• 제목/요약/키워드: Magnetostrictive actuator

검색결과 48건 처리시간 0.026초

자기변형소자를 이용한 선형 액츄에이터의 제작 및 실험 (Fabrication and experiment of the linear magnetostrictive actuator with electromagnetic clamp)

  • 김병호;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.419-421
    • /
    • 1994
  • A linear actuator using Terfenol-D rod which can accumulate displacement of the rod was fabricated. The diameter of used rod is 12[mm] and the length of it is 75[mm]. It adopts the electromagnetic units as the clamping units. Basic characteristics of the linear actuator such as displacement vs. current, velocity vs. frequency, step size vs. frequency were experimented. When the driving current is 1[A] and 100[Hz], the velocity of the actuator is about 3.5[mm/s]. We discussed the cause of step size's decrease as increasing driving frequency and the solution to the problem.

  • PDF

박막성형 기술 및 MEMS 공정을 이용한 자기변형 위치변환기 (Fabrication of a Magnetostrictive Transpositioner using Thin Film Deposition and MEMS Techniques)

  • 이흥식;조종두;이상교
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1617-1620
    • /
    • 2007
  • This paper presents a magnetostrictive transpositioner and its fabrication process. To get a transposition movement without shifting or twisting, it is designed as an array type. To fabricate the suggested design, micromachining and selective DC magnetron sputtering processes are combined. TbDyFe film is sputter-deposited on the back side of the bulk micromachined transpositioner, with the condition as: Ar gas pressure below $1.2{\times}10^{-9}$ torr, DC input power of 180W and heating temperature of up to $250^{\circ}C$ for the wireless control of each array component. After the sputter process, magnetization and magnetostriction of each sample are measured. X-ray diffraction studies are also carried out to determine the film structure and thickness of the sputtered film. For the operation, each component of the actuator has same length and out-of-plane motion. Each component is actuated by externally applied magnetic fields up to 0.5T and motion of the device made upward movement. As a result, deflections of the device due to the movement for the external magnetic fields are observed.

  • PDF

초자왜소자의 자왜 특성의 측정 (Measurement of the Magnetostrictive Properties of Giant Magnetostrictive Alloy)

  • 백창욱;김용권
    • 한국자기학회지
    • /
    • 제4권4호
    • /
    • pp.303-306
    • /
    • 1994
  • 본 논문에서는 초자왜소자 $Terfenol-D(Tb_{0.3}Dy_{0.7}Fe_{1.9~1.95})$의 인가자장에 따른 자왜의 변화를 측정하였고, 잔류 자왜 및 초자왜소자의 온도 상승에 의한 열팽창 변형의 영향을 조사 하였다. 또한 초자왜소자에 3.5~14 MPa의 압축 응력을 인가하면서 자왜의 변화를 조사하였다. 그 결과는 인 가 압축 응력이 7 MPa인 경우 1500 Oe의 자장에서의 자왜는 1000 ppm이었으나 압축 응력을 가하지 않은 경 우는 400 ppm이었다. 또한 인가 압축 응력이 커짐에 따라서 자왜가 포화되는 자장의 크기도 커졌다. 잔류 변형과 히스테리시스가 관측되었으며, 따라서 액츄에이터로 이용할 때는 이를 보상하는 기구가 필요하며 또 한 열팽창에 의한 변형도 액츄에이터 응용시에는 고려하여야 한다.

  • PDF

자기변형재료를 이용한 절삭공구용 마이크로포지쇼너의 개발

  • 박영우;원문철
    • 한국정밀공학회지
    • /
    • 제15권3호
    • /
    • pp.75-81
    • /
    • 1998
  • In the machining process, variation in cutting forces results in relative displacements between the tool and the workpiece leading to tool vibration. Also there is a demand to change the depth of cut very frequently. One solution for the both cases is to develop a system which has the ability to reposition a cutting tool to a very small level, i.e., micron. This paper presents the development of a micropositioner using a magnetostrictive material. The developed micropositioner is implemented to a lathe and subjected to various tests. The results show that the micropositioner with a magnetostrictive actuator has good potential for machining application.

  • PDF

자기변형 마이크로 작동기의 설계 (Design of a Magnetostrictive MicroActuator)

  • 김도연;박영우;임민철
    • 한국정밀공학회지
    • /
    • 제21권5호
    • /
    • pp.174-181
    • /
    • 2004
  • This paper presents the development of a magnetostrictive microactuator. The structural and functional requirements are as follows: it must be a millimeter structure and must achieve controllable displacement with nanometer resolution. Finite Element Analysis(FEA) is used to determine the structure with the most uniform and highest magnetic flux density along the Terfenol-D rod. The microactuator prototype 1 is designed and made based on the FEA. It is observed that the microactuator show some level of hysteresis and that it produces 25 newton in force and 3 ${\mu}{\textrm}{m}$ in displacement with 1.5 amperes of current, and resolution of 250 nm per 0.1 amperes. To improve the performance of the microactuator prototype 1, microactuator prototype 2 is made again with a permanent magnet (PM). It is observed that the microactuator prototype 2 gene.ates 3.3 ${\mu}{\textrm}{m}$ in displacement with 0.9 amperes of current. It means that the microactuator prototype 2 performs better than the microactuator prototype 1.

FeCoGe/페놀 복합체의 정적 자기변형 측정 (Static measurement of magnetostriction of FeCoGe/phenol composites)

  • 박경일;나석민;신광호;임상호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.577-580
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites, which is one of the magnetostrictive materials, measured at the external magnetic field. The measurement was carried out using the electrical-resistance strain gage, the wheaten's Bridge for eliminating the unnecessary voltage, and the lock-in-amp for signal amplification and noise filtering. When the external magnetic field was applied in the longitudinal the samples, the maximum strain of 120ppm was taken with regard to the 10wt.% phenol composite. This results indicate that the FeCoGe/phenol composites can be useful as an actuator because it has larger stain than the other solid state actuators such as piezo electric materials.

  • PDF

대변위-고정밀 위치제어를 위한 자기변형 self-moving cell 선형모터 (Magentostrictive self-moving cell linear motor for displacement control with large force and high resolution)

  • 두재균;김재환;최승복;박홍근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.249-255
    • /
    • 2000
  • The design and test of an magnetostrictive linear motor(MLM) that operates based on self-moving cell concept is presented. The moving cell is composed of Terfenol-D linear actuator and a ring structure, and a cell train is constructed by connecting two cells in series. Since this motor uses the stroke of Terfenol-D actuators and friction force of the cells, it can essentially produce long stroke and large force. The overall performance of the MLM was measured in terms of speed and force. The pushing force is directly related with the friction force. This work is a proof-of-concept stage and investigation is necessary for realistic application.

  • PDF