• Title/Summary/Keyword: Magnetic gradient

Search Result 484, Processing Time 0.021 seconds

Gradient Waveform Synthesizer in Magnetic Resonance Imaging System using Digital Signal Processors (DSP를 이용한 자기공명영상시스템의 경사자계 파형 발생기)

  • Go, Gwang-Hyeok;Gwon, Ui-Seok;Kim, Chi-Yeong;Kim, Hyu-Jeong;Kim, Sang-Muk;An, Chang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In this paper, we develop a TMS320C31 (60MHz) digital signal processor (DSP) board to synthesize gradient waveforms for Spiral Scan Imaging (SSI), which is one of the ultra fast magnetic resonance imaging (MRI) methods widely used. In SSI, accurate gradient waveforms are very essential to high quality magnetic resonance images. For this purpose, sampling rate for synthesizing the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP boards accurate gradient waveforms are obtained. Ultra fast spiral scan imaging with the developed with the developed DSP board is currently under development.

  • PDF

A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI (고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교)

  • Goo, Eun-Hoe;Chae, Hong-In;Park, Jong-Bae;Im, Cheong-Hwan;Kim, Jeong-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF

ON RIVLIN-ERICKSON ELASTICO-VISCOUS FLUID HEATED AND SOLUTED FROM BELOW IN THE PRESENCE OF COMPRESSIBILITY, ROTATION AND HALL CURRENTS

  • Gupta, Urvashi;Sharma, Gaurav
    • Journal of applied mathematics & informatics
    • /
    • v.25 no.1_2
    • /
    • pp.51-66
    • /
    • 2007
  • A layer of compressible, rotating, elastica-viscous fluid heated & soluted from below is considered in the presence of vertical magnetic field to include the effect of Hall currents. Dispersion relation governing the effect of viscoelasticity, salinity gradient, rotation, magnetic field and Hall currents is derived. For the case of stationary convection, the Rivlin-Erickson fluid behaves like an ordinary Newtonian fluid. The compressibility, stable solute gradient, rotation and magnetic field postpone the onset of thermosolutal instability whereas Hall currents are found to hasten the onset of thermosolutal instability in the absence of rotation. In the presence of rotation, Hall currents postpone/hasten the onset of instability depending upon the value of wavenumbers. Again, the dispersion relation is analyzed numerically & the results depicted graphically. The stable solute gradient and magnetic field (and corresponding Hall currents) introduce oscillatory modes in the system which were non-existent in their absence. The case of overstability is discussed & sufficient conditions for non-existence of overstability are derived.

Buffer-Optimized High Gradient Magnetic Separation: Target Cell Capture Efficiency is Predicted by Linear Bead-Capture Theory

  • Waseem, Shahid;Udomsangpetch, Rachanee;Bhakdi, Sebastian C.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.125-132
    • /
    • 2016
  • High gradient magnetic separation (HGMS) is the most commonly used magnetic cell separation technique in biomedical science. However, parameters determining target cell capture efficiencies in HGMS are still not well understood. This limitation leads to loss of information and resources. The present study develops a bead-capture theory to predict capture efficiencies in HGMS. The theory is tested with CD3- and CD14-positive cells in combination with paramagnetic beads of different sizes and a generic immunomagnetic separation system. Data depict a linear relationship between normalized capture efficiency and the bead concentration. In addition, it is shown that key biological functions of target cells are not affected for all bead sizes and concentrations used. In summary, linear bead-capture theory predicts capture efficiency ($E_t$) in a highly significant manner.

Research and development of new magnetic filter for high gradient magnetic separation

  • Shigehiro Nishijima;Naoki Nomura;Fumihito Mishima
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.1-6
    • /
    • 2023
  • We have been developing a new magnetic filter so that small sized paramagnetic substances can be separated even in a low magnetic field (lower than 2T). The developed filter is a packed ferromagnetic filament with a triangular cross section. The filament has a diameter of 120 ㎛ and a length of 3 mm, and is mechanically packed with a volume ratio of 17.6%. Using this filter, a magnetic separation experiment of hematite was carried out using a superconducting magnet at the field of 2T. Similarly, magnetic separation was performed using a conventional magnetic filter. It became clear that the separation efficiency of newly developed filter is high as that of conventional mesh filter. The smaller sized hematite (<3 ㎛) could be separated though conventional mesh filter could not separate.

A Review on Nuclear Magnetic Resonance Logging: Simulation Schemes (자기공명반응 시뮬레이션 해설 및 비교)

  • Jang, Jae Hwa;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.97-105
    • /
    • 2013
  • Nuclear magnetic resonance (NMR) logging has become an important technique for formation evaluation, detecting interaction signals between H protons and applied magnetic fields. Measured decay signals called relaxation, contain important information about density of H protons and different decay rate due to its fluid type in the sensitive area. Thus, petrophysical information such as porosity, permeability and wettability can be estimated through the interpretation of the decay signals. Many researches on random walk simulation have been published, since a simulation method based on random walk for solving exponential decays was adapted in the early of 1950. This study first makes a review on NMR simulation researches, explains two most important methods: simulation with or without considering magnetic field gradient. Lastly, the study makes a comparison between NMR simulation responses with and without magnetic field gradient to show the importance to consider magnetic gradient to analyze the effects of magnetic gradients on NMR responses.

Cross Correlated Effects of Radiation Damping and the Distant Dipolar Field with a Pulsed Field Gradient in Solution NMR

  • Chung Kee-Choo;Ahn Sang-Doo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.46-58
    • /
    • 2006
  • With a simple pulse sequence ($\pi/2$-{gradient, duration T}-acquisition) in solution NMR, detected signal has slowly grown up to percents of the equilibrium magnetization. The source of this unusual resurrection of dephased magnetization after a crushed gradient is cross-correlated effects of radiation damping and the distant dipolar field, which has been demonstrated by a numerical simulation and theoretical analysis.

  • PDF

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

Dynamic analysis of functionally graded (FG) nonlocal strain gradient nanobeams under thermo-magnetic fields and moving load

  • Alazwari, Mashhour A.;Esen, Ismail;Abdelrahman, Alaa A.;Abdraboh, Azza M.;Eltaher, Mohamed A.
    • Advances in nano research
    • /
    • v.12 no.3
    • /
    • pp.231-251
    • /
    • 2022
  • Dynamic behavior of temperature-dependent Reddy functionally graded (RFG) nanobeam subjected to thermomagnetic effects under the action of moving point load is carried out in the present work. Both symmetric and sigmoid functionally graded material distributions throughout the beam thickness are considered. To consider the significance of strain-stress gradient field, a material length scale parameter (LSP) is introduced while the significance of nonlocal elastic stress field is considered by introducing a nonlocal parameter (NP). In the framework of the nonlocal strain gradient theory (NSGT), the dynamic equations of motion are derived through Hamilton's principle. Navier approach is employed to solve the resulting equations of motion of the functionally graded (FG) nanoscale beam. The developed model is verified and compared with the available previous results and good agreement is observed. Effects of through-thickness variation of FG material distribution, beam aspect ratio, temperature variation, and magnetic field as well as the size-dependent parameters on the dynamic behavior are investigated. Introduction of the magnetic effect creates a hardening effect; therefore, higher values of natural frequencies are obtained while smaller values of the transverse deflections are produced. The obtained results can be useful as reference solutions for future dynamic and control analysis of FG nanobeams reinforced nanocomposites under thermomagnetic effects.

Development of superconducting high gradient magnetic separation system for scale removal from feed-water in thermal power plant

  • Shibatani, Saori;Nakanishi, Motohiro;Mizuno, Nobumi;Mishima, Fumihito;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Maeda, Tatsumi;Shigemoto, Naoya;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.19-22
    • /
    • 2016
  • A Superconducting High Gradient Magnetic Separation (HGMS) system is proposed for treatment of feed-water in thermal power plant [1]. This is a method to remove the iron scale from feed-water utilizing magnetic force. One of the issues for practical use of HGMS system is to extend continuous operation period. In this study, we designed the magnetic filters by particle trajectory simulation and HGMS experiments in order to solve this problem. As a result, the quantity of magnetite captured by each filter was equalized and filter blockage was prevented. A design method of the magnetic filter was proposed which is suitable for the long-term continuous scale removal in the feed-water system of the thermal power plant.