• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.028 seconds

Applying the Metaverse Platform and Contents in Practical Engineering Education (공학교육 현장에서의 메타버스 플랫폼 및 콘텐츠 활용)

  • Lee, Yongsun;Lee, Taekhee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.31-43
    • /
    • 2022
  • Recently, metaverse is rapidly expanding its area as a platform that can be applied to various fields. In particular, the function that allows many users to interact in a three-dimensional space allows VR/AR-based educational content to be used as a more advanced concept. Due to the nature of engineering education, it is often based on three-dimensional objects. In the case of a three-dimensional object, it is difficult to explain through two-dimensional videos or documents, and it becomes more difficult to express when the process of changing the object is included. The three-dimensional space of the metaverse can improve this difficulty based on real-time rendering. Another characteristic of engineering education is that there are many invisible elements. Although it is involved in the movement of objects due to electromagnetic fields, magnetic fields, and forces, it is the main reason for increasing learning difficulty because it is invisible. These problems can also help learning because they can be visually represented in the metaverse space. In this paper, the results of the establishment of the metaverse platform for engineering education and the real-time lecture contents produced based on it are described, and the applied results and lecture evaluation are discussed. Lectures using a total of 9 metaverse contents were conducted, and 90% of the positive lecture evaluation results were obtained.

Developing and Adapting an Emotion Model Using Colors for an Emotion Expression (감정표현의 직관성을 향상시키기 위한 색상을 이용한 감정모델의 개발과 적용)

  • Yeo, Ji-Hye;Chung, Myung-Bum;Ham, Jun-Seok;Park, Jun-Hyoung;Ko, Il-Ju
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.152-157
    • /
    • 2008
  • The human uses the optic plentifully that an emotion the human knowledge. by the light it perceives the object and we live middle of color together. The color is close relation in our life. against a color from in many the optic information it is sensitive and it accepts. Therefore if expresses a emotion with color, human knowledge there is a probably of accepting intuition. The purpose of this dissertation to The emotion expression which uses a hue and the hue which leads the relationship research of emotion. In emotional circle of Plutchik, It selects the emotion where becomes the basic and the hue which similar has an impression and feature from the Harris of Moses Harris it searches emotion to use a hue circle with the method which it makes the emotion it expresses. Examines satisfaction of hue and emotion for emotion expression. The magnetic pole of emotion continuously comes in, There must be it will be able to confirm change of many emotion as a real-time. The shooting game the magnetic pole of multi emotion continuously comes in, Because it will be able to confirm the change of emotion as a real-time, suitable the applies for the research of emotion expression Consequently, The application it tried with character hue of shooting game.

  • PDF

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Development of MRI Phantom for Assessing MR Image Quality (자기공명영상 화질 평가용 팬텀 개발에 관한 연구)

  • Ahn, Chang-Beom;Na, Dong-Gyu;Kim, Kwang-Gi;Kim, Dong-Sung;Kim, In-Su;Lee, Jung-Whee;Hong, Suk-Joo;Byun, Jae-Ho;Khang, Hyun-Soo;Jang, Gi-Won;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Purpose : To evaluate MR image qualities we developed a new MRI phantom with the fixation structures necessary to position it into coil firmly. Materials and methods : We designed MRI phantom for eight evaluation items such as slice thickness accuracy, high contrast spatial resolution, low contrast object detectability, geometry accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting and signal to noise ratio. For the positioning of phantom at coils, the fixation structures were set up on the surface of phantom. Six different MRI units were used for test the possibility for the clinical application and their image qualities were evaluated. Results : We acquired appropriate MR image qualities enough for the evaluation on all used MR units and confirmed that their evaluations were within reliable values compared to real ones for some items. The positioning of our phantom into head coils with fixation structures worked well for proper imaging. Conclusion : We found that our prototype of MRI phantom had the possibility of clinical application for MR image quality assessment.

  • PDF

A Study of the Quantitative, Qualitative Analysis on Optimizing Diagnostic Imaging Device Selection in Nasopharynx MRI (비 인두 자기공명 검사 시 최적의 진단영상 장치 선택에 관한 정량, 정성적 평가에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1035-1043
    • /
    • 2019
  • The object of is this research is to find out the optimal Tesla by evaluating SNR and CNR, after testing 1.5 T and 3.0 T. The randomly selected patients tested by nasopharynx MRI transmitted in PACS were applied to the research. Two MRI units(1.5 T, 3.0 T) was used for analyzing the data. As a method of analysis, in T1W highlighting and T1 fat removal images, we set up a certain area of interest and evaluated the SNR and CNR on tongue, spinal cord, masseter muscle, fat, parotid gland, and tumor tissue. We evaluated the SNR and CNR by quantitative analysis of six tissue, measuring the quality of images for uniform fat removal, magnetic sensitivity artifact on a four-point scale by qualitative analysis. The statistical significance of this date analysis was based on independent sample verification and was accepted when the P value was less than 0.05. As a result of analysis of both devices, 3.0 T was high in the quantitative evaluation, while 1.5 T was high in the qualitative evaluation. Considering the advantages and disadvantages of each device, and if the device is selected complementarily and applied to patients, it is believed that it will provide the optimal information.

A Projection-based Intensity Correction Method of Phased-Array Coil Images (위상 배열 코일 영상에서의 밝기 비균등성을 projection에 기반하여 수정하는 방법)

  • Yun SungDae;Chung Jun-Young;Han YeJi;Park HyunWook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Purpose : To develop a novel approach to calculate the sensitivity profiles of the phased array coil for use in non-uniform intensity correction. Materials and Methods : The proposed intensity correction method estimates the sensitivity profile of the coil to extract intensity variations that represent the scanned image. The sensitivity profile is estimated by fitting a non-linear curve to various angles of projections through the imaged object in order to eliminate the high-frequency image content. Filtered back projection is then used to compute the estimates of the sensitivity profile of each coil. The method was applied both to phantom and brain images from 8-channel phased-array coil and 4-channel phased-array coil, respectively. Results : Intensity-corrected images from the proposed method have more uniform intensity than those from the commonly used 'sum-of-squares' approach. By using the proposed correction method, the intensity variation was reduced to $6.1\%$ from $13.1\%$, acquired from the 'sum-of-squares'. Conclusion : The proposed method is more effective at correcting the intensity non-uniformity of the phased-array surface-coil images than the conventional 'sum-of-squares' method.

  • PDF

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

A cognitive psychological consideration of Michael Chehov's acting techniques (미카엘 체홉 연기 테크닉에 대한 인지심리학적 고찰)

  • Jin, Hyun-Chung;Cho, Joon-Hui
    • (The) Research of the performance art and culture
    • /
    • no.37
    • /
    • pp.365-389
    • /
    • 2018
  • This research aims to study Michael Chekhov's acting techniques scientifically, because his techniques has been studied only theoretically or empirically. Especially, this study focuses on 'imagination' and 'Psychological Gesture' from the perspective of cognitive psychology. Chekhov thought 'imagination' as the basis and core of all the works of acting. In cognitive psychology, it is called as 'imagery' and means 'a representation of the mind of the object not communicated by the sensory organs currently'. This study starts with defining imagery and takes a brief look at the features and kinds of imagery. Then the researcher will prove scientifically the possibility of training acting using imagery as Chekhov's assertion. For the proof of the validity of imagery, we'll look for the theoretical evidences-functional equivalence hypothesis, psychoneuromuscular theory, symbolic learning theory, psychophygiological information processing-and experimental ones-measurements of cerebral blood flow or event-related potential, experiments with fMRI(functional magnetic resonance imaging) or PET(positron emission tomography). As a result, we can see that imagery is functionally identical to perception and improves fulfillment of cognitive and physical tasks. As proving physical changes can draw out psychological changes(feeling) on the medium of imagery, we can also see the validity of Psychological Gesture. From the above research, even if Chekhov developed the acting techniques only on the basis of his experience, his techniques can be thought as having scientific validity. Though insufficient, this study can be a help for actors or students as they using Chekhov's techniques.

Indoor Positioning System using Geomagnetic Field with Recurrent Neural Network Model (순환신경망을 이용한 자기장 기반 실내측위시스템)

  • Bae, Han Jun;Choi, Lynn;Park, Byung Joon
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.14 no.6
    • /
    • pp.57-65
    • /
    • 2018
  • Conventional RF signal-based indoor localization techniques such as BLE or Wi-Fi based fingerprinting method show considerable localization errors even in small-scale indoor environments due to unstable received signal strength(RSS) of RF signals. Therefore, it is difficult to apply the existing RF-based fingerprinting techniques to large-scale indoor environments such as airports and department stores. In this paper, instead of RF signal we use the geomagnetic sensor signal for indoor localization, whose signal strength is more stable than RF RSS. Although similar geomagnetic field values exist in indoor space, an object movement would experience a unique sequence of the geomagnetic field signals as the movement continues. We use a deep neural network model called the recurrent neural network (RNN), which is effective in recognizing time-varying sequences of sensor data, to track the user's location and movement path. To evaluate the performance of the proposed geomagnetic field based indoor positioning system (IPS), we constructed a magnetic field map for a campus testbed of about $94m{\times}26$ dimension and trained RNN using various potential movement paths and their location data extracted from the magnetic field map. By adjusting various hyperparameters, we could achieve an average localization error of 1.20 meters in the testbed.

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.