• 제목/요약/키워드: Magnetic attachment

검색결과 77건 처리시간 0.025초

FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발 (Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion)

  • 문기욱;김철승;김지원;이재호;권유리;강동원;강곤;김요한;엄광문
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

영구자석바퀴를 이용한 벽면 이동로봇의 설계치침에 의한 이동체 개발 (Development of mobile vehicle designed by the guideline of wall-climbing mobile robot using permanent magnetic wheels)

  • 한승철;이화조;김은찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1676-1681
    • /
    • 2003
  • The attachment of mobile vehicle is necessary for the automated operation on the inclined or vertical walls of steel structures. Since the vehicle requires attaching devices additionally, its overall efficiency can be reduced by the devices. Therefore, external shapes of mobile vehicles have to be researched to give the effective movement on the vertical face. For the design of mobile vehicle, the guideline has been derived from the modeling of wall-climbing, so that the vehicle should have a specific external shape for vertical movement due to the gravitational force. Hence, some adequate arrangement of attaching device to the mobile vehicle has been presented for the effective movement. In the experiments with four permanent magnetic wheels, a plausible result was achieved as a vertical attaching force of 185.2(N), a friction force of 153.8(N) and a curvature radius of 1.4m. The mobile vehicle should be modified according to the proposed design guideline. and then it could be applied to a specific operation as an appropriate external shape. Also, Further research is recommended on an optimal posture and a moving method in a specific application. as the attaching force ortho vehicle can be affected by its posture.

  • PDF

영구 자석 바퀴를 이용한 벽면 이동 로봇의 설계시의 제약 사항들에 대한 연구 (Part 2- 이동체 설계) (Study on the Design Constraints of the Wall-Climbing Mobile Robot Using Permanent Magnetic Wheels (Part 2- Design of Mobile Vehicle))

  • 한승철;이화조;김은찬
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.77-84
    • /
    • 2004
  • The attachment of mobile vehicle is necessary for the automated operation on the inclined or vertical walls of steel structures. Since the vehicle requires attaching devices additionally, its overall efficiency can be reduced by the devices. Therefore, external shapes of mobile vehicles have to be researched to give the effective movement on the vertical face. For the design of mobile vehicle, the guideline has been derived from the modeling of wall-climbing, so that the vehicle should have a specific external shape for vertical movement due to the gravitational force. Hence, some adequate arrangement of attaching device to the mobile vehicle has been presented for the effective movement. In the experiments with four permanent magnetic wheels, a plausible result was achieved as a vertical attaching force of 185.2(N), a friction force of 153.8(N) and a curvature radius of 1.4m. The mobile vehicle should be modified according to the proposed design guideline, and then it could be applied to a specific operation as an appropriate external shape. Also, Further research is recommended on an optimal posture and a moving method in a specific application, as the attaching force of the vehicle can be affected by its posture.

자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구 (A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging)

  • 손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제17권7호
    • /
    • pp.437-442
    • /
    • 2017
  • 최근 자기공명신호를 형성시키지 않는 보상물질을 이용하여 신호강도를 높이려는 연구가 활발히 진행되면서 검사부위에 보상물질을 직접 부착함에 따른 환자감염의 우려가 나타나고 있다. 이에 본 연구에서는 발상의 전환으로 보상물질을 코일에 간접 부착함으로써 기존의 직접 부착방식을 대체할 수 있는지 알아보고자 하였다. 연구방법은 보상물질인 실리콘을 원통형 bar의 형태로 제작하여 8채널 head 코일의 element에 부착한 후, 실리콘 부착 전 후 water phantom의 신호강도를 측정하였다. 영상획득은 3.0T 초전도 자기공명영상장치와 8채널 head 코일을 이용하여 T1, T2강조영상을 획득하였으며, 획득한 영상은 영상측정프로그램을 이용하여 신호강도를 측정한 후, 대응표본T검정을 이용하여 유의한 차이가 있는지 판단하였다. 부착 전 후 신호강도는 T1 강조영상은 3.39%, T2 강조영상은 2.62% 유의하게 증가하였다. 결론적으로 간접 부착방식은 증가율이 낮아 모든 환자를 대상으로 대체하기에는 한계가 있을 수 있지만, filling factor의 증가로 인한 신호강도의 의미있는 상승이 있으므로 당뇨병 등 감염성 질한 우려 환자에 적용 시 유용하리라 판단된다.

Process effects on morphology, electrical and optical properties of a-InGaZnO thin films by Magnetic Field Shielded Sputtering

  • 이동혁;김경덕;홍문표
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.217-217
    • /
    • 2016
  • The amorphous InGaZnO (a-IGZO) is widely accepted as a promising channel material for thin-film transistor (TFT) applications owing to their outstanding electrical properties [1, 2]. However, a-IGZO TFTs have still suffered from their bias instability with illumination [1-4]. Up to now, many researchers have studied the sub-gap density of states (DOS) as the root cause of instability. It is well known that defect states can influence on the performances and stabilities of a-IGZO TFTs. The defects states should be closely related with the deposition condition, including sputtering power, and pressure. Nevertheless, it has not been reported how these defects are created during conventional RF magnetron sputtering. In general, during conventional RF magnetron sputtering process, negative oxygen ions (NOIs) can be generated by electron attachment in oxygen atom near target surface and then accelerated up to few hundreds eV by a self-bias; at this time, the high energy bombardment of NOIs induce defects in oxide thin films. Recently, we have reported that the properties of IGZO thin films are strongly related with effects of NOIs which are generated during the sputtering process [5]. From our previous results, the electrical characteristics and the chemical bonding states of a-IGZO thin films were depended with the bombardment energy of NOIs. And also, we suggest that the deep sub-gap states in a-IGZO as well as thin film properties would be influenced by the bombardment of high energetic NOIs during the sputtering process.In this study, we will introduce our novel technology named as Magnetic Field Shielded Sputtering (MFSS) process to prevent the NOIs bombardment effects and present how much to be improved the properties of a-IGZO thin film by this new deposition method. We deposited a-IGZO thin films by MFSS on SiO2/p-Si and glass substrate at various process conditions, after which we investigated the morphology, optical and electrical properties of the a-IGZO thin films.

  • PDF

토실 활성화된 폴리스티렌 마이크로구체 자성 입자 표면의 화학적 변형에 대한 적외선 연구 (Investigation of chemical modification on tosyl-activated polystyrene microsphere magnetic particle surface by infrared microscopy)

  • 변창규
    • 분석과학
    • /
    • 제29권5호
    • /
    • pp.225-233
    • /
    • 2016
  • 입자 표면에 고분자를 화학적으로 접목하는 것은 수용성 액체 이상 시스템(ATPS)과 같이 분리된 액체 층에서 마이크로/나노입자를 선택적으로 분배시키는데 중요한 구실을 한다. 본 연구에서는 덱스트란, 폴리에틸렌 글리콜, 알부민을 화학적으로 폴리스티렌 자성 마이크로입자 표면에 화학적으로 부착시켰다. 분배 현상을 역전시킬 수 있는 긴 고분자 사슬의 부착은 일차 아민 작용기를 가진 다양한 고분자를 p-톨루엔술폰산(토실)기를 부착시킨 폴리스티렌 자성 마이크로입자와의 SN2 치환에 의해 간단히 수행될 수 있었다. 이 후 적외선 현미경을 사용하여 마이크로입자의 표면 변화의 유무를 검사하였다. 반응 후 입자들은 세 가지 폴리머 모두 N-H 신축 진동 피크를 보였으며 대부분의 주요 피크들의 위치는 반응 전후에 유사하였으나 지문 영역에서 구별 가능한 차이를 보였다.

Non-Dura Based Intaspinal Clear Cell Meningioma

  • Ko, Jun-Kyeung;Choi, Byung-Kwan;Cho, Won-Ho;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권1호
    • /
    • pp.71-74
    • /
    • 2011
  • A 34-year-old female patient was presented with leg and hip pain for 6 months as well as voiding difficulty for 1 year. Magnetic resonance imaging revealed a well-demarcated mass lesion at L2-3. The mass was hypo-intense on T1- and T2-weighted images with homogeneous gadolinium enhancement. Surgery was performed with the presumptive diagnosis of intradural extramedullary meningioma. Complete tumor removal was possible due to lack of dural adhesion of the tumor. Histologic diagnosis was clear cell meningioma, a rare and newly included World Health Organization classification of meningioma usually affecting younger patients. During postoperative 2 years, the patient has shown no evidence of recurrence. We report a rare case of cauda equina clear cell meningioma without any dural attachment.

Primary Intradural Extramedullary Myxopapillary Ependymoma

  • Kim, Saeng-Yeob;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권5호
    • /
    • pp.382-384
    • /
    • 2006
  • We report a rare case of primary intradural extramedullary myxopapillary ependymoma of the spinal cord. A 45-year-old woman was admitted to the author's institution with a history of progressive paraparesis[grade IV/IV] with back pain. Neurologic examination revealed decreased sensation below T12 sensory dermatome level. Magnetic resonance imaging[MRI] revealed an intermediate enhanced intradural extramedullary tumor extending from T12. Total resection of the tumor was achieved by T12 laminectomy. Intraoperatively, there was no finding of attachment to rootlet and dura. Histopathological examination identified the tumor as a myxopaillary ependymoma. To the best of my knowledge, this is the first reported case of primary intradural extramedullary ependymoma in Korea.

Meningioma in a 20-Month-Old Boy

  • Jung, Yeon-Seong;Song, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권4호
    • /
    • pp.219-221
    • /
    • 2012
  • A 20-month-old boy presented with a intraparenchymal mass in the right frontoparietal area manifesting as complex partial seizure, secondary generalization and left hemiparesis. Magnetic resonance images (MRI) of the brain showed inhomogeneously enhancing mass in the right frontoparietal area which has irregular margin and perilesional edema. Based on the radiological findings, a preoperative diagnosis was an intraaxial tumor, such as pilocytic astrocytoma or dysembryoplastic neuroepithelial tumor. The patient underwent a surgery including frontal craniotomy. The tumor had a partially extreme adherence to the surrounding brain tissue but it showed no dural attachment. Gross-total resection of the tumor was achieved. Postoperative follow-up computed tomography scans showed no residual tumor. The pathological findings confirmed the tumor as a WHO grade I meningioma, transitional type. Nine months after the surgery, follow-up brain MRI showed no recurrence of the tumor, porencephaly in site where the tumor was resected; the patient's symptoms had fully recovered. We report the case of a meningioma in a 20-month-old boy.

Primary Extramedullary Ependymoma of the Cervical Spine : Case Report and Review of the Literature

  • Son, Dong-Wuk;Song, Geun-Sung;Han, In-Ho;Choi, Byung-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.57-59
    • /
    • 2011
  • Intradural extramedullary (IDEM) ependymomas occur very rarely and little has been reported about their clinical characteristics. The authors present a case of a 57-year-old woman with an IDEM ependymoma. She was referred for the evaluation of a 4-month history of increasing neck pain and muscular weakness of the left extremities. Magnetic resonance imaging (MRI) of the cervical spine demonstrated an IDEM tumor with spinal cord compression. At the time of surgery, an encapsulated IDEM tumor without a dural attachment or medullary infiltration was noted, but the tumor capsule adherent to the spinal cord and root was left in place to minimize the risk of neurological sequelae. Histologic examination revealed a benign classic ependymoma. The post-operative course was uneventful and radiotherapy was performed. The patient showed an excellent clinical recovery, with no recurrence after 5 years of follow-up.