• Title/Summary/Keyword: Magnetic Contact

Search Result 417, Processing Time 0.033 seconds

The Development of Magnetic Field Measurement System of 3 Axis (3축 자계 측정 시스템의 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.

Magnetic Nerve Stimulation Coils with Magnetic Mirror Effect (자계 거울 효과를 이용한 신경 자극 코일)

  • 한병희;김기왕;김재곤;박태석;이수열;조민형;양종수;김정회
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.287-293
    • /
    • 2002
  • For non-contact nerve stimulations using time varying magnetic field, high amplitude current pulses have to be applied to a magnetic nerve stimulation coil. To increase the magnetic stimulation frequency we have to increase both power supply capacity and cooling capacity of the magnetic nerve stimulator. To alleviate these problems. we propose a new magnetic nerve stimulation coil design methods. Utilizing magnetic mirror effect of a ferro-magnetic plate attached to a magnetic stimulation coil. we have improved efficiency of the stimulation coil. We have analyzed magnetic mirror effect for various kinds of stimulation coils using the finite element method, and we present experimental results obtained with several kinds of stimulation coils.

Study on the Active Vibration Control of Magnetic Bearing System using $H_{\infty}$ Controller (능동 자기 베어링 제어를 위한 $H_{\infty}$ 제어기 설계)

  • 고무일;이경백;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.303-306
    • /
    • 1997
  • Magnetic bearings have been adopted to support the rotor by electromagnetic force without mechanical contact and have many advantages. The application of the magnetic bearings have become more and more widespread in recent years. But magnetic bearings require feedback control for stable operation because they are inherently open loop unstable systems. In this study, H infinity controller has been applied for rotor-magnetic bearing system for vibration control. The result showed that H infinity controller has better performance than PID controller through simulations.

  • PDF

Robust Control of Disturbed Magnetic Bearing Rotor Systems (외란을 받는 자기베어링 주축계의 강건제어)

  • 강호식;송오섭
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.40-46
    • /
    • 2004
  • Magnetic bearing has been adopted to support a rotor by electromagnetic force without mechanical contact and lubrication process. The recent growth of magnetic bearing applications in many industrial fields requires more accurate design of bearing-rotor system. Due to external forces and uncertainties of magnetic bearing system the actual performance and stability my be worse than it is designed. This paper describes the governing equations of rotor magnetic bearing systems and/or the designing of robust controller via standard $H_{\infty}$ control problem. The system stability and response characteristics are studied by simulations and verified with experimental results.

A Simple a.c. Magnetic Susceptometer Using self-inductance Measurement of a Single Coil Mounted on a Cryostat Cold Head

  • Dho, Joong-Hoe
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.177-181
    • /
    • 2008
  • A very simple a.c. magnetic susceptometer for use in a helium closed cycle cryostat is reported in this paper. This simple setup has only a single bobbin-less copper coil, instead of the primary coil and two secondary coils typically used in mutual-inductance types. The single bobbin-less copper coil is directly mounted on the cryostat cold head. A sample is attached on the inside wall of the copper coil using a thermal contact material and its a.c. magnetic susceptibility is obtained from the measurement of the self-inductance of the sample coil using an LCR meter or an impedance analyzer. Experimental details are described and illustrative measurements on magnetic and superconducting materials as a function of temperature are included. The performances and limitations of this simple a.c. magnetic suceptometer are also discussed.

Influence of Machining on Magnetic Properties of Soft Magnetic Composites

  • Igarashi, Kazunori;Miyahara, Masahisa;Morimoto, Koichiro
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1175-1176
    • /
    • 2006
  • Influences of machining on magnetic properties of soft magnetic composites (SMC's) with addition of two kinds of binder, i.e., organic binder and inorganic one, were investigated. Machining does not affect DC magnetic properties of the SMC compacts. This can be ascribed to their particular structure in which the ironpowder particles are highly isolated by the binder. On the other hand, decrease in resistivity and resultant increase in eddy current loss was confirmed in the machined compacts containing inorganic binder. It is supposed that the brittleadditive binder existing between the iron particles is partly broken, and iron-to-iron contact is formed on the machined surface.

  • PDF

A Non-contact Detection Method for Smelting in Submerged Arc Furnace based on Magnetic Field Radiation

  • Liu, WeiLing;Chang, XiaoMing
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.204-208
    • /
    • 2016
  • This paper demonstrates the key parameter detection for smelting of submerged arc furnace (SAF) based on magnetic field radiation. A magnetic field radiation model for the inner structure of SAF is established based on relative theory of electromagnetic field. A simple equipment of 3D magnetic field detection system is developed by theoretical derivation and simulation. The experiments are carried out under the environment of industrial field and AC magnetic field generated by electrode currents and molten currents in the furnace is reflected outside of the furnace. The experimental results show that the key parameters of smelting including the position of electrode tip, the length of electric arc, and the liquid level of molten bath can be achieved. The computed tomography for SAF can be realized by the detection for smelting.

A Study on the Shape Evaluation using Non-contact Electromagnetic Measurement System (비접촉식 전자기 측정 시스템에서 자성물체의 형상판정에 관한 연구)

  • Kim, Jae-Min;Yun, Seung-Ho;Won, Hyuk;Park, Gwan-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.45-51
    • /
    • 2010
  • We suggest the algorithm that it detects volume and shape according with a variation of magnetic field in non-contact electromagnetic measurement system. It is possible to assess an object shape through a variation of magnetic field. The basic idea is compared a length difference with a variation of magnetic field in a detected object and a circle which modeled equivalent area. And the shape is detected to many calibration process that it is similar to signal pattern between a length difference and a variation of magnetic field in object and equivalent circle. This is the shape detection algorithm that use only the variation of magnetic field. In this paper, it has application to the shape detection algorithm about the object as hexagon, pentagon, rectangle, trigon. we can detect the object shape easily because the shape detection algorithm is only used to the variation of magnetic field.

225[AF]/200[A]/50[kA] 배선용 차단기 고정자 변화를 통한 차단용량 향상

  • Lee, Seung-Su;Yun, Jae-Hun;Jeong, Ui-Hwan;Im, Gi-Jo;Gang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.221-221
    • /
    • 2009
  • This paper is focused on understanding the interrupting capability, more specifically of the fix contact, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

The Dynamic Characteristics Analysis Between Pantograph and Catenary System Using Block Pulse Function (블럭펄스함수를 이용한 판토그래프와 가선시스템사이의 동특성 해석)

  • Shin, Seung-Kwon;Song, Yong-Soo;Eum, Ju-Hwan;Eum, Ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.748-750
    • /
    • 2004
  • The pantograph should supply the electrification equipments of a train with the current from the overhead catenary system over a broad range of speeds. For a high-speed electrical train, the dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force. As the operational speed increases, the variation of the contact force increases. The contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the dynamic characteristics analysis between pantograph and catenary system using block pulse function.

  • PDF