• Title/Summary/Keyword: Magnetized acupuncture needle

Search Result 3, Processing Time 0.018 seconds

Development of Magnetized Ferromagnetic Stainless Steel Acupuncture Needle (강자성(强磁性) 스테인리스강(鋼) 자화침(磁化鍼)의 개발)

  • Hong, Do Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.21-30
    • /
    • 2014
  • Objectives : Manufacturing and manipulation techniques of acupuncture can be interpreted as an induced electromagnetic viewpoint, as proposed in previous study. Considering from this point of view, the magnetization of needles should be essential to enhance the electromagnetic effects during the behavior of the acupuncture needling. Methods : The current disposable needles are made of non-magnetic stainless steels, so ferromagnetic materials were searched as suitable substitutes. Meanwhile, at the practical view, stainless steels are very available for the several superior properties like as corrosion resistance, strength, etc., magnetic stainless steels were first investigated. Some types of them still preserved the ferromagnetic properties of iron, so trial needles were made with them. And then magnetization of them were followed. Results : Among the hundreds types of stainless steels, martensitic or ferritic ones are ferromagnetic. The needles made with these ferromagnetic wires were magnetized, and polarized by magnetizer, and their magnetic properties were improved. Moreover, in addition to the superiority of the magnetism, the electrical and thermal conductivities of them were even better than those of the current austenitic stainless steels. Conclusions : Through the developmental study based on the electromagnetic viewpoint, the magnetized and polarized acupuncture needles were completed. This means that these needles having improved magnetism can be used to improve the electromagnetic needling effects, and moreover, their superiorities in the electrical and thermal conductivities can also give another benefits in treatments of electrical or warm needling.

A Study on the Characteristics of Manufacturing and the Electromagnetic Correlations of Traditional Acupuncture Needle (전통침의 제법(製法) 특성과 전자기적 상관성 연구)

  • Hong, Do Hyun
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.95-105
    • /
    • 2013
  • Objectives : The purpose of this study is to examine the preparing methods of the traditional acupuncture needle and to interpret the electromagnetic meaning intervened in them. Methods : The overall manufacturing processes of the acupuncture needles in ancient books were surveyed. And the facts that special functional activities were carried out in common in the preparing processes were detected. The reproduction tests for the detected former functional activities were followed. Results : According to the ancient medical books, the traditional acupuncture needles were treated with the magnet through the preparing processes. The reproduction tests provided the fact that the ferromagnetic iron needles treated with the magnet were enhanced their magnetisms. And major techniques of the ancient supplementation and draining can be interpreted as magnetic or induced electromagnetic actions. Conclusions : Considering the electromagnetic characteristics of human body, the magnet treated ferromagnetic iron needles of ancient era and magnetic or induced electromagnetic interpretable manipulation techniques are the historical evidences of magnetic activities of acupuncture. So modern acupuncture therapy should be understood, studied, and reinterpreted as an electromagnetic viewpoint.

Clinical Assessment of Warm Acupuncture Therapy System Using HF Time-varying Magnetic Field (고주파 자기장을 이용한 온침 치료시스템의 임상 평가)

  • Lee, Su-Yong;Byeon, Sang-Jun;Choi, Ye-Bin;Kim, Jin-Ju;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • Objectives : The aim of this paper is to develop acupuncture needle heating system by utilizing the new method which uses high frequency(HF) time-varying magnetic field. Also, it is possible to make an assessment for reliability and clinical significance of the system. Methods : We designed the system with solenoid coils for generation of HF time-varying magnetic field that oscillates at 150 kHz. Acupuncture needles are quickly magnetized and heated by 150 kHz. We assessed clinical significance of system, such as body temperature, pressure pulse waveform. Results : Temperature of acupuncture needle increased up to 60 degree. In the result for clinical significance of system, in case of manual acupuncture stimulation(MAS), body temperature change was $0.373^{\circ}C{\pm}0.224$(p<0.05), rate of pulse energy change increased about 7.6%. In case of warm acupuncture stimulation(WAS), body temperature change was $0.645^{\circ}C{\pm}0.281$(p<0.05), rate of pulse energy change remarkably increased about 35.9%. Conclusions : We confirm that the system is able to be applied clinically to various warm acupuncture needle therapy in the area of oriental medicine.