• Title/Summary/Keyword: Magnetic component

Search Result 509, Processing Time 0.024 seconds

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Magnetic Shielding Effect on Halbach Cylinder used in Magnetic Refrigerators

  • Baek, Un Bong;Lee, Jong Suk;Yu, Seong-Cho;Ryu, Kwon-Sang
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.349-352
    • /
    • 2014
  • The system for producing magnetic field constitutes an important component of magnetic refrigerator. Many researchers have directed significant effort to increase the magnetic field intensity, because the magnetocaloric effect at the Curie temperature increases with the power of 2/3 of the magnetic field. In this study, we report the simulation of the magnetic field intensity at polar axis of a Halbach cylinder (HC) by i) changing the length and thickness of the HC, ii) having with or without gap of the HC, and iii) surrounding the HC with a soft magnet shell, acting as a shielding. We simulated the field distribution of a HC with a finite size. Furthermore, the detailed numerical results of the magnetic field distribution and its dependence on shielding are presented in this study.

X-ray scattering study on the electric field-induced interfacial magnetic anisotropy modulation at CoFeB / MgO interfaces

  • Song, Kyung Mee;Kim, Dong-Ok;Kim, Jae-Sung;Lee, Dong Ryeol;Choi, Jun Woo
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1212-1217
    • /
    • 2018
  • The electric field-induced modifications of magnetic anisotropy in CoFeB/MgO systems are studied using X-ray resonant magnetic scattering and magneto-optical Kerr effect. Voltage dependent changes of the magnetic anisotropy of -12.7 fJ/Vm and -8.32 fJ/Vm are observed for Ta/CoFeB/MgO and Hf/CoFeB/MgO systems, respectively. This implies that the interfacial perpendicular magnetic anisotropy is reduced (enhanced) when electron density is increased (decreased). X-ray resonant magnetic scattering measurements reveal that the small in-plane magnetic component of the remanent state of CoFeB/MgO systems with weak magnetic anisotropy changes depending on the applied voltage leading to modification of the magnetic anisotropy at the CoFeB/MgO interface.

Morningside Pi2 Pulsation Observed in Space and on the Ground

  • Ghamry, Essam
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In this study, we examined a morningside Pi2 pulsation, with a non-substorm signature, that occurred in very quiet geomagnetic conditions (Kp = 0) at 05:38 UT on December 8, 2012, using data obtained by Van Allen Probes A and B (VAP-A and VAP-B, respectively) and at a ground station. Using 1 sec resolution vector magnetic field data, we measured the X-component of the pulsation from the Abu Simbel ground station (L = 1.07, LT = UT +2 hr, where LT represents local time) in Egypt. At the time of the Pi2 event, Abu Simbel and VAP-A (L = 3.3) were in the morning sector (07:38 LT and 07:59 MLT, respectively, where MLT represents magnetic local time), and VAP-B was in the postmidnight sector (04:18 MLT and L = 5.7). VAP-A and VAP-B observed oscillations in the compressional magnetic field component (Bz), which were in close agreement with the X-component measurements of the Pi2 pulsation that were made at Abu Simbel. The oscillations observed by the satellites and on the ground were in phase. Thus, we concluded that the observed morningside Pi2 pulsation was caused by the cavity resonance mode rather than by ionospheric current systems.

Assisted Magnetic Resonance Imaging Diagnosis for Alzheimer's Disease Based on Kernel Principal Component Analysis and Supervised Classification Schemes

  • Wang, Yu;Zhou, Wen;Yu, Chongchong;Su, Weijun
    • Journal of Information Processing Systems
    • /
    • v.17 no.1
    • /
    • pp.178-190
    • /
    • 2021
  • Alzheimer's disease (AD) is an insidious and degenerative neurological disease. It is a new topic for AD patients to use magnetic resonance imaging (MRI) and computer technology and is gradually explored at present. Preprocessing and correlation analysis on MRI data are firstly made in this paper. Then kernel principal component analysis (KPCA) is used to extract features of brain gray matter images. Finally supervised classification schemes such as AdaBoost algorithm and support vector machine algorithm are used to classify the above features. Experimental results by means of AD program Alzheimer's Disease Neuroimaging Initiative (ADNI) database which contains brain structural MRI (sMRI) of 116 AD patients, 116 patients with mild cognitive impairment, and 117 normal controls show that the proposed method can effectively assist the diagnosis and analysis of AD. Compared with principal component analysis (PCA) method, all classification results on KPCA are improved by 2%-6% among which the best result can reach 84%. It indicates that KPCA algorithm for feature extraction is more abundant and complete than PCA.

Effect of in-Plane Magnetic Field on Rashba Spin-Orbit Interaction

  • Choi, Won Young;Kwon, Jae Hyun;Chang, Joonyeon;Han, Suk Hee;Koo, Hyun Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.394-394
    • /
    • 2013
  • The spin-orbit interaction has received great attention in the field of spintronics, because of its property and applicability. For instance, the spin-orbit interaction induces spin precession which is the key element of spin transistor proposed by Datta and Das, since frequency of precession can be controlled by electric field. The spin-orbit interaction is classified according to its origin, Dresselhaus and Rashba spin-orbit interaction. In particular, the Rashba spin-orbit interaction is induced by inversion asymmetry of quantum well structure and the slope of conduction band represents the strength of Rashba spin-orbit interaction. The strength of spin-orbit interaction is experimentally obtained from the Shubnikov de Hass (SdH) oscillation. The SdH oscillation is resistance change of channel for perpendicular magnetic field as a result of Zeeman spin splitting of Landau level, quantization of cyclotron motion by applied magnetic field. The frequency of oscillation is different for spin up and down due to the Rashba spin-orbit interaction. Consequently, the SdH oscillation shows the beat patterns. In many research studies, the spin-orbit interaction was treated as a tool for electrical manipulation of spin. On the other hands, it can be considered that the Rashba field, effective magnetic field induced by Rashba effect, may interact with external magnetic field. In order to investigate this issue, we utilized InAs quantum well layer, sandwiched by InGaAs/InAlAs as cladding layer. Then, the SdH oscillation was observed with tilted magnetic field in y-z plane. The y-component (longitudinal term) of applied magnetic field will interact with the Rashba field and the z-component (perpendicular term) will induce the Zeeman effect. As a result, the strength of spin-orbit interaction was increased (decreased), when applied magnetic field is parallel (anti-parallel) to the Rashba field. We found a possibility to control the spin precession with magnetic field.

  • PDF

Magnetotail responses to sudden and quasi-periodic solar wind variations

  • Kim, Khan-Hyuk;Lee, Dong-Hun
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.33-33
    • /
    • 2003
  • A clear bipolar (negative/positive) signature in the Ey component was observed by the Cluster satellite in the magnetotail during a sudden impulse (si) on October 11, 2001 (day 284). During the interval of the negative perturbation in Ey, the magnetic field strength in Bx, a dominant magnetic field component, was nearly constant. However, the amplitude of Bx was strongly enhanced during the positive Ey perturbation. We suggest that the observed E and B field variations are due to outward/inward plasma motions, associated with expanded and then compressed magnetopause variations. We also observed quasi-periodic geomagnetic perturbations in the Pc5 band (∼1-6 mHz) at the low-latitude ground station Kakioka (L = 1.25) following the si event. They were highly correlated with the magnetic field perturbations at Cluster in the magnetotail (Xgse = ∼12 Re). We show that the source of these perturbations is the quasi-periodic solar wind pressure variations moving tailward.

  • PDF

A Study on the Magnetic Properties of Medicinal Ointments by Mossbauer Spectroscopy. (뫼스바우어 분광법에 의한 의약용 연고제의 자기적 특성 연구)

  • 도태성;김응찬;남효덕;최세곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.327-330
    • /
    • 1998
  • The stability of the properties of magnetite particles in novel medicinal magnetic ointments of multipurpose application was examined by Mossbauer spectroscopy. Comparative analysis of the results obtained by model fitting of $\^$57/Fe nuclei spectra with those known for the system Fe$_3$O$_4$-${\gamma}$-Fe$_2$O$_3$ allowed to identify the phase composition of the particles. This composition, as well as that of the initial pure component in the form of a highly dispersed fraction (∼ 100${\AA}$), differs noticeably from the stoichiometric one. Despite their small sizes, the particles exhibit no superparamagnetism ( in the temperature range from 95 to 300k ). Radiative sterilization of the ointments has no effect on the magnetic component composition.

  • PDF

Tuning of the ferromagnetic transition by impurity doping in Ru$Sr_2$EuCe$Cu_2$$O_z$ (불순물 치환을 통한 Ru$Sr_2$EuCe$Cu_2$$O_z$ 계의 강자성 천이온도의 조절특성)

  • Lee H. K;Kim Y. H;Kwon O. H
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.37-40
    • /
    • 2004
  • We investigated the effects of impurity doping on the electrical transport and magnetic properties of TEX>$(Ru, Sn)(Sr, La)<_2$$EuCeCu_2$$O_{z}$ samples. We found that Sn substitution fur Ru causes a significant decrease of the volume fraction of ferromagnetic phase, as well as a decrease of the temperature where the ferromagnetic component is observed. La substitution for Sr leads to an increase of the magnetic ordering temperature with a moderate change of ferromagnetic component. The experimental results are discussed in conjunction with the structural data, transport properties and a possible change of oxygen content.

  • PDF