• Title/Summary/Keyword: Magnetic field intensity

Search Result 337, Processing Time 0.024 seconds

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

A Study of Nondestructive Evaluation Using Scan type Magnetic Camera

  • Hwang, Ji-Seong;Lee, Jin-Yi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1830-1835
    • /
    • 2005
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. And it is possible to interpret the distribution of the magnetic field when the dipole model is introduced. This study introduces the numerical and experimental considering of the quantitative evaluation of several size and shapes of the cracks using the magnetic field images of the scan type magnetic camera.

  • PDF

Harmonic Rotational Magnetic Field Calculation with the Finite Element Method and the Permeability Tensor (유한요소법과 투자율 텐서를 이용한 고조파 회전자계 계산)

  • 이창환;김홍규;정현교;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.159-165
    • /
    • 1997
  • Recently, many researchers are interested in the analysis of the magnetic fields considering the vector relation between the magnetic flux density and the magnetic field intensity. In this paper, Finite Element Method with two dimensional tensor permeability is adopted to calculate the magnetic field quantities in the system having the rotational magnetic field. In addition, the method of analyzing the magnetic field considering the harmonic components is introduced. The validity of the proposed method is proved compared with the experimental results.

  • PDF

GMI Magnetic Field Sensor based on Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2009.12a
    • /
    • pp.217-219
    • /
    • 2009
  • A GMI magnetic field sensor working based on time-coded principle has been investigated and designed. The laboratory model has been constructed and tested carefully, demonstrating the sensitivity of $3\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. An amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ in length, was chosen to be sensing element which was fit into a small field modulation coil of 60 mm in length. The sensor is working based on a time-coded principle that, with the magnetic field modulation was chosen in range of hundreds of Hz, the change in time interval of two adjacent GMI peaks relating to external DC magnetic field is proportional to the intensity of the external field to be measured. This mechanism has made a great improvement to the linearity of the sensor.

  • PDF

Low Magnetic Field MRI Visibility of Rubber-Based Markers

  • Kim, Jeong Ho;Jung, Seongmoon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.89-93
    • /
    • 2019
  • Purpose: This study aims to develop new markers based on silicone rubber and urethane rubber to enhance visibility in low magnetic field magnetic resonance (MR) imaging. Methods: Four types of markers were fabricated using two different base materials. Two of the markers were composed of two different types of silicone rubber: DragonSkin™ 10 MEDIUM and BodyDouble™ SILK. The other two markers were composed of types of urethane rubber: PMC™ 780 DRY and VytaFlex™ 20. Silicone oil (KF-96 1000cs) was added to the fabricated markers. The allocated amount of oil was 20% of the weight (wt%) of each respective marker. The MR images of the markers, with and without the silicone oil, were acquired using MRIdian with a low magnetic field of 0.35 T. The signal intensities of each MR image for the markers were analyzed using ImageJ software and the visibility for each was compared. Results: The highest signal intensity was observed in VytaFlex™ 20 (279.67±3.57). Large differences in the signal intensities (e.g., 627% in relative difference between BodyDouble™ SILK and VytaFlex™ 20) among the markers were observed. However, the maximum difference between the signal intensities of the markers with the silicone oil showed only a 62% relative difference between PMC™ 780 DRY and DragonSkin™ 10 MEDIUM. An increase in the signal intensity of the markers with the silicone oil was observed in all markers. Conclusions: New markers were successfully fabricated. Among the markers, DragonSkin™ 10 MEDIUM with silicone oil showed the highest MR signal intensity.

Analysis of an HTS coil for large scale superconducting magnetic energy storage

  • Lee, Ji-Young;Lee, Seyeon;Choi, Kyeongdal;Park, Sang Ho;Hong, Gye-Won;Kim, Sung Soo;Lee, Ji-Kwang;Kim, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.45-49
    • /
    • 2015
  • It has been well known that a toroid is the inevitable shape for a high temperature superconducting (HTS) coil as a component of a large scale superconducting magnetic energy storage system (SMES) because it is the best option to minimize a magnetic field intensity applied perpendicularly to the HTS wires. Even though a perfect toroid coil does not have a perpendicular magnetic field, for a practical toroid coil composed of many HTS pancake coils, some type of perpendicular magnetic field cannot be avoided, which is a major cause of degradation of the HTS wires. In order to suggest an optimum design solution for an HTS SMES system, we need an accurate, fast, and effective calculation for the magnetic field, mechanical stresses, and stored energy. As a calculation method for these criteria, a numerical calculation such as an finite element method (FEM) has usually been adopted. However, a 3-dimensional FEM can involve complicated calculation and can be relatively time consuming, which leads to very inefficient iterations for an optimal design process. In this paper, we suggested an intuitive and effective way to determine the maximum magnetic field intensity in the HTS coil by using an analytic and statistical calculation method. We were able to achieve a remarkable reduction of the calculation time by using this method. The calculation results using this method for sample model coils were compared with those obtained by conventional numerical method to verify the accuracy and availability of this proposed method. After the successful substitution of this calculation method for the proposed design program, a similar method of determining the maximum mechanical stress in the HTS coil will also be studied as a future work.

Design of Magneto-Rheological Clutch Coil Operation Unit using Electro Magnetic Field Analysis (전자기장 해석을 이용한 자기점성 유체 클러치 코일 작동부 설계)

  • Song, Jun-Han;Choi, Dook-Hwan;Chun, Chong-Keun;Kwon, Young-Chul;Lee, Tae-Haeng
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.22-28
    • /
    • 2009
  • Recently, there has been an active study about smart fluid to control the vibration, in which MR fluid is evaluated as most efficient because it can generate different bonding forces based on the intensity of the external magnetic fields. This paper attempts to find a mechanism that, under limited conditions during a clutch production that uses such dynamic characteristic, defects the maximum intensity of electromagnetism. Using the finite element analysis program, we predicted a change within the bonding force of the MR fluid occurring inside the clutch when it is subjected to an increased electric current. In addition, we analyzed the change in the magnetic intensity when the coil comprising the coil control center is switched to multiple lines from the standard single line, to find a mechanism that can maximize the effect. Based on this analysis, we developed the clutch and tested its function, hoping to widen future MR fluid's range of application.

Magnetic Properties of MTJ by Capping Material & External Field Intensity (Capping Material & External Field Intensity에 따른 자기 저항 특성 연구)

  • 이계남;장인우;박영진;박상용;이재형;전경인;신경호
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.50-51
    • /
    • 2002
  • 최근 실온에서 약 40% 이상의 높은 자기저항(magnetoresistance, MR)을 나타내는 자기 터널 접합(magnetic tunnel junction, MTJ)이 보고되면서 비휘발성 자기메모리로의 응용을 눈앞에 두고 있다.[1]. 이에 본 실험에서는 Substrate / Ta (base electrode) / NiFe / PtMn (AF pinning layer) / CoFe (pinned) / Ru / CoFe (fixed) / Al-O/ CoFe (free) / NiFe (free) / Ta & Ru (Capping Layer)과 같은 MTJ 증착 구조를 사용하여, MTJ의 보다 향상된 특성을 확보하기 위한 노력으로서 Al-O 두께, 어닐링 조건(Field Intensity & Sequence)변화 등을 시도하였다. (중략)

  • PDF

INTENSITY AND DOPPLER VELOCITY OSCILLATIONS IN PORE ATMOSPHERE

  • Cho, Kyung-Suk;Bong, Su-Chan;Nakariakov, Valery;Lim, Eun-Kyung;Park, Young-Deuk;Chae, Jongchul;Yang, Heesu;Park, Hyung-Min;Yurchyshyn, Vasyl
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.98-98
    • /
    • 2014
  • Due to the simple vertical structure of magnetic field, pores can be exploited to study the transport of mechanical energy by waves along the magnetic field to the chromosphere and corona. For a better understanding of physics of pores, we have investigated chromospheric traveling features running across two merged pores from their centers at the speed about 55 km s-1, in the active region AR 11828. The pores were observed on 2013 August 24 by using high time, spatial, and spectral resolution data from the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST). We infer a LOS velocity by applying the bisector method to the Ca II $8542{\AA}$ band and $H{\alpha}$ band, and investigate intensity and the line-of-sight velocity changes at different wavelengths and different positions at the pores. We find that they have 3 minutes oscillations, and the intensity oscillation from the line center is preceded by that from the core ($-0.3{\AA}$) of the bands. There is no phase difference between the intensity and the LOS velocity oscillations at a given wavelength. The amplitude of LOS velocity from near the core spectra is greater than that from the far core spectra. These results support the interpretation of the observed wave as a slow magnetoacoustic wave propagating along the magnetic field lines in the pores. The apparent horizontal motion and a sudden decrease of its speed beyond the pores can be explained by the projection effect caused by inclination of the magnetic field with a canopy.

  • PDF

Relationship between Hospital Safety Symbol Shapes and Memory (병원 안전 심볼의 형태와 기억과의 관계)

  • Seok-Hwan Bae;Myung-Chul Park;Jae-Sang You;Yong-Gwon Kim;Cheul-Ho Ryoo;Dong-Hyun Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.115-122
    • /
    • 2023
  • The purpose of this study was to examine the association between the shapes and colors of emergency exit symbols, magnetic field warning symbols, and radiation zone symbols used in hospitals for staff and patient safety and their effects on cognitive memory. The hippocampal region's signal intensity(SI) was analyzed using fMRI. The Symbol 2 (1.75±0.54) with a green background had the highest signal intensity (SI) for emergency exits, according to the findings. The black symbol 2 (1.60±0.51) with a yellow background had the highest signal intensity (SI) for the magnetic field warning symbol, followed by the black symbol 1 (1.59±0.65) with an orange background. The black symbol 2 (1.59±0.59) with a yellow background and the black symbol 3 (1.58±0.52) with an orange background had the low signal intensity with slight differences as for the radiation zone symbols. In conclusion, it was determined that the signal intensity of the black symbol with a yellow background was the highest in the magnetic field area and radiation area. This implies that symbols with a high signal intensity (SI) must be utilized intensively. To ensure that the correct meaning of the symbols is communicated in the future, they must also be utilized regularly and continually in disaster safety education.