• Title/Summary/Keyword: Magnetic Field Measurement

Search Result 518, Processing Time 0.023 seconds

Measurement and Assessment of Absolute Quantification from in Vitro Canine Brain Metabolites Using 500 MHz Proton Nuclear Magnetic Resonance Spectroscopy: Preliminary Results (개의 뇌 조직로부터 추출한 대사물질의 절대농도 측정 및 평가: 500 MHz 고자장 핵자기공명분광법을 이용한 예비연구결과)

  • Woo, Dong-Cheol;Bang, Eun-Jung;Choi, Chi-Bong;Lee, Sung-Ho;Kim, Sang-Soo;Rhim, Hyang-Shuk;Kim, Hwi-Yool;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • The purpose of this study was to confirm the exactitude of in vitro nuclear magnetic resonance spectroscopy(NMRS) and to complement the defect of in vivo NMRS. It has been difficult to understand the metabolism of a cerebellum using in vivo NMRS owing to the generated inhomogeneity of magnetic fields (B0 and B1 field) by the complexity of the cerebellum structure. Thus, this study tried to more exactly analyze the metabolism of a canine cerebellum using the cell extraction and high resolution NMRS. In order to conduct the absolute metabolic quantification in a canine cerebellum, the spectrum of our phantom included in various brain metabolites (i.e., NAA, Cr, Cho, Ins, Lac, GABA, Glu, Gln, Tau and Ala) was obtained. The canine cerebellum tissue was extracted using the methanol-chloroform water extraction (M/C extraction) and one group was filtered and the other group was not under extract processing. Finally, NMRS of a phantom solution and two extract solution (90% D2O) was progressed using a 500MHz (11.4 T) NMR machine. Filtering a solution of the tissue extract increased the signal to noise ratio (SNR). The metabolic concentrations of a canine cerebellum were more close to rat’s metabolic concentration than human’s metabolic concentration. The present study demonstrates the absolute quantification technique in vitro high resolution NMRS with tissue extraction as the method to accurately measure metabolite concentration.

  • PDF

Preparation and Characterization of NiZn-Ferrite Nanofibers Fabricated by Electrospinning Process (전기방사법에 의한 NiZn 페라이트 나노섬유의 제조 및 특성 연구)

  • Joo, Yong-Hui;Nam, Joong-Hee;Cho, Jeong-Ho;Chun, Myoung-Pyo;Kim, Byung-Ik;Ko, Tae-Gyung
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Electrospinning process is the useful and unique method to produce nanofibers from metal precursor and polymer solution by controlled viscosity. In this study, the NiZn ferrite nanofibers were prepared by electrospinning with a aqueous metal salts/polymer solution that contained polyvinyl pyrrolidone and Fe (III) chloride, Ni (II) acetate tetrahydrate and zinc acetate dihydrate in N,N-dimethylformamide. The applied electric field and spurting rate for spinning conditions were 10 kV, 2 ml/h, respectively. The obtained fibers were treated at $250^{\circ}C$ for 1 h to remove the polymer. Finally, the NiZn ferrite fibers were calcined at $600^{\circ}C$ for 3 h and annealed at $900{\sim}1200^{\circ}C$ in air. By tuning the viscosity of batch solution before electrospinning, we were able to control the microstructure of NiZn ferrite fiber in the range of $150{\sim}500\;nm$ at 770 cP. The primary particle size in $600^{\circ}C$ calcined ferrite fiber was about 10 nm. The properties of those NiZn ferrite fibers were determined from X-ray diffraction analysis, electron microscopy, energy dispersive spectroscopy, Fourier transform infrared spectroscopy, thermal analysis, and magnetic measurement.

Features and Statistics on the Magnetic Field Waveforms Radiated by Intracloud Discharges (운방전에 의해서 방사된 자계 파형의 특징과 통계)

  • Lee, Bok-Hee;Lee, Dong-Moon;Cho, Sung-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.59-66
    • /
    • 2005
  • This paper presents some features and statistics of electromagnetic pulses radiated from intracloud lightning discharges. The LabVIEW based-measurement system of time-dependent electromagnetic fields was constructed. The frequency bandwidth of the measuring system ranged from 300[Hz] to 1[MHz], and the response sensitivity was 2.78(mV/nT). The resolution and the maximum recording length of the data acquisition system were 12(bits) and 100[ms], respectively. In the electromagnetic pulses radiated from intracloud discharges, a pronounced bipolar pulse appeared with one or more fast pulses superimposed on the initial front part of the bipolar pulse. The mean duration of intracloud discharges was $1.05{\pm}0.32[ms]$, and an average of about 8 outburst pulses appeared for a period.

Design of a CMOS RFID Transponder IC Using a New Damping Circuit (새로운 감폭회로를 사용한 CMOS RFID 트랜스폰더 IC 설계)

  • O, Won-Seok;Lee, Sang-Hun;Lee, Gang-Myeong;Park, Jong-Tae;Yu, Jong-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.211-219
    • /
    • 2001
  • This paper describes a read-only CMOS transponder IC for RFID applications. A full-wave rectifier implemented using NMOS transistors supplies the transponder with a dc supply voltage using the magnetic field generated from a reader. A 64-bit ROM has been designed for a data memory. Front-end impedance modulation and Manchester coding are used for transmitting the data from the transponder memory to the reader. A new damping circuit which has almost constant damping rate under the variations of the distance between the transponder and the reader has been employed for impedance modulation. The designed circuit has been fabricated using a 0.65${\mu}{\textrm}{m}$2-poly, 2-metal CMOS process. Die area is 0.9mm$\times$0.4mm. Measurement results show that it has a constant damping rate of around 20~25% and a data transmission rate of 3.9kbps at a 125KHz RF carrier. The power required for reading operation is about 100㎼. The measured reading distance is around 7cm.

  • PDF

Non-Contact Current Sensor Fabricated with LC Resonators (LC 공진소자를 이용한 비접촉 전류센서 연구)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.137-141
    • /
    • 2016
  • There is a growing demand for non-contact current measurements for efficient use of electrical power and energy saving. In this study, I propose a non-contact current sensor using LC resonance by a resonance circuit composed of a sensor coil and 2 coupling coils for enabling a wireless measurement. The inductance of the sensor coil, which could be changed by applied current, causes the change of resonance frequency of the resonance circuit. A pair of magnet was attached to the ferrite core to apply a bias magnetic field that enabled the determination of the current direction. We obtained an output voltage change of 18 V with the current of -3~3 A. But, the output was nonlinear. In order to realize the non-contact current measuring method proposed in the present study, there is a need for a strict investigation of linearity and resolution for the future study.

A Study on the Fabrication of Polarimetric Fiber Optic Current Sensor (편광측정법에 의한 광섬유 전류 센서 제작에 관한 연구)

  • Jang, Nam-Young;Chio, Pyung-Suk;Eun, Jae-Jeong;Park, Hae-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.33-41
    • /
    • 2004
  • In this paper, a polarimetric fiber optic current sensor(P-FOCS) is experimented and fabricated, and then a possibility to the commercial utilization of the P-FOCS is also investigated. The P-FOCS measures an applied current by a Faraday rotation linearly proportional to a magnetic field generated by the applied current. The bending-induced linear birefringence in the sensing fiber is minimized by using the low birefringent fiber. Also, all fiber-optic components are used to avoid optical losses coming from the use of bulk components. A signal processing circuit is constructed and used to eliminate the effects of intensity variations in the output signal due to losses coming from misalignments of components such as fiber connectors. Using the optical source of 632.8nm wavelength, Faraday rotation is measured by passing through the sensing fiber within the solenoid of about 1500 turns which is equivalent to a current source of about 7500A. In the range of 1000A to 7500A, the measurement error for linearity is within about 1.5%.

Feasibility study on the development of respiration sensor using a chalcogenide optical fiber (Chalcogenide 광섬유를 이용한 호흡측정 센서 개발을 위한 기초 연구)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Oh, Jeong-Eun;Lee, Bong-Soo;Tack, Gye-Rae
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.331-336
    • /
    • 2007
  • In this study, we have fabricated an infrared optical fiber based sensor which can monitor the respiration of a patient. The design of a chalcogenide optical fiber based sensor is suitable for insertion into a high electro-magnetic field environment because the sensor consists of low cost and compact mid-infrared components such as an infrared light source, a chalcogenide optical fiber and a thermopile sensor. A fiber-optic respiration sensor is capable of detecting carbon dioxide ($CO_{2}$) in exhalation of a patient using the infrared absorption characteristics of carbon gases. The modulated infrared radiation due to the presence of carbon dioxide is guided to the thermopile sensor via a chalcogenide receiving fiber. It is expected that a mid-infrared fiber-optic respiration sensor which can be developed based on the results of this study would be highly suitable for respiration measurements of a patient during the procedure of an MRI.

Magnetoresistance effects in [Co/Cu/NiFe/Cu] Spin-valve Multilayers ([Co/Cu/NiFe/Cu] 다층박막의 자기저항효과에 관한 연구)

  • 정진봉;박창만;이기암;황도근;이상석
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.203-209
    • /
    • 1995
  • A study of the dependence of the magnetoresistance in $glass\[Cu_{x\AA}\NiFe_{50\AA}\Cu_{x\AA}\Co_{50\AA}](X;\=\;8,\;10,\;14,\;18,\;22,\;26,\;28,\;38,\;48,\;58\;\AA,\;N\;=\;2,\;3,\;4,\;10,\;20)$ multilayers prepared by dc magnetron sputtering on the interlayer thickness of Cu (X), the number of multylayer(N) and annealing temperature has been performed. Resistance measurement were made by four terminal method, and the magnetic field applied to perpendicular and parallel for the current. The maximum magnetoresistance(MR) ratio(%) was appeared in the vicinity of $10\;\AA$ in Cu layer, and it was oscillated with the thickness of Cu. The MR ratio was increased with the number of layers N, however the ratio for the N = 4 layers decreased rather than the N = 3 layers. The dependence of the ratio on the annealing temperature was increased to $250^{\circ}C$.

  • PDF

Development and Application of Wireless Power Transmission Systems for Wireless ECG Sensors (지속적인 심장질환 모니터링을 위한 인체 삽입형 생체 센서의 무선전력전송 시스템)

  • Heo, Jin-Chul;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.111-117
    • /
    • 2019
  • We investigated the variations in the magnetic-field distribution and power transmission efficiency, resulting from changes in the relative positions of the transmitting and receiving coils, for electromagnetic-induction-type wireless power transmission using an elliptical receive coil. Results of simulations using a high-frequency structure simulator were compared to actual measurement results. The simulations showed that the transmission efficiency could be maintained relatively stable even if the alignment between the transmitting and receiving coils was changed to some extent. When the centre of the receiving coil was perfectly aligned with the centre of the transmitting coil, the transmission efficiency was the maximum; however, the degree of decrease in the transmission efficiency was small even if the centre of the receiving coil moved by ± 10mm from the centre of the transmitting coil. Therefore, it is expected that the performance of the wireless power transmission system will not be degraded significantly even if perfect alignment is not maintained. The results suggested a standardized application method of wireless transmission in the utilization of wireless power for implantable sensors.

Cable Tension Measurement of Long-span Bridges Using Vision-based System (영상처리기법을 이용한 장대교량 케이블의 장력 측정)

  • Kim, Sung-Wan;Cheung, Jin-Hwan;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • In a long-span bridge, the cables are important elements that support the load of the bridge. Accordingly, the cable tension is a very important variable in evaluating the health and safety of the bridge. The most popular methods of estimating the cable tensions are the direct method, which directly measures the cable stresses using load cells, hydraulic jacking devices, etc., and the vibration method, which inverses the tensions using the cable shapes and the measured dynamic characteristics. Studies on the use of the electromagnetic (EM) sensor, which detects the magnetic field variations caused by the change in the stress of the steel in the cable, are increasing. In this study, the lift-off test, the EM sensor, and the vibration method (Vision-based System and Accelerometer) were used to measure cable tension, and their results were compared and analyzed.