• 제목/요약/키워드: Magnetic head

Search Result 506, Processing Time 0.025 seconds

Computation of Magnetic Thin-Film Head Field with the Boundary Element Method (경계 요소법에 의한 자기 박막 헤드의 자장 계산)

  • Ahn, Chang-Hoi;Lee, Soo-Young;Ra, Jung-Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.50-57
    • /
    • 1989
  • The fringe field of magnetic thin-film head is calculated with the Boundary Element Method (BEM), and the effects of a permeable underlayer to the head field are studied. It is found that the BEM can be efficiently used for this complex problem consisting of three different permeable regions, and the permeable underlayer effectively reduces the length of magnetic flux path and increases the fringe field.

  • PDF

Investigation of Interface between Slider and Plastic Disk for Optical Head (Optical head를 고려 한 slider와 plastic disk의 interface에 대한 연구)

  • 박진무;정구현;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.193-198
    • /
    • 2000
  • Near-field recording NFR), advanced optical storage technology, relies on maintaining a small gap between the optical head and the media. This can be accomplished by utilizing the flying optical head concept as in the magnetic recording. In this research, slider/suspension system and plastic disk are tested for their head/disk interface performance. CSS tests are conducted to monitor the frictional and flying characteristics of sliders.

  • PDF

A Case of Neurilemmoma Originating From Arnold's Nerve (아놀드 신경에서 발생한 외이도의 신경초종 1예)

  • Lee, Oh Hyeong;Park, Jung Mee;Han, Jung Ju;Park, Shi Nae
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.245-249
    • /
    • 2018
  • Neurilemmoma is a benign tumor that originates from the Schwann cell. It frequently occurs in head and neck regions, but neurilemmoma of external auditory canal is extremely rare. Here, we report a very rare case of 36-year-old male with a tumor located in the posterior wall of external auditory canal, preoperatively suspected as neurilemmoma originated from Arnold's nerve by temporal bone magnetic resonance imaging. The tumor mass was surgically excised and pathologically confirmed as a neurilemmoma.

Computer Simulation of Sensing Current Effects on the Magnetic and Magnetoresistance Properties of a Crossed Spin-Valve Read

  • Lim, S.H;Han, S.H;Shin, K.H;Kim, H.J
    • Journal of Magnetics
    • /
    • v.5 no.2
    • /
    • pp.44-49
    • /
    • 2000
  • Computer simulation of sensing current effects on the magnetic and magnetoresistance properties of a crossed spin-valve head is carried out. The spin-valve head has the following layer structure: Ta (8.0 nm)/NiMn (25 nm)/NiFe (2.5 nm)/Cu (3.0 nm)/NiFe (5.5 nm)/Ta (3.0 nm), and it is 1500 nm long and 600 nm wide. Even with a high pinning field of 300 Oe and a high hard-biased field of 50 Oe, the ideal crossed spin-valve structure, which is essential to the symmetry of the output signal and hence high density recording, is not realized mainly due to large interlayer magnetostatic interactions. This problem is solved by applying a suitable magnitude of sensing currents along the length direction generating magnetic fields in the width direction. The ideal spin-valve head is expected to show good symmetry of the output signal. This has not been shown explicitly in the present simulation, however, The reason for this is possibly related to the simple assumption used in this calculation that each magnetic layer consists of a single domain.

  • PDF

Isolated Oculomotor Nerve Palsy Following Minor Head Trauma : Case Illustration and Literature Review

  • Kim, Ealmaan;Chang, Hyukwon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.434-436
    • /
    • 2013
  • Isolated oculomotor nerve palsy (ONP) attributable to mild closed head trauma is a distinct rarity. Its diagnosis places high demands on the radiologist and the clinician. The authors describe this condition in a 36-year-old woman who slipped while walking and struck her face. Initial computed tomography did not reveal any causative cerebral and vascular lesions or orbital and cranial fractures. Enhancement and swelling of the cisternal segment of the oculomotor nerve was seen during the subacute phase on thin-sectioned contrast-enhanced magnetic resonance images. The current case received corticosteroid therapy, and then recovered fully in 13 months after injury. Possible mechanism of ONP from minor head injury is proposed and previous reports in the literature are reviewed.

The optimized recover process of heavy minerals from Korean beach-sand

  • Shin, Hee-Young;Jeon, Ho-Soek;Baik, Seung-Woo;Kim, Wan-Tae;Lee, Jae-Chun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.648-653
    • /
    • 2003
  • Optimized recovery of heavy minerals from the near shore sands of Korean Yellow Sea was investigated using physical processing technologies such as gravity concentration and magnetic separation. The head samples were subjected to the three stages effective separation; Head sample was first treated by a spiral separator to recover rough heavy mineral concentrates, which are contained minerals like ilmenite, zircon and rare earth minerals. Much higher beneficiation processes were subsequently taken by wilfley table and magnetic separation according to their magnetic field responses. Heavy minerals were effectively recovered by wilfley table and subsequent recleaning of heavy minerals by magnetic separations was conducted. Qualitative and relative-quantitative analyses of their constituent elements were doing using XRD and XRF.

  • PDF

Development of multi-repetitive Pulse Compression System for excimer laser excitation (엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구)

  • 전상영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF

Prognostic Value of Computed Tomography and Gradient-echo Magnetic Resonance Imaging in Diffuse Axonal Injury (미만성 축삭 손상에서 전산화단층촬영과 경사에코 자기공명영상을 이용한 예후의 평가)

  • Jung, Nam-Ki;Jin, Sang-Chan;Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.122-131
    • /
    • 2012
  • Purpose: Diffuse axonal injury (DAI) is clinically defined as a coma of over six hours in a head trauma victim without a focal mass lesion. The emergency physician usually resuscitates and stabilizes a comatose head trauma victim in the emergency Department. After assessment and treatment, the prognosis is very important to both the victim and the physician. The prognosis for DAI is based on Glasgow Coma Scale (GCS) and other imaging data. We investigated the prognostic value of computed tomography (CT) and gradient-echo magnetic resonance imaging (GRI) for head trauma victims with DAI. Methods: Fifty-three(53) head trauma victims of DAI were enrolled in this study from 2007 to 2012. During the study period of six years, data on trauma victims were collected retrospectively. We analyzed the differences in the Glasgow Outcome Scale (GOS) result between the CT and the GRI modalities. Results: We classified the study group by using GOS. Between the good outcome subgroup (GOS scores of 4 and 5) and the poor outcome subgroup (GOS score of 1-3), there were no statistical difference in sex, age, initial vital signs and initial GCS score. The good outcome subgroup had non-hemorrhage on CT(52%), which was correlated with good outcome and a shorter awakening time, while a larger number and a deeper location of hemorrhagic lesions on in GRI were correlated with poor outcome in DAI. Conclusion: We conclude that the existence of hemorrhagic lesions on CT, and the number and location of those lesions on GRI had good prognostic value for head trauma victims with DAI.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.