• 제목/요약/키워드: Magnet shim

검색결과 41건 처리시간 0.034초

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

MRI 마그네트용 보정코일 설계 (Design of the Shimming Coils for MRI Magnet)

  • 배준한;고락길;진홍범;심기덕;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

Design and Test Results of an Actively Shielded Superconducting Magnet for Magnetic Resonance Imaging

  • Jin, Hong-Beom;Ryu, Kang-Sik;Oh, Bong-Hwan;Ryu, Kyung-Woo;Jeoun, In-Young
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.95-105
    • /
    • 1997
  • In this paper, we have studied about design and fabrication of the actively shielded superconducting MRI magnet. Nonlinear optimization methods are usually used to find optimum coil configurations. However the selection of initial coil configurations is very difficult. In case bad initial data are used, it is even impossible to find optimum coil configurations which satisfy predefined constraints. We have developed computer optimization program which consists of two steps. Initial coil configurations are easily selected through linear optimization in the first step and optimum coil configurations are found through nonlinear optimization in the second step. We have also studied about superconducting shim coils to cancel error fields caused by coil fabrication errors. Many researchers published design concepts of shim coil. However all these studies are for shim coil design using filamentary coils with single turn, Shim coils with multi-turns should be used to produce enough field strength to cancel error fields. We have developed computer program for the design of shim coils which have proper thickness and length. An actively shielded superconducting MRI magnet with a small warm bore was fabricated and four sets of superconducting shim coils were equipped. The magnetic field distributions were measured and field correction was carried out using shim coils.

  • PDF

중자장급 보급형 국산 초전도 MRI 마그네트 개발 (The Development of Popular type Domestic Superconducting MRI Magnet with Middle Magnetic Field Range)

  • 배준한;고락길;심기덕;진흥범;조전욱;이언용;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.22-25
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

Passive shimming design with commercially available rectangular shim sheets on a cylinder for HTS NMR magnets

  • Ahn, Min Cheol
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권2호
    • /
    • pp.29-33
    • /
    • 2018
  • Although high-temperature superconducting (HTS) magnets have the potential merit of producing ultra-high field (>25 T), they have been not easy to apply to Nuclear Magnetic Resonance (NMR) because of the difficulty of field homogeneity improvement. This paper presents a design technique of passive shimming for HTS magnets. Ferromagnetic shimming design code was developed though MALAB, which includes the optimization algorithm. The proper shim element size was determined by a simulation. This design technique was verified by a case study design of a 3-T HTS magnet. We succeed to improve field homogeneity of the magnet from 634 ppm to 6.39 ppm at 10-mm diameter sphere volume. Feasibility of passive shimming for all-HTS NMR magnet was confirmed by this result.

Spin transport studies in organic semiconductors and spin filter tunneling

  • Moodera, Jagadeesh;Santos, Tiffany S.;Shim, Jenny;Lee, Joo-Sang;Park, Young-Ju;Nagahama, Taro;Miao, Guo-Xing;Venkataraman, Karthik;Choi, Deung-Jang
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2007년도 동계학술연구발표회 및 스핀트로닉스와 나노물리에관한 국제심포지움
    • /
    • pp.17-17
    • /
    • 2007
  • PDF

Insert dewar를 이용한 초전도 MRI 마그네트의 자장분포 평가 (Magnetic Field Distributions of Superconducting MRI Magnet in Insert Dewar)

  • 진홍범;오봉환;권영길;오상수;조전우;하동우;이언용;류경우;류강식;한일용;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.137-140
    • /
    • 1995
  • This paper describes the test results of magnetic field distributions of superconducting MRI magnet in an insert dewar. To get a very high homogeneous magnetic field, various shim coils are installed besides the main magnet. The operating currents of each shim coils are obtained from the exact measurements of the magnetic field. In this paper, we report the test results of the magnetic field distribution measurements with various shim coils.

  • PDF

부분 자기 차폐된 마그네트 휠의 선형구동기로의 응용 (Linear Actuator using Magnetic Shield of Rotating Magnet Wheel)

  • 심기본;박준규;이상헌;정광석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.923-925
    • /
    • 2008
  • As known generally, when permanent magnets whose poles are upward and downward in order, arranged into the circumferential direction rotate under the conducting plate, the rotating force acts on the plate as well as the repulsive force. If the magnetic field by the magnet wheel(the above rotating permanent magnets) is partially shielded, the magnet wheel over open region can be a linear induction motor. The distinct feature from induction motor is that the traveling magnet field is produced by the moving permanent magnet instead of ac current. Furthermore, a variation of the open region changes the direction of the thrust force. In this paper, we introduce a concept of the linear actuator using the magnet wheel. Under the above shielding condition, a few simulation results and its verification from a simple test setup are described.

  • PDF

Design of ferromagnetic shims for an HTS NMR magnet using sequential search method

  • Yang, Hongmin;Lee, SangGap;Ahn, Minchul
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.39-43
    • /
    • 2021
  • This study deals with the ferromagnetic shims design based on the spherical harmonic coefficient reduction method. The design method using the sequential search method is an intuitive method and has the advantage of quickly reaching the optimal result. The study was conducted for a 400 MHz all-REBCO magnet, which had difficulty in shimming due to the problem of SCF (screening current induced field). The initial field homogeneity of the magnet was measured to be 233.76 ppm at 20 mm DSV (Diameter Spherical Volume). In order to improve the field homogeneity of the magnet, the ferromagnetic shim with a thickness of 1 mil to 11 mil was constructed by a design method in which sequential search algorithm was applied. As a result, the field homogeneity of the magnet could be significantly improved to 0.24 ppm at 20 mm DSV and 0.05 ppm at 10 mm DSV.

원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교 (Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging)

  • 김용권;현정호;서증훈;김혁기;오창현
    • 전자공학회논문지SC
    • /
    • 제48권6호
    • /
    • pp.57-62
    • /
    • 2011
  • 본 논문에서는 초전도 자석의 자장 균일도를 개선하기 위한 방법으로 3가지 형태의 magnet 모델을 제안하고 각각의 자석 형태에 대하여 같은 세기의 자장을 (Magnet field strength) 가질 경우에 최소전력 방식으로 최적화된 전류 분포에 해당하는 coil wire의 길이, 그리고 해당 조건에서의 자장의 불균일도를 시뮬레이션을 통하여 비교, 분석하였다. 구성된 3가지 magnet type을 동일한 조건 (계산 점의 개수 18개, 20cm DSV)에 대해서 wire길이와 main field inhomogeneity를 비교하였으며, 이러한 시뮬레이션 결과를 통하여 얻을 수 있는 결론은 계산점의 수가 적을수록 wire의 길이는 짧아지나 field inhomogeneity는 높아진다는 것이다. 즉, Magnet shim을 수행할 경우 계산점을 줄이는 방법으로는 짧은 wire의 길이와 main field homogeneity를 동시에 만족하도록 최적화 하는 것이 거의 불가능함을 의미하는 것이다. 그러나 DSV를 줄였을 경우에 계산점을 줄였을 때에 비해 우수한 결과 값을 얻을 수 있었다. 결론적으로 공간적으로 개방되어 있는 magnet model의 경우 계산점을 줄여 shimming을 진행할 경우 동일한 imaging region의 크기에 대해 더 많은 전류(또는 wire 길이)가 필요하고 field 균일도도 떨어졌으나 작은 ROI를 대상으로 영상을 얻는 경우 유용하게 사용될 수 있다.