• Title/Summary/Keyword: Magnetic resonance perfusion

Search Result 147, Processing Time 0.023 seconds

A Case of Neuro-Behest's Disease: Comparison of Neurological Symptoms with PET, SPECT, and MRI Findings (신경 베체트병 1례: 신경학적 증상과 뇌 PET, SPECT, MRI 소견의 비교)

  • Kim, Jin-Wook;An, Min;Kim, So-Yon;Kim, Young-Jung;Cho, Min-Koo;Lee, Gwon-Jun;Lim, Sang-Moo;Hong, Sung-Woon;Choi, Chang-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.534-541
    • /
    • 1998
  • We describe a 27-year-old man who developed gait disturbance and dysarthria 2 years after the onset of cardinal symptoms of Behcet's disease. Positron emission tomography with $^{18}F$-fluorodeoxyglucose revealed severe hypometabolisrn in the cerebellum, in accordance with cerebellar symptoms and signs of the patient. However, single-photon emission tomography with $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD did not disclose significant perfusion abnormalities in the brain. Routine brain magnetic resonance imaging did not show signal abnormalities. The findings of imaging studies compared with neurological manifestations of the patient are discussed.

  • PDF

Occlusion of the Middle Cerebral Artery Branch Mimicking Aneurysm

  • Lee, Jung-Hwan;Ko, Jun-Kyeung;Lee, Sang-Weon;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.413-415
    • /
    • 2007
  • A 26-year-old man was admitted to our department due to intermittent left hemiparesis for 3 months. Magnetic resonance Image showed subacute infarction in the right precentral gyrus. Digital subtraction angiography and magnetic resonance angiography revealed an aneurysmal protrusion at the right middle cerebral artery (MCA) bifurcation. It was difficult to differentiate the aneurysm from the occlusion of the middle trunk of the MCA trifurcation. Brain single photon emission computerized tomography showed a decrease in perfusion in the right posterior frontal lobe without vascular reserve. Therefore, we planned a superficial temporal artery MCA anastomosis with an exploration of the right MCA bifurcation. Intraoperatively, the aneurysmal opacification on preoperative angiography proved to be the proximal stump of the occluded middle trunk of the MCA trifurcation. An aneurysmal protrusion at the MCA bifurcation does not always indicate an aneurysm. In diagnosing protruding vascular lesions at the MCA bifurcation, the possibility of a vascular stump should be considered according to their angioanatomical appearance and the history of the patient.

Alzheimer Dementia and Microvascular Pathology: Blood-Brain Barrier Permeability Imaging (알츠하이머 치매와 미세뇌혈관병리: 혈액뇌장벽 투과도 영상)

  • Won-Jin Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.488-500
    • /
    • 2020
  • Accumulating evidence suggests that Alzheimer's disease (AD) is not only caused by accumulation of abnormal proteins, including amyloid and tau, but is also closely associated with abnormalities in the microvascular environment including the blood-brain barrier (BBB), both of which lead to neuroinflammation and neurodegeneration. Application of in vivo magnetic resonance imaging (MRI) has recently increased to assess BBB permeability in AD and related diseases. Here, we provide a narrative review of BBB permeability-related pathology in Alzheimer dementia and recent MRI research on BBB permeability changes in AD and related diseases. Furthermore, we briefly introduce the measurement of BBB permeability using MRI and its methodological issues.

Assessment of Non-permeability of Gd-DTPA for Dynamic Susceptibility Contrast in Human Brain: A Preliminary Study Using Non-linear Curve Fitting (뇌영역의 동적 자화율 대조도 영상에서 Gd-DTPA 조영제의 비투과성 조사: 새로운 비선형 곡선조화 알고리즘 개발의 예비연구)

  • Yoon, Seong-Ik;Jahng, Geon-Ho;Khang, Hyun-Soo;Kim, Young-Joo;Choel, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 2007
  • To develop an advanced non-linear curve fitting (NLCF) algorithm for performing dynamic susceptibility contrast study of the brain. The first pass effects give rise to spuriously high estimates of $K^{trans}$ for the voxels that represent the large vascular components. An explicit threshold value was used to reject voxels. The blood perfusion and volume estimation were accurately evaluated in the $T2^*$-weighted dynamic contrast enhanced (DCE)-MR images. From each of the recalculated parameters, a perfusion weighted image was outlined by using the modified non-linear curve fitting algorithm. The present study demonstrated an improvement of an estimation of the kinetic parameters from the DCE $T2^*$-weighted magnetic resonance imaging data with using contrast agents.

  • PDF

The effects of labeling gap and susceptibility artifacts in pCASL perfusion MRI (pCASL 관류 영상에서 표지 간격과 자화감수성 인공물이 영상에 미치는 영향)

  • Kim, Seong-Hu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.213-217
    • /
    • 2015
  • To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin Labeling) was acquired together with the structural image simply by changing position(labeling gap 15 mm, 170 mm) of the labeling pulse to avoid stent. Data was processed through the ASLtbx. When perfusion MRI was acquired using pCASL, it showed that the position of the conventional labeling pulse (labeling gap 24 mm) was overlapped with that of stent, which made signal intensity in right brain tissue appear as if it were void. When the labeling pulse was positioned (labeling gap 15 mm) to avoid stent, high signal intensity images were acquired. In labeling pulse (labeling gap 170 mm), the signal intensity was more reduced due to relaxation before labeled blood arrived at the imaging slice. pCASL can be stably repeated measurements because it does not use a contrast agent. And it should be selected with the appropriate image acquisition parameters for the high quality image.

Perfusion MR Imaging of Cerebral Gliomas: Comparison with Histologic Tumor Grade (대뇌 교종의 관류 자기 공명 영상: 조직학적 종양등급과의 비교)

  • 최충곤;정애경;김정훈;강신광;이호규
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.130-137
    • /
    • 2001
  • Purpose : Our purpose was to compare maximum relative cerebral blood volume (rCBV) with histologic grade of cerebral gliomas. Materials and methods : First-pass perfusion MR imaging was performed preoperatively in 16 patients with pathologically proven cerebral gliomas (7 glioblastoma, 2 anaplastic astrocytoma, 1 anaplastic oligodendroglioma, 5 low-grade astrocytoma, and 1 low-grade oligodendroglioma). Maximum rCBV was compared with histologic diagnosis and grade of the tumor. Results : Maximum rCBVs of glioblastomas were in the range of 433% to-1330% (average, 790 %), as compared with those of contra-lateral normal white matters. Maximum rCBVs of two non-enhancing anaplastic astrocytomas were 66% and 284%, respectively. Maximum rCBV of one well-enhancing anaplastic oligodendroglioma was 702%. Maximum rCBVs of low-grade astrocytomas were in the range of 80%-369% (average, 202%). Maximum rCBV of one low-grade oligodendroglioma was 1450%, even higher than those of glioblastomas. Conclusion : Maximum rCBV was higher in glioblastoma than in low-grade astrocytoma without overlapping. However, there was no difference of maximum rCBV between non-enhancing anaplastic astrocytoma and low-grade astrocrtoma.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI (고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교)

  • Goo, Eun-Hoe;Chae, Hong-In;Park, Jong-Bae;Im, Cheong-Hwan;Kim, Jeong-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF