• 제목/요약/키워드: Magnetic resonance images

검색결과 1,125건 처리시간 0.027초

Pediatric Magnetic Resonance Enterography: Focused on Crohn's Disease

  • Lee, So Mi;Kim, Woo Sun;Choi, Young Hun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권3호
    • /
    • pp.149-159
    • /
    • 2015
  • Crohn's disease is a chronic idiopathic inflammatory disease of the intestines characterized by frequent relapse and remission. It often develops in children and adolescents, who are vulnerable to repeated exposure to ionizing radiations. Magnetic resonance enterography (MRE) is an increasingly important radiation-free imaging modality that is used to evaluate pediatric patients with Crohn's disease. MRE can evaluate extraluminal and extraintestinal abnormalities as well as the status of the bowel wall. In addition, MRE has an advantage in the evaluation of the small bowel involvement. MRE can be used for the initial diagnosis of Crohn's disease, and can aid in the assessment of disease activity and complications such as penetrating and fibrostenotic diseases. The aims of this article are to review the MRE technique for obtaining diagnostic and high-quality images and to discuss interpretations of imaging findings in patients with Crohn's disease.

Extranodal Malignant Lymphoma Concurrent Involving Female Urethra and Cervix: a Case Report

  • Kim, Dong Chan;Kim, You Me
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.168-173
    • /
    • 2020
  • Extranodal lymphoma presents in almost one-third of all non-Hodgkin lymphoma cases. The gastrointestinal tract, skin, and central nervous system are common sites of involvement, whereas the urethra and cervix are very rare. To the best of our knowledge, this is the first report on concurrent extranodal involvement of the uterine cervix and urethra. We report imaging findings of malignant lymphoma involving urethra and cervix concurrently in a 79-year-old female patient with literature review. The magnetic resonance imaging showed huge intermediate to high signal intensity mass on T2 weighted images and strong homogeneous enhancement in uterine cervix and periurethral area, but no surrounding architectural disruption.

A Case of Metronidazole-Induced Encephalopathy: Atypical Involvement of the Brain on MRI

  • Hwang, Eunjin;Chang, Suk-Ki;Lee, Seun-Ah;Choi, Jung-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.200-203
    • /
    • 2018
  • Metronidazole is an antimicrobial agent widely used for the treatment of anaerobic infection or antibiotics-associated diarrhea. It is generally thought to be safe, but can induce reversible toxic encephalopathy in the case of excessive or cumulative over-dose. Metronidazole-induced encephalopathy generally demonstrates the characteristic features of typical lesion location and bilaterality on magnetic resonance imaging (MRI). We report a case of metronidazole-induced encephalopathy with the involvement of asymmetric white matter. To our knowledge, only a few cases have been reported with respect to white matter lesion characteristics on MRI with diffusion-weighted images.

The MRI Findings of Flexor Digitorum Accessorius Longus Muscle: a Case Report

  • Shin, Jae Hwan;Shim, Jae-Chan;Lee, Kyoung Eun;Kim, Ho Kyun;Lee, Ghi Jai;Suh, Jung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.123-126
    • /
    • 2016
  • The flexor digitorum accessorius longus (FDAL) is the most common accessory muscle found in the posterior compartment of the ankle area. The accessory muscle in this area such as the FDAL may be incidentally identified on magnetic resonance images (MRI). There are some case reports about the FDAL in cadaver researches. However, the MRI findings about the FDAL have been reported in a few cases. In this paper, we report a case of the FDAL incidentally identified on MRI with review of the literature about the FDAL.

MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY

  • Kwon, Oh-In;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • 대한수학회논문집
    • /
    • 제16권3호
    • /
    • pp.519-541
    • /
    • 2001
  • Magnetic Resonance Electrical Impedance Tomography(MREIT) is a new medical imaging technique for the cross-sectional conductivity distribution of a human body using both EIT(Electrical Impedance Tomography) and MRI(Magnetic Resonance Imaging) system. MREIT system was designed to enhance EIT imaging system which has inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. MREIT utilizes a recent CDI (Current Density Imaging) technique of measuring the internal current density by means of MRI technique. In this paper, a mathematical modeling for MREIT and image reconstruction method called the alternating J-substitution algorithm are presented. Computer simulations show that the alternating J-substitution algorithm provides accurate high-resolution conductivity images.

  • PDF

Pancreatic Paraganglioma: a Case Report and Literature Review

  • Park, Joon Suk;Min, Seon Jeong;Min, Soo Kee;Choi, Jung-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.47-52
    • /
    • 2021
  • Paraganglioma is a rare tumor of paraganglia, derived from neural crest cells in sympathetic or parasympathetic ganglions. It can be widely distributed from the skull base to the bottom of the pelvis. The pancreas, however, is a rare location of this neoplasm, and only a limited number of cases have been reported in the English literature, especially with gadoxetic-acid-enhanced magnetic resonance imaging (MRI) and diffusion-weighted images (DWI). We herein report a case of pathologically proven paraganglioma in the pancreas head with a literature review on endoscopic ultrasonography (EUS), computed tomography (CT), gadoxetic-acid-enhanced MRI, and DWI sequence.

Unilateral Chronic Organizing Hematoma after Breast Explantation Mimicking Chest Wall Tumor: a Case Report with Imaging Features

  • Jang, Seon Woong;Lee, Ji Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.76-81
    • /
    • 2022
  • The number of women undergoing breast augmentation surgery with a prosthesis for cosmetic purposes or reconstruction after a mastectomy is steadily increasing. Hematoma is one of complications associated with breast augmentation surgery. It usually occurs early in the postoperative period. It rarely occurs late (after six months). However, chronic hematomas after prosthesis removal have not yet been reported in the radiological literature. We present a case of unilateral chronic organizing hematoma that developed late and grew persistently over long period after breast explantation, mimicking a soft tissue tumor of the chest wall clinically. Meanwhile, characteristic magnetic resonance imaging features of heterogeneous signal intensities on T1-weighted and T2-weighted images and dark signal intensity with a persistent enhancement of the peripheral wall of the lesion were found. These can be used for a differential diagnosis.

자화율 차이로 인해 왜곡된 영상으로부터 금속 바늘의 위치 결정 (Determining the Location of Metallic Needle from MR Images Distorted by Susceptibility Difference)

  • 김은주;김대홍
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.87-94
    • /
    • 2010
  • 목적: 금속에 의한 영상 왜곡에 대한 정확한 계산하고 영상으로부터의 금속 물질의 위치 결정한다. 대상 및 방법: 주자기장과 일정 각도를 이루는 무한히 긴 비자성 금속 실린더에 대한 라플라스 방정식을 풀고, 이 결과를 이용하여 절편선택 경사자계와 주파수 부호화 경사자계에 의한 영상에 왜곡을 계산한다. 계산 결과를 바탕으로 하여 왜곡된 영상으로부터 원통형 보철물의 위치를 계산한다. 결과: Folded point와 금속 실린더의 중심 사이의 거리를 영상으로부터 측정하여 계산 결과와 비교한다. 측정 결과와 계산 결과 간의 퍼센트 오차는 한 경우를 제외하고 5% 이내였다. 결론: 금속 실린더가 자기장 하에 있을 때, 영상의 왜곡을 시뮬레이션 하였고, 이 기술은 생검술 또는 외과 수술 등을 자기공명영상법을 이용여 실시간 모니터링하는데 적용할 수 있을 것으로 기대한다.

자장 세기와 스캔 방향이 다른 자기공명영상에서 측정된 해마 체적의 재현성 연구 (A study on the reproducibility of hippocampal volumes measured using magnetic resonance images of different magnetic field strengths and slice orientations)

  • 최유용;이동희;이상웅;이건호;권구락
    • 스마트미디어저널
    • /
    • 제5권1호
    • /
    • pp.44-48
    • /
    • 2016
  • 장기추적 뇌영상 연구에서 자기공명영상장치의 노후 또는 기술 발전에 따른 업그레이드로 인해 연구기간 내 동일한 촬영 조건을 유지하기 어렵다. 특히, 자장 세기가 1.5T에서 3T로 증가한 경우가 많아, 기존 1.5T 영상을 새로운 3T 영상과 통합해서 분석에 사용하는 것이 가능한지 확인할 필요가 있다. 본 논문에서는 자장 세기와 스캔 방향이 다른 자기공명영상에서 측정한 해마 체적의 재현성을 연구 분석하였다. 실험참가자 296명의 3차원 T1 영상을 1.5와 3T 자기공명영상장치 각각에서 스캔 방향을 달리하여 획득하고 뇌영상 연구에 널리 사용되는 Freesurfer를 이용하여 실험참가자의 해마 체적을 측정하였다. 해마 체적의 영상종류 간 차이를 확인하기 위해 대응표본t-검정을 수행한 결과, 자기공명영상장치의 자장 세기와 스캔 방향에 따라 해마체적이 유의하게 차이가 있음을 확인하였다. 이런 결과는 촬영조건에 따라 측정된 해마체적이 달라질 수 있음을 의미하므로, 촬영 조건이 다른 영상을 통합 분석할 수 있는 기법의 개발이 필요하다고 판단된다.

적응 템플릿 필터링에서의 Edge artifact 제거 (Reduction of Edge Artifact in Adaptive Template Filtering)

  • 안창범;송영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2921-2923
    • /
    • 2000
  • Adaptive template filtering has been proposed recently for an enhancement of signal-to-noise ratio. In some magnetic resonance images whose gray levels have relatively small dynamic ranges, e.g., T1 imaging, however, artificial stair-like artifact is observed in edge regions. This is partially due to edge enhancement effect in such voxels that contain multiple compounds at the boundaries of tissues. The gray levels of these voxels tend to change those of near voxels that contain single compound by the adaptive filtering, which exaggerate edge discontinuities. In this paper, we propose a technique to eliminate such artifact by identifying those voxels and assigning a larger template for them. Filtered images with the proposed technique show substantial visual enhancement at the edges without degradation of peak signal-to-noise ratio compared to the original adaptive template filtering for both magnetic resonance images and phantom images

  • PDF