• Title/Summary/Keyword: Magnetizing inductance

Search Result 83, Processing Time 0.023 seconds

A Hybrid DC/DC Converter for EV OBCs Using Full-bridge and Resonant Converters with a Single Transformer

  • Hassan, Najam ul;Kim, Yoon-Jae;Han, Byung-Moon;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • This paper proposes a dc/dc converter for electric vehicle onboard chargers using a secondary resonant tank. To attain soft switching characteristics, such as zero voltage switching, magnetizing inductance has been used at the primary side of the transformer. The leakage inductance of the transformer is used as a resonant inductor on the secondary side to avoid the use of a separate inductor as resonance. The proposed converter is applicable for a wide load range. A 6.6KW prototype has been implemented for a wide range of load variations (250V, 330V, 360V, and 413V). A maximum efficiency of 97.4% is achieved at 413V.

Parameters Estimation and Torque Monitoring for the Induction Spindle Motor (주축용 유도전동기의 매개변수 추정과 토크 모니터링 시스템)

  • Kwon, Won-Tae;Kim, Gyu-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.238-244
    • /
    • 2004
  • To monitor the torque of an induction motor using current, the accurate identification of the motor parameters is very important. In this study, the motor parameters such as rotor resistance, stator and rotor leakage inductance, mutual inductance are estimated for torque monitoring and indirect vector control. Estimated parameters are used to monitor the torque of vector controlled induction motor without any speed measuring sensor. Stator current is measured to estimate the magnetizing current which is used to calculate flux linkage, rotor velocity and motor torque. From the experiments, the proposed method shows a good estimation of the motor parameters and torque under the normal rotational speed.

Numerical Analysis and Design of Moving Contactless High Power Transformer

  • Lee, Dong-Su;Jang, Dong-Uk;Kim, Hyung-Chul;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.423-426
    • /
    • 2011
  • This paper presents numerical analysis and design of high power contactless transformer with a large air-gap for moving on a guided linear track which is appropriate for high-speed train or MAGLEV. The system has the typical characteristics of large leakage inductance, small magnetizing inductance, and low coupling coefficients giving rise to lower power transfer efficiency, which have been compensated by the purposely-designed contactless transformer coupled with the resonant converter modulating with high switching frequency. In particular, the best model selected from the generated six design candidates has been applied for 3D Finite Element Analysis (FEA) investigating on iron loss to evaluate the overall system efficiency.

A Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging (비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계)

  • Kim, Young-Gil;Na, Hee-Su;Kim, Jin-Woo;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1300-1302
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter. In this paper magnetizing inductance, leakage inductance and coupling coefficient, k are observed. By using the obserbed value, the proposed circuit is simulated by the PSPICE and implemented and the peak voltage of switch and output power are measured.

  • PDF

Maximum Power Control of IPMSM Considering Nonlinear Cross-Magnetization Effects

  • Kim, Youn-Hyun;Kim, Won-Kyu;Kim, Sol
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.940-947
    • /
    • 2012
  • Interior permanent magnet synchronous motor is widening its application compared to other AC machines because of magnetic and reluctance torque. Despite of the advantages, improving control performance with parameter nonlinearity consideration is crucial during the field weakening control. This paper shows a maximum power control method at the field weakening region that considers d, q inductance's nonlinearity due to magnetic saturation and d, q mutual inductance. To verify the feasibility of control scheme, FEM simulations and experiments about comparison between linear and nonlinear maximum power control are carried out.

Effect Analysis of Magnet on Ld and Lq Inductance of Permanent Magnet Assisted Synchronous Reluctance Motor Using Finite Element Method (유한요소법을 이용한 영구자석 매입 동기형 릴럭턴스 전동기의 Ld, Lq 인덕턴스에 미치는 영구자석 특성분석)

  • Kim, Gi-Bok;Choi, Si-Hyun;Kwon, Sun-Bum;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1009-1011
    • /
    • 2003
  • This study investigates the characteristics of Permanent Magnet Assisted Synchronous Reluctance Motor (PMASynRM) using coupled FEM and Preisach modelling. The focus of this paper is the characteristics analysis of d, q axis inductance according to magnetizing direction and quantity of interior permanent magnet far PMASynRM. Investigation on nonlinear characteristic of machine is performed by Preisachs theory application. Comparisons are given with characteristics of normal Synchronous reluctance motor(SynRM) and those according to the quantity of residual flux density (0.3T and 0.4T) in PMASynRM, respectively.

  • PDF

Design and Characteristic Analysis Method of LOA (리니어 진동액튜에이터(LOA)의 설계 및 특성 해석법)

  • Jang, S.M.;Park, C.I.;Park, H.C.;Son, Y.S.;Kim, H.G.;Seo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.177-179
    • /
    • 1995
  • The hybrid type LOA is electric machine which reciprocates the mover by thrust force produced by interaction of flux between coil current and permanent magnet. In this paper, the shape of LOA is designed conceptually and calculating algorithm of leakage inductance in the stator slot and magnetizing inductance between stator and mover is obtained. Using the conceptually designed LOA, the change of flux distribution is studied in consideration with movement of a mover.

  • PDF

High Power Density 50kW Bi-directional Converter for Hybrid Electric Vehicle HDC (하이브리드 자동차용 HDC를 위한 50kW급 고전력밀도 양방향 컨버터)

  • Yang, Jung-Woo;Keum, Moon-Hwan;Choi, Yoon;Han, Sang-Kyoo;Kim, Seok-Joon;Kim, Sam-Gyun;Kim, Jong-Pil;Sakong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.95-101
    • /
    • 2016
  • This paper proposed a high-power density bidirectional converter for hybrid electric vehicle high-voltage DC-DC converter(HDC). The conventional HDC has two disadvantages. First, large inductance is required to satisfy the ripple current of inductor by low switching frequency (<20 kHz). Second, large core size is required to prevent the saturation of inductor by high current. Compared with the conventional HDC, the proposed HDC can reduce inductance with SiC-FET for high frequency driving. High-power density of I/O capacitors can be achieved through two-phase interleaved method. The high-power density of inductors can be achieved because the offset current of magnetizing inductance is theoretically terminated by using the differential mode coupled inductor instead of using two single inductors. The validity of the proposed converter is proved through the 50 kW prototype.

Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers (두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터)

  • Yoo, Doo-Hee;Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.497-507
    • /
    • 2010
  • This paper presents current unbalance improved half-bridge LLC resonant converter using the two transformers with different leakage inductances. The proposed converter resonates with the leakage inductance and magnetizing inductance of the transformer and the resonant capacitance. The converter operates in a wide load range and satisfies the zero voltage switching even under the light load. The series-parallel connected two transformers act as the transformers or the resonant inductances according to the operational modes, and the separate output filter inductance in the transformer secondary is not needed using the leakage inductance. The current unbalance of the secondary diode rectifier is improved using the different leakage inductances of the two transformers and the asymmetrical pulse-width modulation (PWM). In this paper, the operational principle of the converter is explained by the modes, and the design example for the prototype is also shown. To validate the performance of the converter, the prototype is implemented as the designed circuit parameters and the good performance of the proposed converter is shown through the experimental results

D-q Equivalent Circuit-based Protection Algorithm for a Doubly-fed Induction Generator in the Time Domain

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Lee, Ji-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.371-378
    • /
    • 2010
  • Most modern wind turbines employ a doubly-fed induction generator (DFIG) system due to its many advantages, such as variable speed operation, relatively high efficiency, and small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. We propose a protection algorithm for a DFIG based on a d-q equivalent circuit in the time domain. In the DFIG, the voltages and currents of the rotor side and the stator side are available. The proposed algorithm estimates the instantaneous induced voltages of magnetizing inductance using those voltages and currents from both the stator and the rotor sides. If the difference between the two estimated induced voltages exceeds the threshold, the proposed algorithm detects an internal fault. The performance of the proposed algorithm is verified under various operating and fault conditions using a PSCAD/EMTDC simulator.