• 제목/요약/키워드: Magnetizing current

검색결과 169건 처리시간 0.023초

등가회로를 이용한 100kW급 동기전동기 회전자의 착자 전류 산정 (Magnetizing Current Analysis of 100kW-class Permanent Magnet Synchronous Motor Rotor Using Equivalent Circuit)

  • 이정종;전찬기;유세현;정인성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.860-861
    • /
    • 2015
  • 본 논문에서는 대용량 착자요크의 설계과정에서 최대입력 전류의 크기를 산정하기 위하여 해석적인 방법을 이용하여 산정하였다. 착자요크의 등가회로로부터 회로방정식을 도출하고 2차 미분방정식으로 표현하여 입력전류를 산정하였다. 산정된 입력전류는 회로해석 툴 및 유한요소해석을 이용한 상용소프트웨어와 비교하여 해석방법의 타당성을 검증하였다.

  • PDF

Intelligent-CCS Fed Marine-Express Model Train ME03 in Mass-Reduced-Mode

  • Yoshida, Kinjiro;Takami, Hiroshi;Mehara, Hazime
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.944-949
    • /
    • 1998
  • This paper presents a new high-performance intelligent controlled current-source (CCS) system which can compensate for modelling errors of armature resistance, leakage and magnetizing inductances and for space harmonic components of speed EMF's. A shuttle-motion simulation is presented in the mass-reduced-mode in which an equivalent vehicle weight is reduced, by 40kg to 7kg. This study provides one of the most important key-tech-nologies in driving practical linear synchronous motor (LSM) Maglev vehicle.

  • PDF

낮은 도통손실을 가지며 넓은 영전압 스위칭 범위를 갖는 두 개의 변압기를 이용한 능동 클램프 포워드 컨버터 (A wide ZVS range two-transformer active-clamp forward converter with low conduction loss)

  • 문상철;박기범;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.369-371
    • /
    • 2006
  • Conventional active-clamp forward converter has narrow ZVS range of main switch. Although utilizing high magnetizing current can realize wide ZVS range, it increases the conduction loss. To solve this problem, a new asymmetric two-transformer active clamp forward converter is proposed. Proposed converter achieves wide ZVS range without severe conduction loss penalty, which results in high efficiency and high power density.

  • PDF

웨이브렛 변환을 바탕으로 한 신경회로망을 이용한 전력용 변압기 보호 계전기법 (The protective relaying scheme of power transformer using wavelet based neural networks)

  • 권기백;윤석무;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.229-232
    • /
    • 2001
  • This paper presents the protective relaying scheme as a method for discriminating of power transform's transient state associated with magnetizng inrush state, over-exciting state and internal fault using wavelet based neural networs. The simulation of EMTP with respect to different fault, inrush condition and over-exciting condition in transformer have been conducted, and the result prove that the proposed method is able to discriminate between inrush magnetizing current and internal fault.

  • PDF

클램핑 회로를 이용한 단계층 절연 역률 보정 전원 공급장치 (A Single Stage Isolated Power Factor Correction Power Supplies using Clamping Circuit)

  • 서재호;이희승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2021-2023
    • /
    • 1998
  • In this paper we further propose to add a very simple regenerative clamping circuit to SSIPP to reduce the voltage stress and to recycle the energy trapped in the leakage inductance of the isolation transformer, thus eliminating the need for a lossy snubber circuit. In addition, this proposed clamping circuit also provides a mechanism to reset the magnetizing current of the output transformer of SSIPP employing a Forward converter as the output stage. Simulations and experimental results are reported to verify the operation and performance of the SSIPP with regenerative clamping.

  • PDF

개선된 영전압 스위칭 액티브 포워드 컨버터 (An Improved ZVS Active Forward Conveter)

  • 최선호;박진영;김은수;강찬호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.59-63
    • /
    • 2004
  • In this paper, active forward converter with snubber circuit - composed of a tapped inductor, a snubber capacitor, two diodes - is proposed. By adding the snubber circuit, ZVS operation became possible even in a smaller magnetizing current conditions than the conventional converter. The operational principles and the equivalent mode analysis of the proposed converter is described and compared to conventional converter. We constructed the prototype active clamped forward converter with 300W output capacity and verified that efficiency of the proposed converter is higher than the conventional converter.

  • PDF

벡터제어 유도전동기의 모델추종 견실제어기 설계 (The Model-Following Robust Controller Design for the Vector-Controlled Induction Motor)

  • Chi Hwan Lee
    • 전자공학회논문지B
    • /
    • 제30B권11호
    • /
    • pp.93-101
    • /
    • 1993
  • The transfer function of vector-controlled induction motor is represented along with both unstructured and structured uncertainty such as the error of rotor time constant and current ripple. The low-pass-filter behavior of a magnetizing inductance gets rid of unstructured uncertainty in the transfer function. The robust controller to compensate variation of the transfer function is designed using simple P-I linear controllers. The coefficients of speed PI controller are determined from an overshoot and a rising time of system and the coefficients of model-following PI controller are obtained using the solution of Riccati equation of LQR control in the state space equation of the error system. Experimental results with the DSP-based model-following robust controller are shown a good robustness against the structured uncertainty of the motor.

  • PDF

Analysis and Implementation of a DC-DC Converter with an Active Snubber

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.779-786
    • /
    • 2011
  • This paper presents a soft switching converter to achieve the functions of zero voltage switching (ZVS) turn-on for the power switches and dc voltage step-up. Two circuit modules are connected in parallel in order to achieve load current sharing and to reduce the size of the transformer core. An active snubber is connected between two transformers in order to absorb the energy stored in the leakage and magnetizing inductances and to limit the voltage stresses across the switches. During the commutation stage of the two complementary switches, the output capacitance of the two switches and the leakage inductance of the transformers are resonant. Thus, the power switches can be turned on under ZVS. No output filter inductor is used in the proposed converter and the voltage stresses of the output diodes is clamped to the output voltage. The circuit configuration, the operation principles and the design considerations are presented. Finally, laboratory experiments with a 340W prototype, verifying the effectiveness of the proposed converter, are described.

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.

영구자석 선형동기전동기의 파라메터 산정 및 특성해석 (Parameter Estimation and Performance Analysis of Permanent Magnet Linear Synchronous Motor)

  • 임기채;우준근;홍정표;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.148-150
    • /
    • 1999
  • This paper deals with characteristic analysis of Permanent Magnet Linear Synchronous Motor(PMLSM). Parameters and characteristic variations are evaluated by using Finite Element Method (FEM) and Equivalent Magnetizing Current Method. PMLSM can be classified into the short primary type PMLSM and the short secondary type PMLSM according to their structural features. Especially, the short secondary type PMLSM is focused on because of good control characteristics. And this paper presents the difference of analysis results between the short primary type PMLSM and short secondary type PMLSM and investigates the end effect of two PMLSM's.

  • PDF