• Title/Summary/Keyword: Magnetization Loss

Search Result 159, Processing Time 0.026 seconds

A Study on AC Loss of Ag Sheathed Bi-2223 Superconducting Tapes (Bi계 초전도 테이프의 교류손실 연구)

  • Jeong, Jong-Man;Jang, Hyeon-Man;Sin, Jae-Hwa;Choe, Jae-Seok;Kim, Sang-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.29-33
    • /
    • 1999
  • Superconducting tape is being developed for electrical equipment such as superconducting transformers and generators etc. AC loss reduction is primary concerned in the development of such high-efficiency equipment. AC losses in Bi-2223 silver-sheathed tapes, both single and multi-filamentary, were investigated by means of AC magnetization techniques when longitudinal fields are applied. The experiment resultswere compared with the hysteresis loss equation based on Bean model and the eddy current loss equation. The AC loss of the mono-filamentary tape was dominated by the hysteresis. On the contrary, the AC loss of the multi-filamentary tape was substantially dominated by the eddy current loss in the silver matrix.

  • PDF

Test result of striated HTS compact cables for low AC loss

  • Kim, Y.;Kim, W.S.;Lee, J.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Large AC loss from the second generation (2G) high temperature superconducting (HTS) wires has been one of the major bottlenecks in power applications with HTS materials. Moreover, the large power applications also require the large current capacity from the HTS wires, which makes them produce larger AC losses. In order to reduce the AC loss from the HTS conductors with large current capacity, an HTS compact cable with some striations on the superconducting layers has been proposed. In this paper, we prepared some sample HTS compact conductors with striations, and measured their magnetization loss from the external magnetic field. We also made some slits on the superconducting layer of the HTS wire by laser cutting to reduce the aspect ratio of the superconducting layers. It would make the low eddy current loss and magnetic decoupling. Finally, the magnetization losses of the sample HTS compact conductors were measured and analyzed.

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

Rotor Loss Analysis of Permanent Magnet High-Speed Machine According to Magnetization Pattern

  • Cho, Han-Wook;Jang, Seok-Myeong;Lee, Sung-Ho;Yang, Hyun-Sup;Jeong, Yeon-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.103-107
    • /
    • 2004
  • Recently, greater attention has been paid to the high-speed generator for its many merits, such as ease of installation, high efficiency and high power density. However, due to their high fundamental frequency, careful consideration needs to be given to both electromagnetic and mechanical design issues. This paper deals with the comparison of two types of permanent magnet high-speed machines. Specifically, the effect of the permanent magnet magnetization pattern on the rotor losses is investigated. On the basis of analytical field analysis and the 2-D finite element method, this paper predicts the flux harmonics and rotor losses under the no-load condition. It is shown that the Halbach magnetization is superior to parallel magnetization in terms of producing rotor losses.

Influence of width and lateral separation of the strips on AC Loss in subdivided YBCO thin film (필라멘트 구조로 분리된 YBCO 박막에서 필라멘트 넓이와 간격이 교류손실에 미치는 영향)

  • Na D. H;Park H. W;Kim M. J;Chang Y. S;Kim J. M;Ri H. C;Lee Y. H
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.32-36
    • /
    • 2004
  • To investigate the influence of strip width and inter-strip separation on the ac loss, arrays of parallel strips with different widths and separations were prepared. Studies on the hysteresis-loss characteristics of multifilamentary YBCO films were performed. The local magnetic field due to magnetization currents is measured by a scanning Hall probe microscope. Based on these results a conceptual design for a low loss YBCO coated conductor is suggested.

  • PDF

AC Loss Characteristics of Technical High-$T_{c}$ Superconducting Tapes (실용 고온 초전도테이프의 교류손실 특성)

  • 김현준;허대행;조영호;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.11-14
    • /
    • 2003
  • The magnetization and self-field losses of the four technical high-T$_{c}$ superconducting tapes have been investigated experimentally. The results show that the magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.l.

  • PDF

The Influence of Magnetization Pattern on the Rotor Losses of Permanent Magnet High-Speed Machines (영구자석형 고속모터의 자화패턴에 따른 회전자 손실 해석)

  • Jang, Seok-Myeong;Cho, Han-Wook;Choi, Jang-Young;Yang, Hyun-Sup;Ryu, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.9-11
    • /
    • 2003
  • This paper deals with the comparison of rotor eddy current losses In two types of permanent magnet high-speed machines. The analytical method and two dimensional finite element analysis have been used to evaluate the rotor eddy current loss with the rotor magnetization Pattern. It is shown that the Halbach array produce rotor loss less than parallel magnetization.

  • PDF

The AC loss of 22.9kV/50MVA High-Tc Superconducting Power Cable (22.9kV/50MVA급 고온초전도 전력케이블의 교류손실)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook;Lee, Soo-Gil;Yang, Byeong-Mo;Yoon, Hyung-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.31-34
    • /
    • 2009
  • An HTS power cable is generally composed of 2 layers for conducting and 1 layer for shielding. For the analysis of AC loss of an HTS power cable, 2-dimensional magnetic field analysis is carried out. The magnetization loss in HTS cable core was calculated, and the transport current loss was obtained from the monoblock equation and the elliptical Norris Equation. And the total AC loss of the cable was expected by the sum of magnetization loss and transport current loss. The variation of ac loss with respect to the gap and uncertain factor between the superconducting tapes was investigated, and the ac loss of 22.9kV/50MVA high-Tc superconducting power cable was calculated. These results well agree with those of experiment.

Analysis of AC Losses in HIS Transformer with Double Pancake Windings (초전도 변압기 교류 손실 해석)

  • Kim Jong-Tae;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

Frequency dependence of AC loss in YBCO Bulk superconductor (YBCO Bulk 초전도체 교류손실의 주파수 의존성)

  • Ye, Jung-Hee;Nah, Wan-Soo;Kim, Chan-Jong;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.259-261
    • /
    • 1999
  • In this paper, we investigated the frequency dependences of AC loss and the magnetic properties of a superconductor using magnetization method. We used the YBCO bulk superconductor sample which has a square-shaped cross sectional area of $6mm{\times}6mm$. and 43mm-long in axial direction. The applied AC magnetic field was parallel to the direction of sample axis. It is observed that YBCO bulk has the diamagnetic properties. AC loss calculation of YBCO bulk superconductor was performed by evaluating the total area of magnetization traces. We performed two cases of experiments, one for $B_m<B_p$ and the other for $B_m<B_p$. The experiments showed that the AC loss dependences on frequency were different in each mode, as was indicated in other publications.

  • PDF