• Title/Summary/Keyword: Magnetic resonance

Search Result 6,490, Processing Time 0.029 seconds

Functional and Structural Characterization of Drosocin and its Derivatives Linked O-GalNAc at Thr11 Residue

  • Ahn, Mi-Ja;Sohn, Ho-Ik;Nan, Yong Hai;Murugan, Ravichandran N.;Cheong, Chae-Joon;Ryu, Eun-Kyoung;Kim, Eun-Hee;Kang, Shin-Won;Kim, Eun-Joo;Shin, Song-Yub;Bang, Jeong-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3327-3332
    • /
    • 2011
  • Antimicrobial peptides have recently gained the much attention because of their ability to make defense system from attacking bacterial infections. Drosocin has been considered as very attractive antibiotic agents because of low toxicity against human erythrocytes and active at the low concentration. We have studied the structureactivity relationship of a glycopeptide drosocin focused on the N-acetyl-D-galactoside at $Thr^{11}$ residue. Based on the radial diffusion assay, we found that the acetylation of carbohydrate moiety increased the antimicrobial activity and the $Pro^{10}$, present in the middle of drosocin plays an important role in the antimicrobial activity. Our results provide a good lead compound for further studies on the design of drosocin-based analogues targeting glyco linked Thr site.

PERFORATION OF THE TEMPOROMANDIBULAR JOINT MENISCUS: DIAGNOSED BY MAGNETIC RESONANCE IMAGING (MAGNETIC RESONANCE IMAGING을 이용한 악관절 원판 천공 진단)

  • Kim, Houng-Gon;Dolan, Eward;Vogler, James B.;Nokes, Steven R.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.2
    • /
    • pp.11-18
    • /
    • 1989
  • Advancement of surgical techniques has made it necessary to accurately diagnose internal derangements. Arthrography and computerized tomography have been used to diagnose the majority of temporomandibular joint disorders, however, these methods have had their disadvantages. Magnetic resonance imaging utilizing surface coils has greatly improved the ability to diagnose meniscus abnormalities without using intrarticular injections or ionizing radiation. Ninety-two patients (184 joints) were evaluated by means of magnetic resonance imaging(MRI). Thirty-one patients (39 joints) were diagnosed as having meniscus perforation. Retrospective review of fifteen patients (20 joints) with a perforated meniscus diagnosed by magnetic resonance imaging pre-operatively demonstrated a sixty-five percent correlation between the radiographic diagnosis and the surgical findings.

  • PDF

Folate Receptor-Specific Positron Emission Tomography Imaging with Folic Acid-Conjugated Tissue Inhibitor of Metalloproteinase-2

  • Kim, Sung-Min;Choi, Naeun;Hwang, Seungkyun;Yim, Min Su;Lee, Jung-Sik;Lee, Sang-Mok;Cho, Gyunggoo;Ryu, Eun Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3243-3248
    • /
    • 2013
  • The tissue inhibitor of metalloproteinase-2 (TIMP-2) inhibits matrix metalloproteinases activity and modulates cellular proliferation and apoptosis. The human serum albumin-TIMP-2 with folic acid conjugate (termed HT2-folate) was synthesized to promote uptake through folate receptors (FRs), and a corresponding radio-labeled compound was prepared for tumor diagnosis by positron emission tomography (PET). $^{68}Ga$-NOTA-HT2-folate was synthesized from $^{68}Ga$ and the NOTA chelator with HT2-folate. The fusion protein was identified using MALDI-TOF mass spectrometry. The radioligand was prepared with a high radiochemical yield. Cell-surface association of $^{68}Ga$-NOTA-HT2-folate significantly increased over time in FR-positive tumor cells. In animal PET and biodistribution studies, tumor uptake was very high as early as 1 h after radioligand injection. Folate conjugation enhanced the selective receptor-targeting efficacy of HT2 in FRexpressing tumors, and its radioligand will be useful as an in vitro tool and for in vivo tumor diagnosis by PET imaging.

Quality Characteristics of Korean Rice Cake by Freezing Methods (냉동 방법에 따른 떡의 품질특성 변화)

  • Lee, Hye-Jin;Ku, Su-Kyung;Choi, Hee-Don;Park, Jong-Dae;Sung, Jung-Min;Kim, Young-Boong;Choi, Hyun-Wook;Choi, Yun-Sang
    • Korean journal of food and cookery science
    • /
    • v.33 no.2
    • /
    • pp.148-154
    • /
    • 2017
  • Purpose: Frozen Korean traditional rice cakes (Sulgitteok and Garaetteok) were evaluated different conditions ($-20^{\circ}C$ and $-10^{\circ}C$) freezing (magnetic resonance quick freezing and air blast freezing) to study differences in quality characteristics. Methods: Experiments analyze Korean rice cakes for water content, water activity, color, textural properties, and sensory characteristics. Results: Moisture content showed high value at $-20^{\circ}C$ freezing regardless of freezing method. Water activity was higher at $-20^{\circ}C$ than $-10^{\circ}C$, and water activity higher magnetic resonance quick freezing than air blast freezing. The lightness values were higher $-20^{\circ}C$ freezing temperature compare to $-10^{\circ}C$ freezing temperature. Hardness and chewiness were the lowest $-20^{\circ}C$ magnetic resonance quick freezing. sensory evaluation both Sulgitteok and Garaetteok showed better overall acceptability at $-20^{\circ}C$ magnetic resonance quick freezing. Conclusion: Therefore, the $-20^{\circ}C$ magnetic resonance quick freezing method resulted in favorable textural properties and sensory characteristics.

Direct characterization of E2-dependent target specificity and processivity using an artificial p27-linker-E2 ubiquitination system

  • Ryu, Kyoung-Seok;Choi, Yun-Seok;Ko, Jun-Sang;Kim, Seong-Ock;Kim, Hyun-Jung;Cheong, Hae-Kap;Jeon, Young-Ho;Choi, Byong-Seok;Cheong, Chae-Joon
    • BMB Reports
    • /
    • v.41 no.12
    • /
    • pp.852-857
    • /
    • 2008
  • Little attention has been paid to the specificity between E2 and the target protein during ubiquitination, although RING-E3 induces a potential intra-molecular reaction by mediating the direct transfer of ubiquitin from E2 to the target protein. We have constructed artificial E2 fusion proteins in which a target protein (p27) is tethered to one of six E2s via a flexible linker. Interestingly, only three E2s (UbcH5b, hHR6b, and Cdc34) are able to ubiquitinate p27 via an intra-molecular reaction in this system. Although the first ubiquitination of p27 (p27-Ub) by Cdc34 is less efficient than that of UbcH5b and hHR6b, the additional ubiquitin attachment to p27-Ub by Cdc34 is highly efficient. The E2 core of Cdc34 provides specificity to p27, and the residues 184-196 are required for possessive ubiquitination by Cdc34. We demonstrate direct E2 specificity for p27 and also show that differential ubiquitin linkages can be dependent on E2 alone.

Molecular Imaging of Arthritis in the Angiogenic Vasculature Using A 123I-Vascular Endothelial Growth Factor Receptor Antibody

  • Kim, Sung-Min;Choi, Na-Eun;Song, Young-Kyu;Cho, Gyung-Goo;Bang, Jeong-Kyu;Kim, Sang-Mi;Lee, Sang-Hoon;Ryu, Eun-Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1890-1894
    • /
    • 2012
  • Vascular endothelial growth factor (VEGF) and its receptor (VEGFR) have been implicated in the pathogenesis of rheumatoid arthritis, which is angiogenesis dependent. Antibody-based molecular imaging improves targeting, and antibody radiolabeling is useful for monitoring biological events $in$ $vivo$ $via$ PET or SPECT. We investigated the potential of molecular imaging to diagnose arthritis with VEGFR-2 $in$ $vivo$. The $^{123}I$-VEGFR-2 antibody was prepared by the iodogen tube method. The radioligand was injected into arthritic mice, and micro SPECT/CT was performed. The arthritic mice were examined by 4.7-T MRI and immunohistochemistry. The $^{123}I$-VEGFR-2 antibody showed high uptake in the arthritic region at 1 h postinjection on SPECT/CT but no uptake in the control animals after radioligand injection. In MR images, the arthritic tissue of the mice was correlated with regions labeled by the $^{123}I$-VEGFR-2 antibody. Immunohistochemical localization showed markedly increased expression of VEGFR-2 in the endothelial cells, fibroblasts, and macrophages of the arthritic mice.

Cerebrospinal fluid flow in normal beagle dogs analyzed using magnetic resonance imaging

  • Cho, Hyunju;Kim, Yejin;Hong, Saebyel;Choi, Hojung
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.2.1-2.10
    • /
    • 2021
  • Background: Diseases related to cerebrospinal fluid flow, such as hydrocephalus, syringomyelia, and Chiari malformation, are often found in small dogs. Although studies in human medicine have revealed a correlation with cerebrospinal fluid flow in these diseases by magnetic resonance imaging, there is little information and no standard data for normal dogs. Objectives: The purpose of this study was to obtain cerebrospinal fluid flow velocity data from the cerebral aqueduct and subarachnoid space at the foramen magnum in healthy beagle dogs. Methods: Six healthy beagle dogs were used in this experimental study. The dogs underwent phase-contrast and time-spatial labeling inversion pulse magnetic resonance imaging. Flow rate variations in the cerebrospinal fluid were observed using sagittal time-spatial labeling inversion pulse images. The pattern and velocity of cerebrospinal fluid flow were assessed using phase-contrast magnetic resonance imaging within the subarachnoid space at the foramen magnum level and the cerebral aqueduct. Results: In the ventral aspect of the subarachnoid space and cerebral aqueduct, the cerebrospinal fluid was characterized by a bidirectional flow throughout the cardiac cycle. The mean ± SD peak velocities through the ventral and dorsal aspects of the subarachnoid space and the cerebral aqueduct were 1.39 ± 0.13, 0.32 ± 0.12, and 0.76 ± 0.43 cm/s, respectively. Conclusions: Noninvasive visualization of cerebrospinal fluid flow movement with magnetic resonance imaging was feasible, and a reference dataset of cerebrospinal fluid flow peak velocities was obtained through the cervical subarachnoid space and cerebral aqueduct in healthy dogs.

Computed tomography and magnetic resonance imaging characteristics of giant cell tumors in the temporomandibular joint complex

  • Choi, Yoon Joo;Lee, Chena;Jeon, Kug Jin;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.149-154
    • /
    • 2021
  • Purpose: This study aimed to investigate the computed tomography and magnetic resonance imaging features of giant cell tumors in the temporomandibular joint region to facilitate accurate diagnoses. Materials and Methods: From October 2007 to June 2020, 6 patients (2 men and 4 women) at Yonsei University Dental Hospital had histopathologically proven giant cell tumors in the temporomandibular joint. Their computed tomography and magnetic resonance imaging findings were reviewed retrospectively, and the cases were classified into 3 types based on the tumor center and growth pattern observed on the radiologic findings. Results: The age of the 6 patients ranged from 25 to 53 years. Trismus was found in 5 of the 6 cases. One case recurred. The mean size of the tumors, defined based on their greatest diameter, was 32 mm (range, 15-41 mm). The characteristic features of all cases were a heterogeneously-enhancing tumorous mass with a lobulated margin on computed tomographic images and internal multiplicity of signal intensity on T2-weighted magnetic resonance images. According to the site of origin, 3 tumors were bone-centered, 2 were soft tissue-centered, and 1 was peri-articular. Conclusion: Computed tomography and magnetic resonance imaging yielded a tripartite classification of giant cell tumors of the temporomandibular joint according to their location on imaging. This study could help clinicians in the differential diagnosis of giant cell tumors and assist in proper treatment planning for tumorous diseases of the temporomandibular joint.

Can indirect magnetic resonance arthrography be a good alternative to magnetic resonance imaging in diagnosing glenoid labrum lesions?: a prospective study

  • Mardani-Kivi, Mohsen;Alizadeh, Ahmad;Asadi, Kamran;Izadi, Amin;Leili, Ehsan Kazemnejad;arzpeyma, Sima Fallah
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.182-187
    • /
    • 2022
  • Background: This study was designed to evaluate and compare the diagnostic value of magnetic resonance imaging (MRI) and indirect magnetic resonance arthrography (I-MRA) imaging with those of arthroscopy and each other. Methods: This descriptive-analytical study was conducted in 2020. All patients who tested positive for labrum lesions during that year were included in the study. The patients underwent conservative treatment for 6 weeks. In the event of no response to conservative treatment, MRI and I-MRA imaging were conducted, and the patients underwent arthroscopy to determine their ultimate diagnosis and treatment plan. Imaging results were assessed at a 1-week interval by an experienced musculoskeletal radiologist. Image interpretation results and arthroscopy were recorded in the data collection form. Results: Overall, 35 patients comprised the study. Based on the kappa coefficient, the results indicate that the results of both imaging methods are in agreement with the arthroscopic findings, but the I-MRA consensus rate is higher than that of MRI (0.612±0.157 and 0.749±0.101 vs. 0.449±0.160 and 0.603±0.113). The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of MRI in detecting labrum tears were 77.77%, 75.00%, 91.30%, 50.00%, and 77.14%, respectively, and those of I-MRA were 88.88%, 75.00%, 92.30%, 66.66%, and 85.71%. Conclusions: Here, I-MRA showed higher diagnostic value than MRI for labral tears. Therefore, it is recommended that I-MRA be used instead of MRI if there is an indication for potential labrum lesions.

The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

  • Jongmin J. Lee;Phillip J. Tirman;Yongmin Chang;Hun-Kyu Ryeom;Sang-Kwon Lee;Yong-Sun Kim;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.142-151
    • /
    • 2000
  • Objective: To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods: Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results: Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion: The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method.

  • PDF