• 제목/요약/키워드: Magnetic Head

검색결과 506건 처리시간 0.039초

Magnetic Wireless Motion Capturing System and its Application for Jaw Tracking System and 3D Computer Input Device

  • Yabukami, S.;Arai, K.;Arai, K.I.;Tsuji, S.
    • Journal of Magnetics
    • /
    • 제8권1호
    • /
    • pp.70-73
    • /
    • 2003
  • We have developed a new tracking system of jaw movement. The system consists of two permanent NdFeB magnets and 32 elements of two-axial fluxgate sensor array, The two magnets are attached to head portion and front tooth. This system does not need any attachments of the head portion or mouth such as clutch or magnetic field sensor except magnets. The proposed system is applicable for five degree of freedom. Position accuracy within 2]m was achieved. We developed a 3D computer input device by using the above mentioned technique.

Correlation between internal derangement and osteoarthrosis in the temporomandibular joint using magnetic resonance imaging

  • Song Haeng-Un;Choi Sun-Young;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제32권4호
    • /
    • pp.221-225
    • /
    • 2002
  • Purpose: To evaluate the relationship between internal derangement and osteoarthrosis in the temporomandibular joint (TMJ) using magnetic resonance imaging (MRI). Materials and Methods: One hundred and six MR images of TMJs in 53 patients were evaluated. Disc displacements and osseous changes of the TMJs were assessed. Lateral and rotational disc displacements were also evaluated on coronal images. Results: No significant differences in the frequency of osseous changes of the TMJs between disc displacement with reduction and disc displacement without reduction groups were found. The erosion of the condylar head and the sclerosis of the articular eminence were more frequent in the internal derangement group than in the no disc displacement group. The flattening was the most frequently observed osseous change of both the condylar head and articular eminence. Conclusion : The relationship between internal derangement and osteoarthrosis is obscure, but it is thought that both disorders adversely affect each other.

  • PDF

연자성재료의 기술현황과 연구동향 (The present technical condition and a trend of research for soft magnetic materials)

  • 양계준;박용관
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권1호
    • /
    • pp.76-92
    • /
    • 1996
  • 본 고에서는 대표적인 연자성재료인 Soft 페라이트, 퍼멀로이, 센더스트와 비정질 자성합금계의 특성과 용도를 살펴봄으로써 현재의 기술현황을 알아보고 그 문제점 해결과 특성개선을 위한 연구동향에 대하여 검토하여 보기로 한다. 또한 연자성재료 일반에 걸쳐 용도별 분류와 각 응용기술 분야에서의 기술동향 및 전망에 대하여 소개하고자 한다.

  • PDF

고화질 VCR용 복합 MIG HEAD (Composite MIG Head for High Definition VCRs)

  • 권상일
    • 한국자기학회지
    • /
    • 제6권1호
    • /
    • pp.7-14
    • /
    • 1996
  • 고밀도화, 광대역화하는 자기기록계의 요구에따라 복합 MIG head를 개발하였다. Head 동특성 측정기와 ME tape를 사용하여 기록 및 재생 특성을 SD VCR 포맷에 대해 검토한 결과, 기록시 20 MHz에서 포화가 발생되지 않았고, 재생시 우수한 상대효율의 주파수 의존성과 접동 잡음특성이 확보됨으로서 C/N 특성의 개선을 도모할 수 있었고 또한 ME tape에 대한 우수한 compatibility는 SD VCR 용 head로서의 적용을 유력하게 하고 있다.

  • PDF

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.

Design and Optimization of 4-Channel SENSE Head Coil

  • 오정민;김용권;류연철;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.16-16
    • /
    • 2003
  • Purpose: Recently, a major interesting method of fast MR imaging is sensitivity encoding (SENSE) using arrays of multiple receiver coils. In this study, we have designed and implemented a 4-channel head array coil and optimized the structure and arrangement of the coil to improve the performance.

  • PDF

수직 기록용 Single Pole Tipe Head의 최적화 설계와 Write Field 분석 (Optimum Design and Analysis of Property of Perpedicular Type Single Pole Write Head)

  • 원혁;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.47-49
    • /
    • 2003
  • 수직 기록 방식은 그 기록 방식의 차이로 인하여 수평 기록 방식에서 쓰여 오던 Write Head의 Design을 적용하였을 경우 기록 밀도를 높이는데 많은 문제점과 낮은 기록 밀도 상승률을 동반하게 된다. 따라서 수직 기록 방식의 자기 기록에서는 수직 기록 방식에 적합한 Write Head의 Design을 적용하여야만 한다. 본 논문에서는 3차원 유한요소법을 이용하여 수직 기록용 Write Head의 한 종류인 SPT Head(Single Pole Tip Head)를 최적 설계하여 그 Write Field의 특성을 분석 제시하였다. 또한 기록 Media의 차이에 따른 기록 특성을 분석하기 위하여 기존 Single Layer 방식과 SUL (Soft Magnetic Under layer)를 사용한 Double Layer 방식을 이용하였을 경우 SUL이 자기 기록에 미치는 영향에 대한 내용을 연구 분석하여 제시하였다.

  • PDF

자기 벡터 포텐셜 해석을 이용한 금속 검출기 코일 헤드의 검출 성능 최적화 (Optimization of the Coil Head of Metal Detectors Using a Magnetic Vector Potential Approach)

  • 오준석;은창수
    • 전자공학회논문지SC
    • /
    • 제46권5호
    • /
    • pp.38-43
    • /
    • 2009
  • 본 논문에서는 자기 벡터 포텐셜 해석을 통해 3-코일 구조를 갖는 금속 검출기 헤드가 수신 코일에 미치는 유도 전압을 구하고, 금속 물체의 특성이 송신 코일의 임피던스에 미치는 영향을 유도하였다. 이러한 해석을 통하여 최적의 검출 성능을 위한 송신 코일과 수신 코일 간의 거리를 구하였고, 최대 유도 전압을 출력하는 금속의 위치를 유도하였다. 또한 기존의 수식과 비교하여 본 논문의 자기 벡터 포텐셜 해석에 대한 타당성을 입증하였다.