• 제목/요약/키워드: Magnetic Object

검색결과 219건 처리시간 0.027초

Synthesis of Magnetic Sonophotocatalyst and its Enhanced Biodegradability of Organophosphate Pesticide

  • Lirong, Meng;Jianjun, Shi;Ming, Zhao;Jie, He
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3521-3526
    • /
    • 2014
  • A magnetic sonophotocatalyst $Fe_3O_4@SiO_2@TiO_2$ is synthesized for the enhanced biodegradability of organophosphate pesticide. The as-prepared catalysts were characterized using different techniques, such as X-ray diffraction (XRD) and transmission electron microscopy (TEM). The radial sonophotocatalytic activity of $Fe_3O_4@SiO_2@TiO_2$ nanocomposite was investigated, in which commercial dichlorvos (DDVP) was chosen as an object. The degradation efficiency was evaluated in terms of chemical oxygen demand (COD) and enhancement of biodegradability. The effect of different factors, such as reaction time, pH, the added amount of catalyst on $COD_{Cr}$ removal efficiency were investigated. The average $COD_{Cr}$ removal efficiency reached 63.13% after 240 min in 12 L sonophotocatalytic reactor (catalyst $0.2gL^{-1}$, pH 7.3). The synergistic effect occurs in the combined sonolysis and photocatalysis which is proved by the significant improvement in $COD_{Cr}$ removal efficiency compared with that of solo photocatalysis. Under this experimental condition, the $BOD_5/COD_{Cr}$ ratio rose from 0.131 to 0.411, showing a remarkable improvement in biodegradability. These results showed that sonophotocatalysis may be applied as pre-treatment of pesticide wastewater, and then for biological treatment. The synthesized magnetic nanocomposite had good photocatalytic performance and stability, as when it was used for the fifth time, the $COD_{Cr}$ removal efficiency was still about 62.38%.

다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가 (Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease)

  • 홍인기;박민지;강성현;이영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

PEC 또는 PMC 영역을 포함하는 불균일 임피던스 매질의 산란 해석을 위한 수정된 SDIE MLFMM 방법 (Modified SDIE MLFMM Method for Inhomogeneous Impedance Material Containing PEC or PMC Region)

  • 이현수;고일석;유지희
    • 한국전자파학회논문지
    • /
    • 제29권10호
    • /
    • pp.805-810
    • /
    • 2018
  • 산란파 감소 등의 목적으로 PEC 상에 코팅된 매질은 임피던스 경계조건을 사용하여 효과적으로 모델링되며, Yan이 제안한 SDIE 방법을 이용하여 임피던스 경계조건 MLFMM 방법을 쉽게 구현할 수 있다. SDIE MLFMM 방법은 매질의 임피던스가 불균일한 경우에도 적용될 수 있으나, PEC 또는 PMC 영역을 포함할 경우에는 결과가 부정확해질 수 있다. 본 논문에서는 Yan의 SDIE MLFMM 방법을 변형하여 PEC 또는 PMC 영역을 포함하는 불균일 임피던스 매질을 효율적으로 해석할 수 있는 방법을 제안하고, 그 정확도를 시뮬레이션으로 검증한다.

자기 벡터 포텐셜 해석을 이용한 금속 검출기 코일 헤드의 검출 성능 최적화 (Optimization of the Coil Head of Metal Detectors Using a Magnetic Vector Potential Approach)

  • 오준석;은창수
    • 전자공학회논문지SC
    • /
    • 제46권5호
    • /
    • pp.38-43
    • /
    • 2009
  • 본 논문에서는 자기 벡터 포텐셜 해석을 통해 3-코일 구조를 갖는 금속 검출기 헤드가 수신 코일에 미치는 유도 전압을 구하고, 금속 물체의 특성이 송신 코일의 임피던스에 미치는 영향을 유도하였다. 이러한 해석을 통하여 최적의 검출 성능을 위한 송신 코일과 수신 코일 간의 거리를 구하였고, 최대 유도 전압을 출력하는 금속의 위치를 유도하였다. 또한 기존의 수식과 비교하여 본 논문의 자기 벡터 포텐셜 해석에 대한 타당성을 입증하였다.

3.0 T MRI를 위한 Parallel-Transmission RF 코일 구조의 비교와 최적화 (Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI)

  • 오창현;이흥규;류연철;현정호;최혁진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.61-63
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics and relatively high Larmor frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil element structure and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of 25 cm ${\times}$ 8 cm loop structure with 12 channels for a 3.0 T body coil, the 73% field non-uniformity without optimization was reduced to about 26% after optimization of driving patterns. The experimental as well as simulation results show the utility of the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

  • PDF

클러치 동적 토크 계측에 관한 연구 (A Study on Measuring Clutch Dynamic Torque)

  • 이성구;김동영;허만대
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.65-70
    • /
    • 2012
  • Torque fluctuation of engine generate gear rattle noise of transmission and many researches have been studied to decrease rattle noise by adjusting clutch damper system. So design optimization of clutch system is very important to decrease rattle noise and need knowing clutch dynamic torque at real vehicle driving condition. This makes it possible to measure clutch dynamic torque by using a small-size magnetic sensor. We install a small-size magnetic sensor on the input shaft of the transmission and measure the relative angular displacement between clutch hub and disc plate. We can obtain the clutch torque correspond to the angular displacement in the clutch torsional characteristics test. The object of this research is to measure clutch dynamic torque on real vehicle condition. Therefore, Clutch dynamic torque is very useful for investigating operating range of clutch according to engine torque and predicting the damping performance of torsional vibration on the powertrain.

Intergalactic Magnetic Field and Arrival Direction of Ultra-High-Energy Iron Nuclei

  • 류동수;강혜성
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.78.2-78.2
    • /
    • 2012
  • We have studied how the intergalactic magnetic field (IGMF) affects the propagation of super-GZK iron nuclei that originate from extragalactic sources within the local GZK sphere. Toward this end, we set up hypothetical sources of ultra-high-energy cosmic-rays (UHECRs), virtual observers, and the magnetized cosmic web in a model universe constructed from cosmological structure formation simulations. We then arranged a set of reference objects at high density region to represent astronomical objects formed in the large scale structure (LSS). With our model IGMF, the paths of UHE iron nuclei are deflected on average by about 70 degrees, which might indicate a nearly isotropic distribution of arrival directions. However, the separation angle between the arrival directions and the nearest reference object on the LSS is only ~6 degrees, which is twice the mean distance to the nearest neighbors among the reference objects. This means that the positional correlation of observed UHE iron events with their true sources would be erased by the IGMF, but the correlation with the LSS itself is to be sustained. We discuss implications of our findings for correlations studies of real UHECR events.

  • PDF

객체 중심 계층적 계획을 이용한 뇌경색 환자의 시기별 MRI 정량적 분석에 관한 연구 (MRI Quantification Analysis on Fall in Sick Times of the Cerebral Infarction Patients Using Object-Centered Hierarchical Planning)

  • 하광;전계록;김길중
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.61-68
    • /
    • 2003
  • 본 논문에서는 의학적 진단 및 처치 방법의 결정에 중요한 역할을 하는 뇌경색 환자의 각 시기별 특징을 정량화하기 위해 3 가지 MRI 촬영기법을 이용하여 획득한 영상의 특징과 그들의 상관관계들을 객체중심 계층적계획기법을 이용하여 분석하였다. 3 가지 영상의 비교를 위하여 다항워핑 알고리즘과 어파인 변환기법을 수행하여 영상을 정합하였으며, 정합된 영상을 기반으로 뇌경색 시기별 정량화를 수행하였다. 그리고 각 시기별로 색을 설정하여 수 작업으로 얻어진 데이터를 바탕으로 의사 컬러로 나타내었다. 본 연구에서 구한 뇌경색 시기별 정량화 자료를 바탕으로 구분된 결과와 전문의가 판단한 결과를 비교하였다.

3차원 생물체 가시화 모델 구축장치 개발 및 성능평가 (Development and Evaluation of System for 3D Visualization Model of Biological Objects)

  • 황헌;최태현;김철수;이수희
    • Journal of Biosystems Engineering
    • /
    • 제26권6호
    • /
    • pp.545-552
    • /
    • 2001
  • Nondestructive methods such as ultrasonic and magnetic resonance imaging systems have many advantages but still much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct a biological object to obtain interior and exterior informations, 3D image visualization model from a series of sliced sectional images gives more useful information with relatively low cost. In this paper, a PC based automatic 3D visualization system is presented. The system is composed of three modules. The first module is the handling and image acquisition module. The handling module feeds and slices a cylindrical shape paraffin, which holds a biological object inside the paraffin. And the paraffin is kept being solid by cooling while being handled. The image acquisition modulo captures the sectional image of the object merged into the paraffin consecutively. The second one is the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last one is the image processing and visualization module, which processes a series of acquired sectional images and generates a 3D volumetric model. To verify the condition for the uniform slicing, normal directional forces of the cutting edge according to the various cutting angles were measured using a strain gauge and the amount of the sliced chips were weighed and analyzed. Once the 3D model was constructed on the computer, user could manipulate it with various transformation methods such as translation, rotation, and scaling including arbitrary sectional view.

  • PDF

Drastic Brightness and Color Variations of the New Discovered Polar OTJ 071126+440405

  • 김용기;윤요나;;;;;한원용
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.59-59
    • /
    • 2012
  • Self-consistent mathematical model of the exotic object OTJ 071126+440405= CSS 081231:071126+440405 is discussed. The system was discovered as a polar at the New year night 31.12.2008/01.01.2009 by D.Denisenko (VSNET Circ), and we have initiated an international campaign of photometric and polarimetric observations of this object (totally -80 runs in Ukraine, Korea, Slovakia, Finland, USA) as a part of the "Inter-Longitude Astronomy" (ILA) project on monitoring of variable stars of different classes (Andronov et al., 2003). Here we present the geometrical and physical model of the system in the low luminosity state and in the intermediate luminosity state as well as in the high luminosity state. As the system is of -20 mag at minimum, no spectral observations were made to determine parameters of the red dwarf. From the statistical relationship, the mass of the red dwarf is estimated to be -0.165 solar masses, for the white dwarf (from eclipse duration) - from 0.5 to 1.76 solar masses. As the system resembles ER UMa in some characteristics, the lower value may be assumed. The inclination of the system and other physical parameters are estimated. The object is an excellent laboratory to study multiple physical processes in the magnetic systems.

  • PDF