• Title/Summary/Keyword: Magnetic Shield

Search Result 103, Processing Time 0.032 seconds

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

Reduction Effects of Electromagnetic fields in Conductor Shields (도체차폐판의 전자계 감소효과)

  • Kang, Dae-Ha;Kim, Won-Hee;Lee, Yuong-Sik;Son, Jung-Dae;Park, Yoon-Dong;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1595_1596
    • /
    • 2009
  • In this study reduction effects of magnetic field were analyzed using multi-conductor method in analysis of shield. The method can be effective in the analysis because of reducing the amount of allocated memory and computing time. And also the method can be applicable to analysis of the induced current distributions and skin effect in shield. The results of the analysis are presented.

  • PDF

Analysis of Current Distribution of Multi-Layer HTSC Power Cable dut to Pitch length and winding direction (피치길이와 결선방향에 따른 다층 고온초전도 전력케이블의 전류분류 분석)

  • Lee Jong-Hwa;Lim Sung-Hun;Ko Seokcheol;Park Chung-Ryul;Han Byoung-Sung;Hwang Si Dole
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1133-1135
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of important parameters in high-temperature superconducting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and ac loss. In this paper, the transport current and magnetic field distributions at conducting layers were investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer. The transport current distribution due to the pitch length and winding direction was improved in case of HTSC power cable with shield layer.

  • PDF

Magnetic shield capability according to structure and material property of shield material in EML coating system (차폐재질 및 차폐구조에 따른 EML 코일 주변 자기장 차폐성능평가)

  • Song, Myeong-Gon;Jeong, Yong-Hwa
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.263-263
    • /
    • 2012
  • EML coating system은 코팅물질에 적절한 열을 가하기 위하여 상당히 높은 수준의 자기장을 이용한다. 이러한 이유로 인하여 EML 코일 주변에 자기장 차폐를 하지 않을 경우 주변의 금속성 물질에 전자기 유도 현상에 의하여 높은 수준의 와전류가 발생하여 결과적으로 열적인 손실을 발생하게 된다. 이러한 열적인 손실은 전체 시스템읠 효율 뿐 만 아니라 시스템의 안정적인 운전에도 좋지 않은 영향을 주게 된다. 이러한 영향을 방지하기 위하여 EML coil 주변은 자기 차폐를 하게 된다. 본 논문에서는 자기장 차폐용도로 사용하게 되는 자기차폐용 물질의 종류 및 구조에 따른 자기차폐성능 및 각 자기차폐물질에서의 발열을 전자기 해석을 통하여 도출 하였다.

  • PDF

The Study on a Fixing-clip of a Shield Can Shielding Electromagnetic wave (전자파 차단을 위한 �Q드캔용 고정 클립 개발에 관한 연구)

  • Park, Tai-Heoun;Park, Man-Gyu;Park, Sang-Heup;Kim, Key-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.554-560
    • /
    • 2013
  • This study proposes an structure that fixes the shielding device to two parts of the board by its two arranged clips. Said structure evenly distributes its loading/unloading load of the board and maintains the flatness of soldering area of the board. The structure of this study comprises a base part fixed to a printed circuit board and a clip part fixing a side wall of a shield can to the board, wherein the clip part is constituted with two clips fixable to two part of the shield can. Also, the structure of this study comprises a dented groove in order to easily solder the base part of clips and the printed circuit board. A mechanism is established and a design parameter was determined by a structure analysis and a vibration mode analysis. A single purpose machine for the production of the product was developed, the final workpiece was produced and the measuring-data and the computered-data was compared and reviewed.

A Study on the Radiating Source of Electro-magnetic Waves in the Cabin of Automobile (자동차 실내의 전자파 복사원에 관한 연구)

  • Choe, Gwang-Je
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.107-114
    • /
    • 2006
  • This paper investigates the radiating source of electro-magnetic waves in the cabin of automobile with spark ignition engine. Front seats are very close to the engine room where electro-magnetic waves are expected to be radiating. But front seat area is believed to be a blind zone, which is not affected by radiating electro-magnetic waves, because a bulk board and floor board shield the front seat area. The level and frequency spectrum of electro-magnetic waves are measured at the passenger seat and the engine room. The measured frequency range is $145{\sim}365MHz$. As a results, the level of the electro-magnetic waves of automatic transmission vehicle is greater than -82dBm. The shapes of frequency spectrum of both engine room and passenger seat are look alike. But the level of electro-magnetic waves of manual transmission vehicle is less than -82dBm and the shapes of frequency spectrum of engine room and passenger seat are different to each other. From these results, we can say that any mal-function caused by electro-magnetic waves in the automobile cabin are only possible for automatic transmission vehicle. Also, it is believed that the radiating source of electro-magnetic waves is inside the vehicle. Thus, based on the transmission line theory, this paper presumably concludes that the cables which connect all the components inside a automatic transmission vehicle must be a radiating source of electro-magnetic waves in the cabin.

Study on the Magnetic Shield Effect of Carbon-based Materials at Extremely Low Frequency (탄소계 소재를 이용한 극저주파 영역에서의 자기 차폐효과 연구)

  • Oh, Seong Moon;Kang, Dong Su;Lee, Sang Min;Baek, Un Gyeong;Roh, Jae Seung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • To examine the magnetic shielding effect for carbon-based materials at extremely low frequencies (60 Hz), two types of carbon black (Super-P and Denka Black) and a natural graphite (HC-198) were mixed into organic binder at 10 wt.% to produce a coating solution, and a powder coating with varying thickness was applied on an aluminum disk measuring 88 mm in radius. A device was developed to measure the sheielding effect at extremely low frequencies. A closed circuit was achieved by connecting a transformer and a resistor. The applied voltage was fixed at 65 V, and the magnetic field was measured to being the range of 4.95~5.10 mG. Depending on the thickness of the coating layer, the magnetic field showed a decreasing trend. The maximum decrease in the magnetic field of 38.3% was measured when natural graphite was coated with specimens averaging $455{\mu}m$. This study confirmed that carbon-based materials enable magnetic shielding at extremely low frequencies, and that the magnetic shielding effect can be enhanced by varying the coating thickness.

Investigation of shielding effects of 60Hz ELF magnetic fields on shielding material property (차폐재의 재료특성에 따른 60Hz ELF 자계차폐 효과분석)

  • Min, Suk-Won;Song, Ki-Hyun;Myung, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1960-1962
    • /
    • 2004
  • In this paper, we have studied shielding characteristics of high conductivity or high permeability materials on ELF magnetic fields generated from single or three phase AC line. Perm alloy has been selected as high permeability material and copper as high conductivity material. Four-plate shield (square section) was considered as a shielding shape. We found copper showed stable shielding effects more than perm alloy.

  • PDF

A Study of a Conduction Cooling System of a HTS SMES System (고온초전도체 SMES 장치의 전도냉각시스템 연구)

  • Koh, Deuk-Yong;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.328-332
    • /
    • 2007
  • A superconducting magnetic energy storage (SMES) system has shorter response time and longer life time, and is more economical, and environment-friendly than other uninterruptible power supply (UPS). A conduction cooling system is well answer for the high temperature superconductor (HTS) SMES system. Because the conduction cooling system is simple, light and small structure. The purpose of this paper is to design and verify the effective conduction cooling system for the HTS SMES system. The analysis of heat loads in cryostat is performed. Thermal shield heat loads, temperatures of HTS coil surface and conduction Cu plate are estimated and measured.

E.M.F Characteristic of Superconducting Synchronous Generator according to Design Parameter (설계변수 변화에 따른 초전도 동기 발전기의 유기기전력 특성)

  • Jo, Young-Sik;Hong, Jung-Pyo;Lee, Ju;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.65-68
    • /
    • 1999
  • The major deisng parameters that are considered in this paper are: 1) EMF according to width of field coil. 2) EMF according to magnetic shield length. Because of superconducting generator (SG) is actually and air cored machine with its rotor iron and stator iron teeth having been removed. In this case, the desing of the SG must be based on the 3D analysis of the magnetic field. This study presents an effective armature winding type with 3D FEM(Finite Element Method), and compares analyzed and measured results.

  • PDF