• Title/Summary/Keyword: Magnification of image

Search Result 190, Processing Time 0.032 seconds

3D Image Correlator using Computational Integral Imaging Reconstruction Based on Modified Convolution Property of Periodic Functions

  • Jang, Jae-Young;Shin, Donghak;Lee, Byung-Gook;Hong, Suk-Pyo;Kim, Eun-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.388-394
    • /
    • 2014
  • In this paper, we propose a three-dimensional (3D) image correlator by use of computational integral imaging reconstruction based on the modified convolution property of periodic functions (CPPF) for recognition of partially occluded objects. In the proposed correlator, elemental images of the reference and target objects are picked up by a lenslet array, and subsequently are transformed to a sub-image array which contains different perspectives according to the viewing direction. The modified version of the CPPF is applied to the sub-images. This enables us to produce the plane sub-image arrays without the magnification and superimposition processes used in the conventional methods. With the modified CPPF and the sub-image arrays, we reconstruct the reference and target plane sub-image arrays according to the reconstruction plane. 3D object recognition is performed through cross-correlations between the reference and the target plane sub-image arrays. To show the feasibility of the proposed method, some preliminary experiments on the target objects are carried out and the results are presented. Experimental results reveal that the use of plane sub-image arrays enables us to improve the correlation performance, compared to the conventional method using the computational integral imaging reconstruction algorithm.

An efficient quality improvement scheme of magnified image by using the information of adjacent pixel values (인접 픽셀 값 정보를 이용하는 효율적인 확대 영상의 화질 개선 기법)

  • Jung, Soo-Mok;On, Byung-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.2
    • /
    • pp.49-57
    • /
    • 2013
  • To improve the quality of magnified image, two schemes were proposed. The one is used to estimate simple convex surface and simple concave surface using the information of adjacent pixel values, and the other scheme is used to produce magnified image using the characteristics of simple convex surface and simple concave surface. The magnified image using the proposed scheme is more similar to real image than the magnified image using the previous schemes. The PSNR values of the magnified images using the proposed scheme are greater than those of the magnified images using the previous interpolation schemes.

Analysis of performance changes based on the characteristics of input image data in the deep learning-based algal detection model (딥러닝 기반 조류 탐지 모형의 입력 이미지 자료 특성에 따른 성능 변화 분석)

  • Juneoh Kim;Jiwon Baek;Jongrack Kim;Jungsu Park
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.267-273
    • /
    • 2023
  • Algae are an important component of the ecosystem. However, the excessive growth of cyanobacteria has various harmful effects on river environments, and diatoms affect the management of water supply processes. Algal monitoring is essential for sustainable and efficient algae management. In this study, an object detection model was developed that detects and classifies images of four types of harmful cyanobacteria used for the criteria of the algae alert system, and one diatom, Synedra sp.. You Only Look Once(YOLO) v8, the latest version of the YOLO model, was used for the development of the model. The mean average precision (mAP) of the base model was analyzed as 64.4. Five models were created to increase the diversity of the input images used for model training by performing rotation, magnification, and reduction of original images. Changes in model performance were compared according to the composition of the input images. As a result of the analysis, the model that applied rotation, magnification, and reduction showed the best performance with mAP 86.5. The mAP of the model that only used image rotation, combined rotation and magnification, and combined image rotation and reduction were analyzed as 85.3, 82.3, and 83.8, respectively.

Quantitative localization of impacted mesiodens using panoramic and periapical radiographs

  • Choi, Hang-Moon;Han, Jin-Woo;Park, In-Woo;Baik, Jee-Seon;Seo, Hyun-Woo;Lee, Joo-Hyun;Park, Ho-Won
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate a new technique for localizing impacted mesiodens using its horizontal magnification ratio on panoramic radiographs. Materials and Methods : Location-magnification equation of a panoramic equipment was obtained from horizontal magnification ratio of a metal ball which was located variable positions from the center of image layer at interval of 2 mm. Panoramic radiographs were obtained from a skull phantom with a metal ball which was a substitute for impacted mesiodens and was embedded 10mm(Group 1), 15mm(Group 2), and 20mm(Group 3) posterior to the central incisor. Each group obtained 7 panoramic radiographs at variable positions and one periapical radiograph. Three methods were used to estimate the actual width of the incisors and the balls which were used to calculate the magnification ratio. The methods included using the actual incisor width and the calculated ball width (Method 1), using the actual incisor width and the ball widths measured on periapical radiograph (Method 2), and using the incisor and the ball widths measured on periapical radiograph (Method 3). The location of the metal ball was calculated by using the location-magnification equation. Results : The smallest difference between the calculated and the actual distance was $0.1{\pm}0.7 \;mm$ in Group 1/ Method 3. The largest difference was $-4.2{\pm}1.6 \;mm$ in Group 3/Method 2. In all groups, method 3 was the most accurate. Conclusion : Quantitative localization of impacted mesiodens is possible by using panoramic radiograph.

Design of a PIV objective maximizing the image signal-to-noise ratio

  • Chetelat Olivier;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.123-137
    • /
    • 2001
  • PIV (particle image velocimetry) systems use a camera to take snapshots of particles carried by a fluid at some precise instants. Signal processing methods are then used to compute the flow velocity field. In this paper, the design of the camera objective (optics) is addressed. The optimization is done in order to maximize the signal-to-noise ratio of in-focus particles. Four different kinds of noise are considered: photon shot noise, thermal and read noise, background glow shot noise, and noise made by the other particles. A semi-empirical model for the lens aberrations of a two-doublet objective is first addressed, since further, it is shown that lens aberrations (low f-value $f_{\#}$) should be used instead of the Fraunhofer diffraction (high f-value) for the fitting of the particle image size with the pixel size. Other important conclusions of the paper include the expression of optimum values for the magnification M, for the exposure period $\tau$ and for the pixel size $\xi$.

  • PDF

Development of an Optical System for Iris Photographing (홍채 촬영용 광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2003
  • We tried to design and manufacture an iris photographing optical-system which is used in the Oriental medicine or medical diagnostics. The whole system consists of a light source part, an image focusing part, a CCD transfer part and a diagnosis S/W. We designed the image focusing part to the reduction optical-system with 0.58X magnification of which the chromatic aberration is removed by using materials of FD60 and BACD5. The image focusing part's localization did big contribution in coot reduction of products. The manufactured iris photographing optical-system had superior performance in aspect that has stereoscopic effects of images in comparison with the foreigner's.

  • PDF

A study on compensation of distorted 3D depth in the triple fresnel lenses floating image system

  • Lee, Kwnag-Hoon;Kim, Soo-Ho;Yoon, Young-Soo;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1490-1493
    • /
    • 2007
  • We proposed the method to take 3D image having correct depths to the front and rear directions when the stereogram was displayed to an observer through an optical system. Since the magnified stereogram by lenses was not given correct depth to an observer despite having the same magnified disparity. Consequently, we achieved our goal by relations of compensated disparities to both directions with magnification of lenses, viewing distance and base distance of viewer in AFIS.

  • PDF

Fast Zooming and Focusing Technique for Implementing a Real-time Surveillance Camera System (실시간 감시 카메라를 구현하기 위한 고속 영상확대 및 초점조절 기법)

  • 한헌수;최정렬
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.74-82
    • /
    • 2004
  • This paper proposes a fast zooming and focusing technique for implementing a real-time surveillance camera system which can capture a face image in less than 1 second. It determines the positions of zooming and focusing lenses using two-step algorithm. In the first step, it moves the zooming and focusing lenses simultaneously to the positions calculated using the lens equations for achieving the predetermined magnification. In the second step the focusing lens is adjusted so that it is positioned at the place where the focus measure is the maximum. The camera system implemented for the experiments has shown that the proposed algorithm spends about 0.56 second on average fur obtaining a focused image.

THE STRUCTURE OF THE MANDIBULAR CONDYLE IN THE PANORAMIC RADIOGRAPH (파노라마방사선 사진에서의 하악과두구조)

  • Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.163-167
    • /
    • 1990
  • The author has evaluated the panoramic image of the mandibular condyle according to its horizontal condylar angle (0˚, 10˚, 20°, 30°, 40°) and mandibular position (standard, 25㎜ forward and reverse position). The results were as follows: 1. The larger the horizontal condylar angle was, the larger the horizontal magnification was in all positions. 2. In case of small horizontal condylar angle, profile view could be obtained in 25㎜ forward and reverse position. 3. In case of large horizontal condylar angle, profile view could not be obtained in any positions.

  • PDF

Development of Measuring System for Camera Lens Resolution Based on the MTF Performance (MTF 측정에 의한 카메라 렌즈 해상력 검사 시스템 개발)

  • 박희재;신호승;노영훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.629-634
    • /
    • 2000
  • This System is developed for the estimation of the Camera Lens Resolution. Signal data proportional to light intensity is obtained and sampled from the 2D CCD. Based on the measured signal. the MTF charateristcs of a camera lens are measured. We could measure the sagittal and tangential MTF in the on and off-axis at the same time. The automatic measurig methods for optimal image plane, magnification, and best marginal direction of test lens are presented.

  • PDF