• Title/Summary/Keyword: Magnitude factor

Search Result 545, Processing Time 0.025 seconds

Static VAR Compensator Using PWM Voltage type Converter (PWM전압형 콘버어터에 의한 정지형 무효전력 보상장치)

  • 정연택;이훈구;황락훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.836-846
    • /
    • 1990
  • This paper presents a Static Var Compensator (SVC) system compensating the reactive power for power system, which consists of a voltage type Pulse Width Modulation (PWM) converter and a reactance linking the converter to the source. The system drives the four quadrant modes. The system determines the magnitude of the input voltage, and then compares it with the magnitude of the source voltage by regulating the phase of the SVC about the source. Therefore, the system generates leading compensation currents when the input voltage is larger than the source in magnitude, and lagging compensation currents for smaller input voltage. Reactive power about voluntary load in power system is smoothly compensated by those compensation currents, and also power factor of source is improved. Furthermore, the SVC system using PWM method may improve the source current waveforms by eliminating the 5th and 7th harmonic components from the input voltages.

  • PDF

Analysis of Voltage Regulation by DSTATCOM - Using the EMTDC Program

  • Jeon Young-Soo;Kwak No-Hong;Choo Jin-Boo
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.329-334
    • /
    • 2005
  • The DSTATCOM(Distribution Static Synchronous Compensator) is one of the Custom Power Devices that can regulate voltage. The DSTATCOM operates as a shunt connected static var compensator whose capacitive or inductive output current can be controlled independent of the system voltage. The magnitude of the compensated voltage is limited by characteristics of the system and the load. Compensation capability of the DSTATCOM which can inject 1 MVAR reactive power was simulated by EMTDC under several conditions. This paper analyzes the effect of the DSTATCOM's compensation considering the length and kind of distribution line, the power factor and magnitude of the load, and the duration and magnitude of the voltage variation.

Effect of limestone calcined clay cement (LC3) on the fire safety of concrete structures

  • Gupta, Sanchit;Singh, Dheerendra;Gupta, Trilok;Chaudhary, Sandeep
    • Computers and Concrete
    • /
    • v.29 no.4
    • /
    • pp.263-278
    • /
    • 2022
  • Limestone calcined clay cement (LC3) is a low carbon alternative to conventional cement. Literature shows that using limestone and calcined clay in LC3 increases the thermal degradation of LC3 pastes and can increase the magnitude of fire risk in LC3 concrete structures. Higher thermal degradation of LC3 paste prompts this study toward understanding the fire performance of LC3 concrete and the associated magnitude of fire risk. For fire performance, concrete prepared using ordinary Portland cement (OPC), pozzolanic Portland cement (PPC) and LC3 were exposed to 16 scenarios of different elevated temperatures (400℃, 600℃, 800℃, and 1000℃) for different durations (0.5 h, 1 h, 2 h, and 4 h). After exposure to elevated temperatures, mass loss, residual ultrasonic pulse velocity (rUPV) and residual compressive strength (rCS) were measured as the residual properties of concrete. XRD (X-ray diffraction), TGA (thermogravimetric analysis) and three-factor ANOVA (analysis of variance) are also used to compare the fire performance of LC3 with OPC and PPC. Monte Carlo simulation has been used to assess the magnitude of fire risk in LC3 structures and devise recommendations for the robust application of LC3. Results show that LC3 concrete has weaker fire performance, with average rCS being 11.06% and 1.73% lower than OPC and PPC concrete. Analysis of 106 fire scenarios, in Indian context, shows lower rCS and higher failure probability for LC3 (95.05%, 2.22%) than OPC (98.16%, 0.22%) and PPC (96.48%, 1.14%). For robust application, either LC3 can be restricted to residential and educational structures (failure probability <0.5%), or LC3 can have reserve strength (factor of safety >1.08).

A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load (선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

An Efficient Peak Detection Algorithm in Magnitude Spectrum for M-FSK Signal Classification (M-FSK 변조 신호 분류를 위한 효율적인 진폭 스펙트럼의 첨두 검출 방법)

  • Ahn, Woo-Hyun;Seo, Bo-Seok
    • Journal of Broadcast Engineering
    • /
    • v.19 no.6
    • /
    • pp.967-970
    • /
    • 2014
  • An efficient peak detection algorithm in magnitude spectrum is proposed to distinguish the M-frequency shift keying(FSK) signals from other digitally modulated signal. In addition, recognition of the modulation order estimation of FSK signals is also studied based on the fact that the magnitude spectrum of FSK signals reveals the number of peaks equal to the modulation order. When no a priori information about the signals, we utilize the histogram of the magnitude spectrum to determine the threshold which is important factor in peak detection algorithm. The simulation results show high probability of classification under 500 symbols and signal-to-noise ratio(SNR) higher than 4dB.

Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter (PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

A New Control Algorithm for Instantaneous Voltage Sag Corrector (순시전압강하 보상기의 새로운 제어 기법)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어)

  • Yang, Lee-U;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

Vibration control of elastic systems (탄성계의 진동제어)

  • 박영필;이상조
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.113-118
    • /
    • 1986
  • The feedback controllers for the active vibration control of elastic systems are developed using optimal regulator, optimal tracking, time optimal and noise observer algorithms. Using the modal analysis of the elastic systems, the effects of the actuator positions, the input weighting factor and the magnitude of the constraint of the actuator force are investigated.

  • PDF

Study on quantization of Korean medicine terminology concept - for disease symptom terms of Compilation of Formulas and Medicinals Addendum - (한의학 용어 개념의 정량화 연구 - 방약합편의 병증 용어를 대상으로 -)

  • Lee, Jeong-Hyeon;Kim, Wu-Yong;Oh, Junho
    • Journal of Korean Medical classics
    • /
    • v.27 no.1
    • /
    • pp.99-109
    • /
    • 2014
  • Objectives : The concepts of many Korean medicine terms have changed for a long time and cumulatively been recorded in later medicine literatures. And, the same terms have very often been used for different meanings depending on context. Methods : This study was performed so that conceptual magnitude of Korean medicine terms could intuitively be recognized for the purpose of quantization. Results : This study was performed under the premise that terms used in old literatures of Korean medicine are related mostly to treatments that could immediately be reverted to types of medical herbs used. Through this, conceptual magnitude of terms was quantified by the method that frequency of medical herbs used for treatment was changed to numerical values. For this, data of "Compilation of Formulas and Medicinals Addendum" were used. First, after 'specificity' of each medicine herb corresponding to representative disease symptoms was calculated, medians in the set were selected, and 'values of conceptual magnitude' for representative disease symptoms were calculated. Conclusions : As a result, if disease symptoms are diverse, concept range is diachronically changed greatly, and specific disease symptoms of great conceptual difference are included, value of conceptual magnitude was great. Meanwhile, if disease factor and treatment are singular or limited to several types, and many medical herbs with high specificity are used, value of conceptual magnitude was less.