• 제목/요약/키워드: Magnetic moment

검색결과 325건 처리시간 0.029초

Magnetic Properties of Carbon Chains Doped with 4d Transition Metals

  • Jang, Y.R.;Lee, J.I.
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.7-10
    • /
    • 2008
  • The structural and magnetic properties of functionalized carbon chains doped with 4d transition metals, such as Ru, Rh, and Pd, were investigated using the full-potential linearized augmented plane wave (FLAPW) method. The carbon nanowire doped with Ru exhibited a ferromagnetic ground state with a sizable magnetic moment, while those doped with Rh and Pd had nonmagnetic ground states. For the Ru-doped chain, the density of states at the Fermi level showed large spin polarization, which suggests that the doped nanowire could be used for spintronic applications.

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • 제13권3호
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

동작 전류에 의한 Magnetic fluid Linear Pump의 동특성 해석 (Analysis of the Driving Characteristics in the Magnetic Fluid Linear Pump by Operating Current)

  • 서강;박관수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.237-246
    • /
    • 2004
  • The advantages of the Magnetic Fluid Linear Pump(MFLP) is that this device could Pump the non-conductive. non-magnetic liquid such as Insulin or blood because of the segregation structure of the magnetic fluid and pumping liquid. In this device. the sequential currents are needed to Produce pumping forces so that Pumping Forces and Pumping speed mainly depend on the current Patterns. The excessive forces at Pumping moment could cause the medical shock, and weak forces at intermediate moment could cause the back flow or the pumping liquid. So the ripples of the pumping forces need to be reduced for the medical application. In this research, the driving characteristics in the MFLP by operating current is analysed. The change of magnetic fluid surface according to the driving currents could be obtained be magneto-hydrodynamic analysis so that Pumping fortes could be computed by integration of the surface moving to the pumping direction at each moment. The actual MFLP with 13mm diameter was made and tested for experiments. The effects of driving current and frequency on the pumping forces and pumping speed were analyzed and compared with experimental measurements.

Ni 단층이 삽입된 Rh 박막의 전자구조와 자성 (Electronic Structure and Magnetism of Ni Monolyer Embedded Between Rh Layers)

  • 김선희;장영록;이재일
    • 한국자기학회지
    • /
    • 제15권1호
    • /
    • pp.7-11
    • /
    • 2005
  • 비자성 전이금속인 Rh 여러 층 사이에 자성 전이금속인 Ni 한층을 넣은 4Rh/Ni/4Rh(001) 계에서 Rh과 Ni의 자기 모멘트 진동현상을 FLAPW(full-potential linearized augmented plane wave) 방법을 이용하여 연구하였다. 가운데 층에 있는 Ni의 자기 모멘트를 계산한 결과는 0.34${\mu}_B$으로 덩치 Ni의 값보다 약 40% 감소한 값이다. Ni과의 강한 띠 혼성으로 Rh의 각 원자 층에 자기모멘트의 변화가 나타났는데 이 변화는 중심에서 표면으로 갈수록 작아지는 감쇠 진동을 하였다. Rh의 영향을 받아 가운데 Ni층의 폐르미 준위가 Ni의 에너지 띠 안쪽으로 이동하여 Ni의 전자수가 줄어들고 있음을 계산된 상태밀도 모양에서 알 수 있었다.

가전기기 발생 극저주파 자계 고조파 특성 해석 (Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances)

  • 민석원;송기현;양광호;주문노
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

Fluorine-Induced Local Magnetic Moment in Graphene: A hybrid DFT study

  • 김현중;조준형
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.127.1-127.1
    • /
    • 2013
  • Recent experimental evidence that fluorinated graphene creates local magnetic moments around F adatoms has not been supported by semilocal density-functional theory (DFT) calculations where the adsorption of an F adatom induces no magnetic moment in graphene. Here, we show that such an incorrect prediction of the nonmagnetic ground state is due to the self-interaction error inherent in semilocal exchange-correlation functionals. The present hybrid DFT calculation for an F adatom on graphene predicts not only a spin-polarized ground state with a spin moment of ${\sim}1{\mu}_B$, but also a long-range spin polarization caused by the bipartite nature of the graphene lattice as well as the induced spin polarization of the graphene states. The results provide support for the experimental observations of local magnetic moments in fluorinated graphene.

  • PDF

AlN 반도체와 Cu의 도핑 농도에 대한 자성 (Magnetic Properties of Cu-doped AlN Semiconductor)

  • 강병섭;이행기
    • 반도체디스플레이기술학회지
    • /
    • 제9권3호
    • /
    • pp.1-4
    • /
    • 2010
  • First-principles calculations based on spin density functional theory are performed to study the spin-resolved electronic properties of AlN doped with a Cu concentration of 6.25%-18.75%. The ferromagnetic state is more energetically favorable state than the antiferromagnetic state or the nonmagnetic state. For $Al_{0.9375}Cu_{0.0625}N$, a global magnetic moment of 1.26 mB per supercell, with a localized magnetic moment of 0.75 $m_B$ per Cu atom is found. The magnetic moment is reduced due to an increase in the number of Cu atoms occupying adjacent cation lattice position. For $Al_{0.8125}Cu_{0.1875}N$, the magnetism of the supercell disappears by the interaction of the neighboring Cu atoms. The nonmagnetic to ferromagnetic phase transition is found to occur at this Cu concentration. The range of concentrations that are spin-polarized should be restricted within very narrow.

X-선 자기 원형 이색성 (X-Ray Magnetic Circular Dichroism)

  • 김재영
    • 한국자기학회지
    • /
    • 제20권5호
    • /
    • pp.201-205
    • /
    • 2010
  • X-선 자기 원형 이색성 측정은 자성물질을 구성하는 원소별 자기적 성질의 측정 및 궤도 자기 모멘트와 스핀 자기 모멘트를 구별하여 측정할 수 있다는 장점으로 인해 여러 가지 자성 신물질 및 다양한 기능성 자성 다층 박막의 연구에 많이 이용되어 왔다. 이 글에서는 이러한 X-선 자기 원형 이색성 현상의 원리 및 실험 방법 등을 설명하겠다. 또한 몇 가지 X-선 자기 원형 이색성을 이용한 최근 몇 가지 연구도 소개하려 한다.

주기적 결함을 가진 철 단층의 전자구조와 자성 (Electronic Structure and Magnetism of Fe Monolayer with Periodic Defects)

  • ;;이재일
    • 한국자기학회지
    • /
    • 제19권5호
    • /
    • pp.161-164
    • /
    • 2009
  • 주기적 결함이 철 단층의 자성에 미치는 영향을 탐구하기 위해 전전자 총퍼텐셜 보강평면파 에너지 띠 방법을 이용하여 전자구조를 계산하였다. 결함은 원자 한 개가 빈 점결함, 각기 3개, 5개, 7개의 원자자리가 비어 있는 I 자형, + 모양, H 자 모양을 고려하였다. 빈자리에 가까이 있는 철 원자의 자기모멘트가 가장 컸으며, 결함의 원자수가 증가할수록 그 값도 증가하여, 점결함의 경우 3.08 보어마그네톤이었으며, I 자형, + 모양 및 H자 모양의 경우 각기 3.09, 3.15, 3.30 보어마그네톤이었다.