• 제목/요약/키워드: Magnetic array

검색결과 285건 처리시간 0.027초

동전기력에 기초한 자기 부상 평면 운송 시스템의 부상 메커니즘에 관한 연구 (A Study on the Levitation Mechanism Based on the Electrodynamic Force for a Maglev Planar Transportation System)

  • 박준혁;백윤수
    • 대한기계학회논문집A
    • /
    • 제30권9호
    • /
    • pp.1025-1033
    • /
    • 2006
  • This paper describes the levitation mechanism using magnetic wheel for a maglev planar transportation system. Rotation of the magnetic wheel where the permanent magnet array is embedded produces the time varying traveling magnetic flux density and the generated magnetic flux density creates the induced levitation force and drag force with the conductor. Because the net drag force is zero, magnetic wheel can only generate the levitation force. Thus, it always guarantees the stability in levitation direction and it does not disturb other directional motion. In this paper, levitation principle of the magnetic wheel is analyzed using distributed field approach and dynamic characteristics of the levitation in the magnetic wheel system are estimated. The feasibility of the proposed levitation mechanism is verified through the several experimental works.

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

Halbach 배열을 가진 SPMPM의 특성해석에 관한 연구 (Characteristics Analysis of Synchronous Permanent Magnet Planar Motor with Halbach Array)

  • 주건배;황예;이동엽;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권9호
    • /
    • pp.465-471
    • /
    • 2006
  • In this paper, a synchronous permanent magnet planar motor (SPMPM) with Halbach array is proposed. First, we give the equations of the magnetic scalar potential and a series of boundary conditions. The magnetization and flux density distribution of Halbach array are obtained by analytical method; then, the characteristics of this SPMPM such as inductance, back-EMF, and thrust are evaluated. At last, the experiment results are used to verify the analysis property of this SPMPM. By comparison, it can be concluded that the analysis of SPMPM with Halbach magnet array is credible and feasible.

센서 바이어스를 보상하는 칼만필터 기반의 예인 선배열 센서 형상 추정 기법 (Towed Array Shape Estimation based on Kalman Filter Compensating the Sensor Bias)

  • 김근환;최수진;류창수;류영우;이균경
    • 한국군사과학기술학회지
    • /
    • 제19권2호
    • /
    • pp.155-162
    • /
    • 2016
  • TASS(Towed Array Sonar System) is a sonar system which tows the sensor array behind a platform. Array shape is generally assumed to be a straight line. But the array shape is often distorted by oceanic current or platform maneuvering which causes the performance loss of signal processing method like beamforming. So array shape estimation methods are needed. Typically the method based on Kalman filter using heading sensor is used. In practice, the measurement is corrupted by biases which are caused by rotation of the tow cable, varying magnetic fields and slowly varying stresses in the mechanical construction. Although they can't be calibrated but can be estimated. In this paper, we suggest the array shape estimation method based on Kalman filter compensating the sensor biases.

Babinet-principle-inspired Metasurfaces for Resonant Enhancement of Local Magnetic Fields

  • Seojoo, Lee;Ji-Hun, Kang
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.97-103
    • /
    • 2023
  • In this paper, we propose Babinet-principle-inspired metasurfaces for strong resonant enhancement of local magnetic fields. The metasurfaces are designed as complementary structures of original metasurfaces supporting the local enhancement of electric fields. We show numerically that the complementary structures can support spoof magnetic surface plasmons that induce strong local magnetic fields without sacrificing the deep sub-wavelength-thick nature of the metasurface. By introducing a periodic array of metallic rods in the proximity of the metasurfaces, we demonstrate that a resonant enhancement of the local magnetic fields, more than 80 times the amplitude of an incident magnetic field, can emerge from a resonance of the spoof magnetic surface plasmons.

어레이 IrMn 스핀밸브 소자의 자기저항특성 연구 (Magnetoresistive Properties of Array IrMn Spin Valves Devices)

  • 안명천;최상대;주호완;김기왕;황도근;이장로;이상석
    • 한국자기학회지
    • /
    • 제17권4호
    • /
    • pp.156-161
    • /
    • 2007
  • 어레이(away) 자성센서 개발을 위해 고진공 스퍼터링 증착장비를 이용하여 스펙큘러형(specular type) Glass/Ta(5)/NiFe(7)/IrMn(10)/NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; CMR-SV)박막을 제작하였다. 다층박막 시료를 $20{\times}80{\mu}m^2$의 미세 활성영역을 가진 15개 어레이를 $8{\times}8mm^2$ 영역 내에 최적화한 제작 조건으로 광 리소그래피 패터닝 하였다. Cu를 증착하여 만든 2단자 전극법으로 측정한 자성특성은 15개 모든 소자들이 균일한 자기저항특성을 나타내었고, 5 Oe 근방에서 가장 민감한 자기저항비 자장민감도와 출력전압들은 각각 0.5%/Oe, ${\triangle}$V: 3.9 mV이었다. 형상자기이방성이 적용된 상부 자유층 $CoFe/O_2/NiFe$층은 하부 고정 자성층 $IrMn/NiFe/O_2/CoFe$층 자화 용이축과 직교하였다. 측정시 인가전류 값을 각각 1 mA에서 10 mA까지 인가하였을 때 출력 작동 전압 값은 균일하게 증가하였으며, 자장감응도도 거의 일정하여 미세 외부자장에 민감한 나노자성소자로서 좋은 특성을 띠었다.

7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선 (Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T)

  • 김경남;김영보;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.103-114
    • /
    • 2012
  • 목적: 7T 악관절 자기공명상의 개선을 위해 제안된 4 채널 스파이럴 코일과 그를 구동시키기 위한 회로는 자기장의 분포, 송신 전용필드, 신호 대 잡음 비, 그리고 악관절 영상에 대하여 일반적인 단일 루프 형태의 코일과 비교되었다. 대상과 방법: 단일 채널 그리고 4 채널 스파이럴 코일은 단일 루프 형태의 코일에 대해 전자기장 시뮬레이션으로 자기장의 분포 및 송신 전용 필드에 대해서 비교 되었고, 7T에서 이를 평가하고자 송신전용 필드와 더불어 자기장의 분포 역시 비교 평가되었다. 결과: 전자기장 시뮬레이션의 결과와 7T 자기공명영상에서 4 채널 스파이럴 코일은 기존에 사용되는 일반적인 구조인 단일 루프 코일에 비해 상대적으로 우수한 자기장의 분포 및 송신 전용 필드를 보였다. 결론: 7T에서는 코일의 구조에 비해 상대적으로 영상화되는 물질의 특성에 더욱더 의존적이나, 각각의 코일은 다른 필드 분포를 나타냄으로써 최적화된 코일은 악관절 영상과 같은 특정 용도로 사용될 수 있음을 확인하였다.

General Analytical Method for Magnetic Field Analysis of Halbach Magnet Arrays Based on Magnetic Scalar Potential

  • Jin, Ping;Yuan, Yue;Lin, Heyun;Fang, Shuhua;Ho, S.L.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.95-104
    • /
    • 2013
  • This paper presents a general analytical method for predicting the magnetic fields of different Halbach magnet arrays with or without back iron mounted on slotless permanent magnet (PM) linear machines. By using Fourier decomposition, the magnetization components of four typical Halbach magnet arrays are determined. By applying special synthetic boundary conditions on the PM surfaces, the expressions of their magnetic field distributions are derived based on the magnetic scalar potential (MSP), which are simpler than those based on the magnetic vector potential (MVP). The correctness of the method is validated by finite element analysis. The harmonics of airgap flux density waveforms of these Halbach magnet arrays with or without back iron are also compared and optimized.

자기공명영상검사 시 Array coil에서 element를 선택하여 신호를 수집하는 기법의 유용성 (Usefulness of the Technique of Collecting Signals by Selecting Elements from RF Receive Phase Array Coil in Magnetic Resonance Imaging)

  • 최관우;손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제18권6호
    • /
    • pp.461-466
    • /
    • 2018
  • 본 연구는 자기공명영상에서 array coil을 이용한 부분영역의 영상화 시 SNR을 증가시킬 수 있는 방안으로 element를 선택하여 신호를 수집하는 기법의 유용성에 대해 알아보고자 하였다. 연구방법은 array coil에 두 개의 원통형 fluid phantom을 나란히 위치시킨 다음, 부분영역인 한 개의 fluid phantom 영상화 시 element 전체를 사용하여 신호를 수집하는 경우와 선택한 경우로 나누어 SNR을 비교하였다. 연구결과, T1, T2 강조영상 모두 element를 선택하여 신호를 수집하는 경우가 전체를 사용한 경우보다 T1강조영상은 5.49%, T2강조영상은 14.64% 유의하게 증가하였다. 결론적으로 array coil을 이용한 부분영역의 영상화 시 element를 선택하여 신호를 수집하면 손쉽게 SNR을 증가시킬 수 있으리라 판단된다.