin films.

  • PDF

A Mask-based Gaussian Noise Removal Algorithm in Spatial Space

  • Seo, Hyun-Soo;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.3
    • /
    • pp.259-264
    • /
    • 2007
  • According to the development and wide use of broad band internet etc., diverse application technologies using large capacity data such as images have been progressed and in these systems, for accurate acquisition and precise applications of an original signal, the degradation phenomenon generated in the transmission process etc. should be removed. Noises have become known as the main cause of the degradation phenomenon and especially Gaussian noise represents characteristics occurring dependently in image signals and degrades detail information such as edge. In this paper, we removed Gaussian noise using a subdivided nonlinear function according to a threshold value and analyzed the histogram acquired from an edge image to establish a threshold value adaptively, and strengthened detail information of image by using the postprocessing. In simulation results, the proposed method represented excellent performance from comparison of MSE with existing methods.

Storage Life Estimation of Magnesium Flare Material for 81 mm Illuminating Projectile (81 mm 조명탄용 마그네슘계 조명제 저장수명 예측)

  • Back, Seungjun;Son, Youngkap;Lim, Sunghwan;Myung, Inho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.267-274
    • /
    • 2015
  • It is necessary to both analyze root-cause of non-conformance of effective illumination time to the specification, and estimate the storage lifetime for 81 mm illuminating projectile stockpiled over 10 years. In this paper, aging mechanism of magnesium flare material due to long-term storage was supposed, and two-stage tests, pre-test and main test based on accelerated degradation tests were performed. Field storage environment of moistureproof was set up, and illumination times in the accelerated degradation tests for temperatures 60 and $70^{\circ}C$ were measured. Then, storage reliability of the projectile was estimated through analyzing the measured data and applying distribution-based degradation models to the data. The $B_{10}$ life by which 10 % of a population of the projectiles will have failed at storage temperature of $25^{\circ}C$ was estimated about 7 years.

Numerical Analysis on Thermal-Induced Degradation of n-i-p Structure Perovskite Solar Cells Using SCAPS-1D (SCAPS-1D 시뮬레이션을 이용한 n-i-p 구조 페로브스카이트 태양전지의 열적 열화 원인 분석)

  • Kim, Seongtak;Bae, Soohyun;Jeong, Younghun;Han, Dong-Woon;Kim, Donghwan;Mo, Chan Bin
    • Current Photovoltaic Research
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2022
  • The long-term stability of PSCs against visual and UV light, moisture, electrical bias and high temperature is an important issue for commercialization. In particular, since the operation temperature of solar cell can rise above 85℃, a study on thermal stability is required. In this study, the cause of thermal-induced degradation of PSCs was investigated using the SCAPS-1D simulation tool. First, PSCs of TiO2/CH3NH3PbI3/Spiro-OMeTAD/Au structure were exposed to a constant temperature of 85℃ to observe changes in conversion efficiency and quantum efficiency. Because the EQE reduction above 500 nm was remarkable, we simulated PSCs performance as a function of lifetime, doping density of perovskite and spiro-OMeTAD. Consequently, the main cause of thermal-induced degradation is considered to be the change in the perovskite doping concentration and lifetime due to ion migration of perovskite.

Effects of F-treatment on the Degradation of $Mg_2$Ni type Hydrogen Storage Alloy Electrode ($Mg_2$Ni계 수소저장합금전극의 퇴화거동에 미치는 불화 처리 영향)

  • Kim, Jun-Seong;Choe, Jae-Ung;Lee, Chang-Rae;Gang, Seong-Gun
    • Korean Journal of Materials Research
    • /
    • v.11 no.4
    • /
    • pp.294-299
    • /
    • 2001
  • Effects of the surface fluorination on the electrochemical charge-discharge properties of $Mg_2$Ni electrode in Ni-MH batteries fabricated by mechanical alloying were investigated. After 20h ball milling, Mg and Ni powder formed nanocrystalline $Mg_2$Ni. Discharge capacity of this alloy increased greatly at first one cycle, but due to the formation of Mg(OH)$_2$ passive layer, it showed a rapid degradation in alkaline solution within 10cyc1es. In case of 6N KOH +xN KF electrolyte (x = 0.5, 1, 2), a continuous and stable fluorinated layer formed by adding excess F$^{[-10]}$ ion, increased durability of $Mg_2$Ni electrode greatly and high rate discharge capability(90-100mAh/g). 2N KF addition led to the highest durability of all tested here. The reason of the improvement is due to thin MgF$_2$, which can prevent the $Mg_2$Ni electrode from forming Mg(OH)$_2$layer that is the main cause of degradation.

  • PDF

Performance Degradation of Mea with Cation Contamination in Polymer Electrolyte Membrane Water Electrolysis (고분자 전해질막 수전해 막전극접합체의 양이온 오염에 따른 성능 저하)

  • JUNG, HYEYOUNG;CHOI, NAKHEON;IM, SUHYUN;YOON, DAEJIN;MOON, SANGBONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.331-337
    • /
    • 2017
  • Proton Exchange Membrane Water Electrolysis (PEMWE) is one of the most popular and widely used methods for hydrogen production. PEMWE contributes to eco-friendly system via its energy storage system application, hence making it environmentally friendly to use. However, its main drawback is contamination of proton exchange membrane during water electrolysis. Existing cation such as magnesium, calcium and the likes are the cause for membrane contamination. As a result, the cation contamination give rise to degradation of performance of electrolysis and the reverse electrolysis is effective method to remove cation.