• 제목/요약/키워드: Magnetic flow

검색결과 778건 처리시간 0.024초

자기장하의 액체금속 유동의 차압 측정 (MHD Pressure Drop of a Liquid-Metal Flow under a Transverse Magnetic Field)

  • 차재은;김희령;김종만;남호윤;김성오;김병호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2638-2641
    • /
    • 2007
  • The magnetohydrodynamic(MHD) pressure drop along a liquid sodium flow was measured in a rectangular duct under a transverse magnetic field. The test section was made of a 3 mm thick stainless steel SUS304 with a $74{\times}5mm^2$ rectangular flow channel. The range of experimental parameters was roughly B=0${\sim}$0.18T and U=0${\sim}$0.9m/s at around $200^{\circ}C$. The differential pressure was measured by a diaphragm seal-type pressure transmitter filled with a high temperature silicon oil within 0.1MPa. The experimental results show a similar pressure drop with the theoretical estimation according to a change of the flow velocity and the magnetic field.

  • PDF

자기장 분포가 확산화염의 연소특성에 미치는 영향: 자기장 On/Off 주기와 Duty Ratio의 역할 (The Influence of Magnetic Field on Diffusion Flames: Role of Magnetic Field On/Off Frequency and Duty Ratio)

  • 이원남;배승만
    • 한국연소학회지
    • /
    • 제17권1호
    • /
    • pp.58-65
    • /
    • 2012
  • The influence of magnetic field on propane and acetylene diffusion flames have been experimentally investigated using an electromagnetic system. Periodically induced magnetic field having various frequencies and duty ratios was established in square wave form. The maximum intensity and gradient of magnetic field were 1.3 T and 0.27 T/mm, respectively. The width of a propane flame was reduced up to 4.5% and the brightness was enhanced up to 25% when the magnetic field was induced. The soot emission from an acetylene flame was ceased when magnetic field was induced. The alteration of flow field, which is due to the paramagnetic characteristics of oxygen molecule, is most likely to be responsible for the change in flame size and brightness. The effect of magnetic field on diffusion flames, which competes with the gravitational effect, was more apparent from a smaller size flame. The magnetic field effect, therefore, could be important under microgravity conditions. Since the time required to alter the flow field must be finite, the magnetic field effect is likely to be less significant for a periodically oscillating magnetic field at a high frequency or having a small duty ratio.

점성유체에 분산된 타원형 야누스 입자의 자성 상호작용에 관한 직접수치해석 (Direct Simulation of the Magnetic Interaction of Elliptic Janus Particles Suspended in a Viscous Fluid)

  • 김희은;강태곤
    • 대한기계학회논문집B
    • /
    • 제41권7호
    • /
    • pp.455-462
    • /
    • 2017
  • 외부자기장에 의한 타원형 야누스 자성입자 사이의 자성 상호작용을 직접수치해석을 사용하여 분석하였다. 유한요소법에 기초한 가상영역법을 사용하여 입자계 유동해석을 수행하였고, 자기장 문제에서는 자성 포텐셜에 대한 지배방정식을 입자와 유체를 포함하는 전체영역에 대하여 풀어 자기장을 구하였다. 이 때 구해진 자기장으로부터 구한 맥스웰 응력을 사용하여 개별 입자에 작용하는 자기력이 계산된다. 입자의 운동과 최종적인 조립구조는 입자의 형상비, 개별 입자의 배향, 입자의 초기 분포에 크게 영향을 받는 것이 확인되었다. 또한 입자의 배향은 입자 주위의 유체 유동에도 영향을 주었다. 외부자기장에 의한 타원형 야누스 입자의 최종 조립구조는 앞서 언급한 인자들에 의해서 영향을 받은 것을 수치해석을 통해 확인할 수 있었다.

전자석 액츄에이터를 이용한 구 주위의 유동제어 (Active control of flow over a sphere using electro-magnetic actuators)

  • 박진일;최해천;전우평
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.497-501
    • /
    • 2000
  • Flow over a sphere is controlled experimentally at $Re=10^5$ using electro-magnetic actuators. The electro-magnetic actuator developed in this study is composed of the permanent magnet electro-magnet membrane and slot. Eight actuators are placed inside the sphere at equally spaced intervals on a latitudinal plane and the position of the control slot is 76 from the stagnation point. Each actuator generates a periodic blowing and suction through the slot at variable frequencies of $10{\sim}140Hz$ and variable amplitudes by controlling electric signals applied to the electro-magnet. Drag on the sphere measured using a load cell is significantly reduced with control at the forcing frequencies larger than the natural shedding frequency $({\approx}14Hz\;at\;Re=10^5)$, whereas drag is slightly increased at the forcing frequency of 10Hz. It is shown from pressure measurement that the static pressure in the rear surface of the sphere is significantly increased with control, indicating that the separation is delayed due to control. Flow visualizations also show that the detaching shear layer is more attracted to the sphere center with control, the separation bubble size is significantly reduced, and motion inside the bubble is very weak, as compared to the case of uncontrolled flow.

  • PDF

MR 유체의 자기유동 특성에 대한 실험연구 (Experimental study on Magnetic Flow Characteristics of MR Fluid)

  • 이석현;김기영;백대성;권영철;박삼진
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3611-3616
    • /
    • 2013
  • MR 유체의 물리특성은 자기장에 의해 영향을 받는다. 본 연구에서는 MR 유체의 자기장에 의한 유동변화를 실험적으로 조사하고자, MR 유체의 밀도와 점도를 변경하면서 자기장에 의한 유동 가시화와 전단응력 변화를 측정하였다. 이를 위해 밀도 3종, 점도 3종에 대한 MR 유체를 제조하였고 MR 유체 가시화 실험장치를 제작하였다. 자기장이 인가되면, MR 유체 파우더의 유동흐름은 띠를 형성하면서 자기장이 인가되지 않은 경우와는 다른 유동흐름을 보여주었다. 또한 전단응력은 인가전류와 밀도가 높을수록 더 크게 증가하였으며, 인가전류 2.0A에서 MR 유체의 밀도가 $1300kg/m^3$에서 $1700kg/m^3$ 로 변하면 전단응력은 33% 정도 증가하였다.

On the Association Between Sub-photospheric Flows and Photospheric Magnetic Fields of Solar Active Regions

  • ;채종철
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.86.2-86.2
    • /
    • 2012
  • We present the study of association between sub-photospheric flow and photospheric magnetic fields of active regions respectively derived from the local helioseismology and observed magnetic fields. It is believed that the energetic transients, e.g., flares and CMES, are caused by changes in magnetic and velocity field topologies in solar atmosphere. These changes are essentially brought about by the magnetic fields that are rooted beneath the photosphere where they interact and get affected by sub-photospheric flows. Therefore, we expect the topology of sub-surface flows to be correlated with the observable topology of magnetic fields at the photosphere and higher layers. In order to examine the correlation, if any, we computed the near photospheric flows and photospheric magnetic fields using the Doppler velocity and magnetic fields observations, respectively, provided by the SDO/HMI. The high resolution Doppler observations from the HMI enabled us to compute the very high p-modes parameters which sample the sub-photosphere shallow near the photosphere. Furthermore, we compute the sub-photospheric flow topology parameters, e.g., vorticity, kinetic helicity, and photospheric magnetic field topology parameters, e.g., magnetic helicity, from the magnetic fields observations to compare their associations. We present the result of the analysis in the paper.

  • PDF

소용량 교류 MHD발전기에 대한 실험적 연구 (Experiment on Small A.C. MHD Power Generator)

  • 전춘생
    • 전기의세계
    • /
    • 제25권5호
    • /
    • pp.79-87
    • /
    • 1976
  • This paper is to investigate the A.C generation of MHD engine, converting directly the kinetic energy of conductive gas in high temperature to electric power by the effect of magnetic field. It is known that there are at least two kinds of method in A.C MHD power generation; one, by sending stationary plasma flow in an alternating or rotating magnetic field and the other, by transmission of pulse type plasma flow in uniform and constant magnetic field, former method is adopted here. In order to raise the total efficiency of close cycle in combination with nuclear power and MHD genertaion, an argon plasma jet is utilized as heat source, which is not mixed with the seed material, and the design data are obtained for A.C MHD generation in small capacity, but induced voltage and power output have the maximum values, 15 voltages and 7.5W respectively due to plasma flow with low conductivity and weak magnetic field.

  • PDF

축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발 (A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing)

  • 안치범;문기철;정기석;남경원;이정주;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

Thermal radiation and some physical combined effects on an asymmetric peristaltically vertical channel of nanofluid flow

  • Amira S. Awaad;Zakaria M. Gharsseldien
    • Advances in nano research
    • /
    • 제16권6호
    • /
    • pp.579-591
    • /
    • 2024
  • This study explained the effects of radiation, magnetic field, and nanoparticle shape on the peristaltic flow of an Upper-Convected Maxwell nanofluid through a porous medium in an asymmetric channel for a better understanding of cooling and heating mechanisms in the presence of magnetic fields. These phenomena are modeled mathematically as a system of non-linear differential equations, that are solved under long-wavelength approximation and low Reynolds number conditions using the perturbation method. The results for nanofluid and temperature described the behavior of the pumping characteristics during their interaction with (the vertical position, thermal radiation, the shape of the nanoparticle, and the magnetic field) analytically and explained graphically. Also, the combined effects of thermal radiation parameters and some physical parameters on pressure rise, pressure gradient, velocity, and heat distribution are pointed out. Qualitatively, a reverse velocity appears with combined high radiation and Grashof number or combined high radiation and low volume flow rate. At high radiation, the spherical nanoparticle shape has the greatest effect on heat distribution.

MR PC 영상을 이용한 유체 흐름 분석 (Measurement of Flow Velocity and Flow Visualization with MR PC Image)

  • 김수정;이동혁;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF