• 제목/요약/키워드: Magnetic control

검색결과 2,269건 처리시간 0.027초

Skin Effect of Rotating Magnetic Fields in Liquid Bridge

  • Zhang, Yi;Zeng, Zhong;Yao, Liping;Yokota, Yuui;Kawazoe, Yoshi;Yoshikawa, Akira
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.333-343
    • /
    • 2017
  • A rotating magnetic field (RMF) ${\Phi}_1-{\Phi}_2$ model was developed in consideration of the skin effect. The rotating magnetic field's induced three-dimensional flow was simulated numerically, and the influence of the skin effect was investigated. The rotating magnetic field drives the rotating convection in the azimuthal direction, and a secondary convection appears in the radial-meridional direction. The results indicate that ignoring the skin effect results in a smaller azimuthal velocity component and larger radial and axial velocity components, and that the deviation becomes more obvious with the larger dimensionless shielding parameter K.

Calculation of Leakage Inductance of Integrated Magnetic Transformer with Separated Secondary Winding Used in ZVS PSFB Converter

  • Tian, Jiashen;Zhang, Yiming;Ren, Xiguo;Wang, Xuhong;Tao, Haijun
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.644-651
    • /
    • 2016
  • A novel zero voltage switching (ZVS) phase shift full bridge (PSFB) converter used in geophysical exploration is proposed in this paper. To extend the ZVS ranges and increase power density of the converter, external inductor acting as leakage inductance is applied and integrated into the integrated magnetic (IM) transformer with separated secondary winding. Moreover, the loss of ZVS PSFB converter is also decreased. Besides, the analysis and accurate prediction methodology of the leakage inductance of the IM transformer are proposed, which are based on magnetic energy and Lebedev. Finally, to verify the accuracy of analysis and methodology, the experimental and finite element analysis (FEA) results of IM transformer and 40 kW converter prototypes are given.

전자기 액튜에이터를 이용한 1/4차량 모델의 능동 진동 제어에 관한 연구 (Active Vibration Control of 1/4 Vehicle Model using Electro-magnetic Actuator)

  • 허신;최강윤;김유일
    • 연구논문집
    • /
    • 통권23호
    • /
    • pp.81-92
    • /
    • 1993
  • In this study, quarter vehicle model is used to analyse vibration control effects for ride comfort and handling safety according to this three kinds of control methods, which are the modal control, the sky-hook control and the linear viscous damping control. We performed theoretical analysis and experiments and compared two results. In experiments, electro-magnetic actuator was employed as a force actuator. It is shown that all three methods can effectively control the vehicle model. The modal control method gives similar control results using gain less than the viscous damping control.

  • PDF

극 영역을 고려한 횡축형 자기 베어링 시스템의 로버스트 제어 (Robust Control of Horizontal-Shaft Magnetic Bearing System considering Pole Assignment Region)

  • 김창화;추만석;양주호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.21-21
    • /
    • 2000
  • In this paper, we design the state feedback gain using linear matrix inequality(LMI) to the multiobjective synthesis, in the magnetic bearing system with integral type servo system. The design objectives can be a H$\_$$\infty$/ performance, asymptotic disturbance rejection, time-domain constraints, on the closed-lnp pole location. To the end, we investigated the validity of the designed controller through results of simulation.

  • PDF

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

General Analytical Method for Magnetic Field Analysis of Halbach Magnet Arrays Based on Magnetic Scalar Potential

  • Jin, Ping;Yuan, Yue;Lin, Heyun;Fang, Shuhua;Ho, S.L.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.95-104
    • /
    • 2013
  • This paper presents a general analytical method for predicting the magnetic fields of different Halbach magnet arrays with or without back iron mounted on slotless permanent magnet (PM) linear machines. By using Fourier decomposition, the magnetization components of four typical Halbach magnet arrays are determined. By applying special synthetic boundary conditions on the PM surfaces, the expressions of their magnetic field distributions are derived based on the magnetic scalar potential (MSP), which are simpler than those based on the magnetic vector potential (MVP). The correctness of the method is validated by finite element analysis. The harmonics of airgap flux density waveforms of these Halbach magnet arrays with or without back iron are also compared and optimized.

자기 부상계의 변위추정 회로설계에 관한 연구 (A Study on the Gap Estimation Circuit Design of the Magnetic Levitation System)

  • 김창화;하영원;심성효;양주호
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.144-153
    • /
    • 1997
  • The magnetic levitation system is utilized in the magnetic bearing of high-speed rotor because of little friction, no lubrication, no noise and so on. The magnetic levitation system need the feedback controller for the stabilization of system, and gap sensors are generally used to measure the gap. The use of gap sensors brings out the increase of the number of troublesome, and the decrease of the control performance because of the dislocation between the measurement point and the control point. This paper presents the design of the gap estimation circuit for the sensorless method proposed by authors in the magnetic levitation system. We made the gap estimation circuit which was composed of both the superposition circuit and the measuring circuit. And we investigated the validity of the usefulness of the proposed sensorless method in the magnetic levitation system through results of actual experiment.

  • PDF

자기부상 물류이송시스템 설계에 관한 연구 (A Study on the Design of Logistics Transportation System using Magnetic Levitation)

  • 최대규;조재훈;김용태
    • 한국지능시스템학회논문지
    • /
    • 제24권2호
    • /
    • pp.129-135
    • /
    • 2014
  • 본 논문에서는 이동할 때 마찰이 없고 소음이나 먼지가 발생하지 않는 자기부상 물류이송시스템의 설계 방법을 제안한다. 제안된 자기부상 이송시스템은 크게 부상시스템과 추진시스템으로 구분된다. 자기부상시스템은 레일로 전자석을 끌어당기는 흡인식 부상시스템으로 구현하였으며, PID 제어기를 사용하여 전자석 공급 전류를 제어하였다. 자기부상 이송시스템의 추진시스템에는 바퀴의 마찰과 모터의 회전이 없고 소음이 최소화 되는 선형 유도전동기를 사용하였다. 추진시스템의 제어방법은 입력되는 직류전압에서 큰 교류전압을 얻을 수 있는 공간벡터 펄스폭 변조방식을 적용하였다. 제안한 자기부상 물류이송시스템은 부상 및 추진 제어 실험을 통하여 성능을 검증하였다.

자기유변탄성체의 마찰제어적용 연구 (Application Study of Magneto-Rheological Elastomer to Friction Control)

  • 연성룡;이득원;이광희;이철희;김철현;조원오
    • Tribology and Lubricants
    • /
    • 제28권3호
    • /
    • pp.107-111
    • /
    • 2012
  • In this study, application feasibility of Magneto-rheological elastomer to friction control is investigated to identify the reciprocating friction and wear performance in applied magnetic field. Friction and wear of MR elastomerare measured by reciprocating tester by controlling the magnetic field. In the case of applied magnetic field, the coefficient of friction increases as both load and velocity increase. For the case of no magnetic field, the value of coefficient of friction hardly changes during the test. The amount of destruction is measured through cross section images of MR elastomer after tests. The depths of destruction are compared for MR elastomer with or without magnetic field. The results show that the depth of destruction of MR elastomer with magnetic field is deeper than without magnetic field. Based on the obtained results, optimal braking and driving performance can be achieved by controlling the coefficient of friction of MR elastomer, which can be applied to various industrial applications such as driving systems of automobiles and robots.

Minimum-Time Attitude Reorientations of Three-Axis Stabilized Spacecraft Using Only Magnetic Torquers

  • Roh, Kyoung-Min;Park, Sang-Young;Choi, Kyu-Hong;Lee, Sang-Uk
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권2호
    • /
    • pp.17-27
    • /
    • 2007
  • Minimum-time attitude maneuvers of three-axis stabilized spacecraft are presented to study the feasibility of using three magnetic torquers perform large angle maneuvers. Previous applications of magnetic torquers have been limited to spin-stabilized satellites or supplemental actuators of three axis stabilized satellites because of the capability of magnetic torquers to produce torques about a specific axes. The minimum-time attitude maneuver problem is solved by applying a parameter optimization method for orbital cases to verify that the magnetic torque system can perform as required. Direct collocation and a nonlinear programming method with a constraining method by Simpson's rule are used to convert the minimum-time maneuver problems into parameter optimization problems. An appropriate number of nodes is presented to find a bang-bang type solution to the minimum-time problem. Some modifications in the boundary conditions of final attitude are made to solve the problem more robustly and efficiently. The numerical studies illustrate that the presented method can provide a capable and robust attitude reorientation by using only magnetic torquers. However, the required maneuver times are relatively longer than when thrusters or wheels are used. Performance of the system in the presence of errors in the magnetometer as well as the geomagnetic field model still good.