Comparison Analysis of Donor Liver Volumes Estimated with 3D Magnetic Resonance and 3D Computed Tomography Image Data

  • Kim, Myeong-Seong;Park, Kyeong-Seok;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.261-265
    • /
    • 2014
  • Three-dimensional computed tomography is an effective tool to estimate the liver volume of living donors for the live liver transplantation. When additional operation is required, magnetic resonance imaging is conducted to determine the safety of the donor. This study compared the accuracy of magnetic resonance imaging and computed tomography in estimating 3D liver volume of 23 male and 7 female donors who underwent both magnetic resonance imaging and computed tomography tests before the transplantation. The analysis was conducted to see whether the liver's estimated total volumes and the left lobe volumes obtained from 3D-magnetic resonance imaging and 3D-computed tomography were identical. Volumes of the right lobe estimated with 3D-magnetic resonance imaging and 3D-computed tomography were compared with the actual volume of the right lobe harvested in the operating room because the volume of the right lobe is an important determinant in the safety of the donor. The total volume of the liver estimated from 3D-magnetic resonance imaging and 3D-computed tomography differed (1238.1904 units and 1402.364 units respectively). The left lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography also differed (450.530 units and 554.490 units, respectively). The right lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography were 787.660 units and 847.545 units, respectively, while the actual average right lobe volume of the harvested liver was 678.636 units. 3D-computed tomography has been widely used to estimate the right lobe volume of the donors' liver. However, 3D-magnetic resonance imaging was also very effective in estimating the volume of the liver. Thus, 3D-magnetic resonance imaging is also expected to become an important tool in determining the safety of the donors before transplantation.

Design and Development of the Magnetic Tomography System Using Two Poles Perpendicular Magnetic Field (2극 수직자계를 이용한 Magnetic Tomograpy의 설계와 제작)

  • 박은식;박관수
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.61-67
    • /
    • 2003
  • This paper describes a development of magnetic tomography system using two poles perpendicular magnetic field. In the system, the relative permeabilities of the object are detected by Hall sensors located along with tube circumference. The signals according to the size and position of the object could be separated in case the relative permeability of the object are over 10. Moreover, the size and location of the object could be determined in real time.

Probing galactic and intergalactic magnetic fields using Faraday tomography (optionally title in Korean in parentheses)

  • Ideguchi, Shinsuke;Takahashi, Keitaro;Akahori, Takuya;Ryu, Dongsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.31.1-31.1
    • /
    • 2015
  • For probing magnetic fields in the universe, rotation measure (RM) have been often used. RM allows us to obtain the information of integrated (or averaged) magnetic fields along a line of sight (LOS). On the other hand, the new technique so-called Faraday tomography will be used in practical in the near future thanks to the wide-band polarimetry by Square kilometre Array and/or its precursors. The technique allows us to obtain so-called Faraday dispersion function (FDF). FDF is the distribution function of magnetic fields and polarized sources along a LOS. Because of this fact, it is expected that the studies of magnetic fields associated with various astronomical objects will progress dramatically. Since FDF also includes information of cosmic-rays and thermal electrons, the investigation of FDF may advance the studies of dynamics of external galaxies and/or the star formation activities. We have studied the potentials of Faraday tomography such as a tool to probe the intergalactic magnetic field associated with filaments of galaxies in the large scale structure. We have also studied the realistic FDFs of galaxies for understanding global magnetic field, cosmic-ray and thermal electrons of external galaxies. In the talk, we briefly introduce the Faraday tomography technique and report the results related to the Faraday tomography.

  • PDF

Design and Fabrication of the Magnetic Tomography by using Hall Sensors (Hall Sensor를 이용한 Magnetic Tomography 설계와 제작)

  • Park, Eun-Sik;Park, Gwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.87-91
    • /
    • 2002
  • 본 연구는 탐지 대상물체의 형상인식 이 가능한 비접촉, 원격 탐지장치의 개발에 관한 것이다. 형체인식용 비접촉 시스템은 주로 Magneto-Impedance법과 Magneto-Inductance법이 있 으며, Magneto- Inductance법은 왜곡이 적고, 인체나 탐지대상물체에 손상을 가져오지 않는다. 본 연구에서는 2극으로 디자인 된 Magnetic Tomography System을 이용하여 물체의 위치에 따른 투자율 변화량을 계산 및 실측하였다.

  • PDF

Foramen transversarium enlargement caused by vertebral artery tortuosity: Diagnosis with cone-beam computed tomography and magnetic resonance angiography

  • Omami, Galal
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.329-332
    • /
    • 2021
  • A markedly enlarged foramen transversarium was discovered incidentally on a cone-beam computed tomography scan of a 72-year-old male patient who was referred for dental implant placement. Further evaluation with magnetic resonance angiography revealed that the foramen enlargement was caused by a tortuosity in the course of the vertebral artery. This case report highlights the importance of recognizing significant incidental findings on diagnostic images and the potential need for additional imaging as part of the complete interpretative process.

MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY

  • Kwon, Oh-In;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • Communications of the Korean Mathematical Society
    • /
    • v.16 no.3
    • /
    • pp.519-541
    • /
    • 2001
  • Magnetic Resonance Electrical Impedance Tomography(MREIT) is a new medical imaging technique for the cross-sectional conductivity distribution of a human body using both EIT(Electrical Impedance Tomography) and MRI(Magnetic Resonance Imaging) system. MREIT system was designed to enhance EIT imaging system which has inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. MREIT utilizes a recent CDI (Current Density Imaging) technique of measuring the internal current density by means of MRI technique. In this paper, a mathematical modeling for MREIT and image reconstruction method called the alternating J-substitution algorithm are presented. Computer simulations show that the alternating J-substitution algorithm provides accurate high-resolution conductivity images.

  • PDF

Detection of Size and Position in Magnetic Inductance Tomography System (Magnetic Inductance Tomography System을 이용한 대상물체의 위치와 크기 판정)

  • Seo, Kang;Park, Gwan-Soo;Park, Eun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1074-1076
    • /
    • 2005
  • Magnetic Inductance Tomography System은 비투자율이 공기보다 큰 대상물체를 외부에서 자기장을 인가하여 자기장의 변화를 자기센서로 측정하여 대상물체의 형상, 위치, 비투자율을 측정하고 판단하는 시스템이다. Magnetic Inductance Tomog-raphy System은 비투자율이 공기보다 큰 대상물체를 외부에서 자기장을 인가하여 자기장의 변화를 자기센서로 측정하여 대상물체의 형상, 위치, 비투자율을 측정하고 판단하는 시스템이다. Magnetic Inductance To-mography System은 대상물체의 위치, 모양, 크기에 따라 자기장의 변화가 달라게 된다. 대상물체를 실시간으로 측정하기 위하여 Magnetic Inductance To-mography System을 자기장 발생부와 신호변환부, 모니터링 부로 구분하여 구축하였다. 또한 대상물체를 위치를 이동시키거나 크기를 변경하여 대상물체의 신호를 해석, 측정하였다.

  • PDF

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Metastasis of Rhabdomyosarcoma to the Male Breast: a Case Report with Magnetic Resonance Imaging Findings

  • Kim, Myeongjong;Kang, Bong Joo;Park, Ga Eun;Kim, Sung Hun;Lee, Jeongmin;Lee, Ahwon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.75-80
    • /
    • 2019
  • Metastasis of rhabdomysarcoma to the breast is a very rare manifestation in adult males. Herein, we report a case of metastasis from embryonal rhabdomyosarcoma in the left hypothenar muscle that presented as a breast mass in a 38-year-old man, who four months later expired because of multiple bone metastases related to pancytopenia. We describe the various imaging findings, including mammograms, ultrasonography, computerized tomography (CT), positron emission tomography-computed tomography (PET-CT), and magnetic resonance imaging (MRI) of this rare disease. The various imaging findings of this lesion could be helpful for future diagnosis of male breast lesions.