• Title/Summary/Keyword: Maiko

Search Result 10, Processing Time 0.024 seconds

A Study on Geisha's Dress Expressions in the Movie Focused on (영화 <게이샤의 추억>을 중심으로 본 게이샤복식 표현에 관한 연구)

  • Kim, Hee-Jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.10 no.1
    • /
    • pp.25-44
    • /
    • 2008
  • Geisha's gorgeous kimonos and grotesque make-up was the object of envy to Japanese women. There is a line in the movie like "Kimonos to the Geisha is the same as colors to the painter." Likewise, splendid patterns and colorful kimonos were an indispensible method or symbol for showing their artistic accomplishments. The purpose of this study is to investigate concept and origin of Geisha and their dress and decoration, analyze the dress of the people which appear in the movie, , arrange the expression of Geisha's dress as a movie costume, compare the difference of the dress by the career of Geisha and look back the disappearing aesthetic sense of Geisha. First, since Geisha appeared for the first time in Kyoto in 1751, it has become the world-wide representative of Japanese woman's images so that its existence oneself has become the tradition. Second, Geisha created fashion of various clothes, adornments, and hair styles as a creator of the popularity. Third, the strict regulation without exception is applied in Geisha's clothing, make-up, and motion tuned Samisen, Japanese traditional strings, and there is some difference in their hair style and dress by age of Maiko. Fourth, it is famous for unique make-up that Geisha makes up their faces, necks, and shoulders white, newly paints eyes, nose, lip line like drawing a picture in a pure white paper. Geishas put a little make-up as they have a higher position. Fifth, a heroin, Chiyo, shows clothing as a maid, an apprentice Geisha-Maiko- and a formal Geisha according to time flow. The length of kimono, textures, and hair decorations are longer, more splendid, and are more various as time goes. On the other hand, her make-up is lighter.

  • PDF

Interface formation between tris-(8-hydroxyquinoline) aluminum and room temperature stable electride: C12A7:$e^-$

  • Kim, Ki-Beom;Kikuchi, Maiko;Miyakawa, Masashi;Yanagi, Hiroshi;Kamiya, Toshio;Hirano, Masahiro;Hosono, Hideo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.235-238
    • /
    • 2006
  • Interface formation between $12CaO{\cdot}7Al_2O_3(C12A7:e^-)$ and Alq3 was investigated using in-situ ultra-violet photoelectron spectroscopy (UPS) and X-ray photoelectron spectroscopy (XPS). The work function and vacuum level shift of $C12A7:e^-$ were change by different surface treatment from 2.6eV to 4.2eV. Also vacuum level shift $(\Delta)$ at the interface were from +0.3eV to -0.3eV.

  • PDF

Computer programme to assess mandibular cortex morphology in cases of medication-related osteonecrosis of the jaw with osteoporosis or bone metastases

  • Ogura, Ichiro;Kobayashi, Eizaburo;Nakahara, Ken;Haga-Tsujimura, Maiko;Igarashi, Kensuke;Katsumata, Akitoshi
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.281-286
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the morphology of the mandibular cortex in cases of medication-related osteonecrosis of the jaw (MRONJ) in patients with osteoporosis or bone metastases using a computer programme. Materials and Methods: Fifty-four patients with MRONJ (35 with osteoporosis and 19 with bone metastases) were examined using panoramic radiography. The morphology of the mandibular cortex was evaluated using a computer programme that scanned the mandibular inferior cortex and automatically assessed the mandibular cortical index (MCI) according to the thickness and roughness of the mandibular cortex, as follows: normal (class 1), mildly to moderately eroded (class 2), or severely eroded (class 3). The MCI classifications of MRONJ patients with osteoporosis or bone metastases were evaluated with the Pearson chi-square test. In these analyses, a 5% significance level was used. Results: The MCI of MRONJ patients with osteoporosis(class 1: 6, class 2: 15, class 3: 14) tended to be higher than that of patients with bone metastases(class 1: 14, class 2: 5, class 3: 0)(P=0.000). Conclusion: The use of a computer programme to assess mandibular cortex morphology may be an effective technique for the objective and quantitative evaluation of the MCI in MRONJ patients with osteoporosis or bone metastases.

Can proximal Gastrectomy Be Justified for Advanced Adenocarcinoma of the Esophagogastric Junction?

  • Sato, Yuya;Katai, Hitoshi;Ito, Maiko;Yura, Masahiro;Otsuki, Sho;Yamagata, Yukinori;Morita, Shinji
    • Journal of Gastric Cancer
    • /
    • v.18 no.4
    • /
    • pp.339-347
    • /
    • 2018
  • Purpose: To evaluate the status of number 3b lymph node (LN) station in patients with adenocarcinoma of the esophagogastric junction (AEG) and to investigate the optimal indications for radical proximal gastrectomy (PG) for AEG. Materials and Methods: Data of 51 patients with clinically advanced Siewert types II and III AEG who underwent total gastrectomy (TG) between April 2010 and July 2017 were reviewed. The proportion of metastatic LNs at each LN station was examined. Number 3 LN station was separately classified into number 3a and number 3b. The risk factors for number 3b LN metastasis and the clinicopathological features of number 3b-positive AEG patients were investigated. Results: The incidences of LN metastasis were the highest in number 1 (47.1%), followed by number 2 (23.5%), number 3a (39.2%), and number 7 (23.5%) LN stations. LN metastasis in number 3b LN station was detected in 4 patients (7.8%). A gastric invasion length of more than 40 mm was a significant risk factor for number 3b LN metastasis. All 4 patients with number 3b-positive AEG had advanced cancer with a gastric invasion length of more than 40 mm. The 5-year survival rate of patients with a gastric invasion length of more than 40 mm was 50.0%. Conclusions: Radical PG may be indicated for patients with AEG with gastric invasion length of less than 40 mm.

CBCT imaging and histopathological characteristics of osteoradionecrosis and medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Minami, Yoshiyuki;Ono, Junya;Kanri, Yoriaki;Okada, Yasuo;Igarashi, Kensuke;Haga-Tsujimura, Maiko;Nakahara, Ken;Kobayashi, Eizaburo
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.73-80
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the cone-beam computed tomographic (CBCT) imaging and histopathological characteristics of osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Ten surgical specimens from segmental mandibulectomy (3 ORN and 7 MRONJ) were analyzed using CBCT. The CBCT parameters were as follows: high-resolution mode (tube voltage, 90.0 kV; tube current, 4.00 mA; rotation time, 16.8 s; field of view, 56 mm×56 mm; thickness, 0.099 mm). Histopathological characteristics were evaluated using histological slides of the surgical specimens. The Pearson chi-square test was used to compare ORN and MRONJ in terms of CBCT findings(internal texture, sequestrum, periosteal reaction and cortical perforation) and histopathological characteristics(necrotic bone, inflammatory cells, reactive bone formation, bacteria, Actinomyces, and osteoclasts). A P value less than 0.05 was considered to indicate statistical significance. Results: MRONJ showed periosteal reaction on CBCT more frequently than ORN (7 of 7 [100%] vs. 0 of 3 [0%], P<0.05). Regarding histopathological characteristics, MRONJ showed osteoclasts more frequently than ORN (6 of 7 [85.7%] vs. 0 of 3 [0%], P<0.05). Conclusion: This study evaluated the CBCT imaging and histopathological characteristics of ORN and MRONJ, and the findings suggest that CBCT could be useful for the evaluation of ORN and MRONJ.

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

Feline Herpes Virus-1 Associated Facial and Perianal Dermatitis in a Cat (고양이 헤르페스 바이러스-1 감염과 관련된 고양이의 안면 및 회음부 피부염)

  • Yoon, Ji-Seon;Yabuzoe, Astushi;Sekiguchi, Maiko;Park, Jinho;Iwasaki, Toshiroh;Nishifuji, Koji
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.210-213
    • /
    • 2013
  • We herein describe a feline case of facial dermatitis whose histopathological features resembled to those of FHV-associated ulcerative dermatitis. A 3-year-old, intact male domestic short-haired cat was presented with 2-years history of pruritic dermatitis that initially appeared on periocular area and extended toward the entire face. The cat had ocular discharge and conjunctivitis from 2-month of age. Clinically, skin lesions were characterized as erythema, erosions and ulcers covered with crusts on the facial and perianal area. Histopathologically, the facial lesion was characterized as interface dermatitis with hydropic degeneration at the basal layer, and single cell necrosis of keratinocytes. In addition, the epidermal and dermal necrosis infiltrated with eosinophils, and intranuclear inclusion bodies in keratinocytes were also recognized. Moreover, feline herpesvirus-1 gene was detected by a PCR analysis using a swab obtained from the crusted lesions. Based upon these findings, the present case was considered as having FHV-associated ulcerative dermatitis. Therapy including oral acyclovir and topical recombinant feline interferon omega resulted in marked improvement of the skin and mucosal lesions.

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.