• Title/Summary/Keyword: Magnetic intensity

Search Result 890, Processing Time 0.022 seconds

A Study on the Variation of Magnetic Field Intensity and Short Current by Coating Material of Spray in AF Track Circuits (AF궤도회로에서 코팅재에 의한 자계의 세기 및 단락전류 변화에 대한 연구)

  • Kim, Min-Seok;Oh, Sea-Hwa;Park, Yong-Gul;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.552-559
    • /
    • 2011
  • There is a method for offering continuous information by AF track circuits. Magnetic fields are formed by current through rails in the AF track circuit systems. So, the continuous information is received by the magnetic fields on a on-board antenna. Coating materials of spray on rails are researched to decrease defects such as head check, shelling, corrugation, squats and so on in Germany. Currently, a coating method of rail construction is proposed by using the ceramics in Korea. When deciding physical characteristic of the coating material of spray, researches are required about variation of flux density and resistivity by using the coating material of spray. In case that the flux density is much lower than existing value, the information for train control is not transmitted to the on-board antenna. In this paper, inductance on rails is calculated and a model is presented about variation of the magnetic field intensity and resistivity in the AF track circuit. Standard permeability of the coating material of spray is proposed. Also, standard resistivity of the coating material of spray is presented by analyzing short current.

Lymphoepithelial Cyst in Pancreas: a Case Report with Magnetic Resonance Imaging Findings

  • Kim, Hee Jeong;Park, Mi-hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.61-64
    • /
    • 2018
  • Pancreatic lymphoepithelial cysts (LECs) are rare pancreatic cysts with squamous epithelial lining surrounded by dense lymphoid tissue. A preoperative diagnosis of LECs is difficult due to imaging diversity and inadequate documentation because of their rarity. We present a case of surgically confirmed pancreatic LEC with magnetic resonance imaging (MRI) findings as heterogeneous signal intensity on T2-weighted images with multiple septa-like structures, slightly hypo-signal intensity on T1-weighted images, and thin-wall enhancement on dynamic contrast images. LECs are benign lesions without any malignant potential. Therefore, the inclusion of LEC in the differential diagnosis of cystic pancreatic lesions may reduce unnecessary surgical procedures.

Experimental Research of Change in Magnetic Flux Density Due to Load for Measuring KI (응력확대계수측정을 위한 하중에 의한 자속밀도변화의 실험적 연구)

  • Lee, Jeong-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.129-132
    • /
    • 2004
  • In order to determine the effective way of measuring the Mode I stress intensity factor, $K_I$, by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux density above the cracked specimen surface was studied experimentally. The change in magnetic flux in the air above the cracked specimen made of aluminum alloy is measured by changing the load by four-point bending. The magnetic flux in the air is almost not changed by increasing the load in teh specimen. The change in potential drop due to load is not caused by the change in electro-motive force induced in the coiled measuring system. This experimental result agree to the result of theoretical analysis in reference 7).

  • PDF

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

Fabrication and Characteristics of Superconducting Magnetometer

  • Lee, Sang-Heon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.70-72
    • /
    • 2005
  • The relation between electrical properties of YBaCuO ceramic superconductor and externally applied magnetic field was studied. Electrical characteristics of the superconductor with trapped magnetic fluxes are extremely sensitive to the external magnetic field and show the different responses which depend on the direction of the magnetic field. Considering these properties of the superconductor with trapped magnetic fluxes, a magnetic sensor is fabricated. This sensor is able to detect simultaneously both the intensity and the direction of the magnetic field. The sensitivity of the sensor is less than 10$^{-4} T.

Relationship between Hospital Safety Symbol Shapes and Memory (병원 안전 심볼의 형태와 기억과의 관계)

  • Seok-Hwan Bae;Myung-Chul Park;Jae-Sang You;Yong-Gwon Kim;Cheul-Ho Ryoo;Dong-Hyun Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.115-122
    • /
    • 2023
  • The purpose of this study was to examine the association between the shapes and colors of emergency exit symbols, magnetic field warning symbols, and radiation zone symbols used in hospitals for staff and patient safety and their effects on cognitive memory. The hippocampal region's signal intensity(SI) was analyzed using fMRI. The Symbol 2 (1.75±0.54) with a green background had the highest signal intensity (SI) for emergency exits, according to the findings. The black symbol 2 (1.60±0.51) with a yellow background had the highest signal intensity (SI) for the magnetic field warning symbol, followed by the black symbol 1 (1.59±0.65) with an orange background. The black symbol 2 (1.59±0.59) with a yellow background and the black symbol 3 (1.58±0.52) with an orange background had the low signal intensity with slight differences as for the radiation zone symbols. In conclusion, it was determined that the signal intensity of the black symbol with a yellow background was the highest in the magnetic field area and radiation area. This implies that symbols with a high signal intensity (SI) must be utilized intensively. To ensure that the correct meaning of the symbols is communicated in the future, they must also be utilized regularly and continually in disaster safety education.

Effect of non-uniform magnetic field on the thermal behavior and mass transfer in magnetohydrodynamic Czochralski crystal growth of silicon (Magnetic Czochralski 실리콘 단결정 성장에서 열 및 유체유동과 질량전달에 미치는 비균일 자장의 효과)

  • 김창녕
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.555-562
    • /
    • 1998
  • Under the influence of non-uniform magnetic field, melt flow in steady state and oxygen concentration in unsteady state are numerically investigated. The strength of the applied characteristic magnetic fields are B=0.1T, 0.2T, and 0.3T, respectively. The buoyancy effects due to the crucible wall heating and the thermocapillary effects due to the surface tention at the free surface are suppressed differentially by the non-uniform magnetic fields. As the intensity of characteristic magnetic fields is increasing, the recirculation region in the meridional plane is moving toward the growing crystal, and is diminishing. The oxygen concentration on the growing surface of crystals is decreasing and the uniformity of the oxygen concentration is increasing as the intensity of the magnetic fields is increasing.

  • PDF

The Investigation of Magnetic Material Characteristic for Solenoid Valve Development (솔레노이드 밸브 개발을 위한 자성소재 특성 조사)

  • Kim, Byung-Hun;Yi, Moo-Keun;Kwon, Oh-Sung;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.817-820
    • /
    • 2011
  • The solenoid valve is an electro-mechanical device that converts electrical energy into mechanical motion. The magnetic field of solenoid is very closely related to the number of coil winding, the intensity of current and the characteristic of magnetic material. There are disadvantages that the weight and size of valve increase, as increasing the number of coil winding, the intensity of current to augment the magnetic force. Therefore, the selection of magnetic material is very important to reduce the weight and size of solenoid valve.

  • PDF

A Geophysical Study for the Subsurface Structure of the Bomun Basin (보문분지 구조파악을 위한 지구물리탐사)

  • Suh, Man-Cheol;Yun, Hye-Su
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.67-74
    • /
    • 2000
  • Subsurface structure of the Bomun basin was studied along three survey tracks of Line-1, Line-2, and Line-3 using geomagnetic, radioactive, and seismic refraction methods. Abrupt changes found at 2.55 km west and 1.6 km east in the profile of magnetic anomaly along Line-1 are correlated with geologic boundary of the basin. Profiles of radioactive intensity also represent abrupt changes at 2.55 km west of Line-1 and at 1.9 km of Line-2. Cretaceous basement rock has relatively high magnetic anomaly of $200\;{\sim}\;500\;nT$ while sedimentary rocks of the Bomun basin have relatively low magnetic anomaly of $-100\;{\sim}\;+100\;nT$. Radioactive intensity also represents charateristic differences between Cretaceous basement and sedimentary rocks of the Bomun basin. Rocks of Cretaceous basement have lower radioactive intensity than the rocks of the Bomun basin. Magnetic anomaly of of the Bomun basin represents lowest anomaly in western part and increases gradullay toward east. This phenomenon is interpreted as a half graben structure dipping westward. Black shale known by previous studies near the western boundary has high magnetic anomalies and low radioactive intensity. This phenomenon provide a possibility of volcanic rock rather than black shale near the western boundary of the basin along Line-1. Sedimentary layers having velocities of 455 m/s, 1904 m/s, and 2662 m/s are developed to have westward dipping of $2.3^{\circ}$ in the central area of the Bomun basin. The result is consistent with a half-graben model dipping westward which were derieved from magnetic anomaly data.

  • PDF

Theoretical Analysis of Change in Magnetic Flux Density Due to Load for Measuring KI (응력확대계수측정을 위한 하중에 의한 자속밀도변화의 이론적 해석)

  • Lee, Jeong-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.367-371
    • /
    • 2003
  • In order to determine the effective way of measuring the Mode I stress intensity factor for a material containing a two-dimensional surface crack by means of the alternating current potential drop(ACPD) technique, the change in magnetic flux density between crack surfaces and above the specimen surface due to load was studied theoretically. The magnetic flux density in the air between crack surfaces is uniform and above the specimen surface is not changed by increasing the load in the material. Therefore, the change in potential drop due to load in a measuring system which was designed to induce a large amount of electro-motive force was caused by the change in internal inductance of material, the change in the mutual inductance between internal inductance of material and measuring system and the change in the mutual inductance between internal inductance of material and power supply line.

  • PDF