인슐레이션을 제거한 소형 초전도 회전자 디자인 (Design of a small size insulationless superconducting rotor)

  • 김광민;정성준;김경훈;김남원;박민원;유인근;박태준;김태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.792-793
    • /
    • 2011
  • The purpose of this paper is to study the thermal and mechanical characteristics of HTS (high temperature superconductor) field magnet according to the design of a small size superconducting rotor without insulation. First, basic design data of superconducting rotor were acquired through electromagnetic analysis. Based on these data, analysis regarding mechanical and thermal characteristics of HTS field magnet was executed. Anisotropic condition was considered in the mechanical characteristics of HTS field magnet. Average values of specific heat and heat conductivity up to 30 K were used during the analysis of thermal characteristics. Analysis results show superior mechanical and thermal characteristics of insulationless HTS field magnet compared with insulated HTS field magnet.

  • PDF

MRI 마그네트용 보정코일 설계 (Design of the Shimming Coils for MRI Magnet)

  • 배준한;고락길;진홍범;심기덕;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

NMR/MRI Superconducting Magnet Technologies: Recent Activities at MIT Francis Bitter Magnet Laboratory

  • Yukikazu Iwasa;Lee, Haigun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.1-12
    • /
    • 2003
  • In this paper we present a brief description and summary results of each of our recent activities in three areas, all devoted to NMR and MRI superconducting magnet technologies: 1) development of a high-field LTS / HTS NMR magnet; 2) development of a novel digital flux injector for slightly resistive NMR magnets; and 3) a proposal fer a low-cost MRI magnet system based on $MgB_2$ composite and an innovative cryogenic design / operation concept.

General Analytical Method for Magnetic Field Analysis of Halbach Magnet Arrays Based on Magnetic Scalar Potential

  • Jin, Ping;Yuan, Yue;Lin, Heyun;Fang, Shuhua;Ho, S.L.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.95-104
    • /
    • 2013
  • This paper presents a general analytical method for predicting the magnetic fields of different Halbach magnet arrays with or without back iron mounted on slotless permanent magnet (PM) linear machines. By using Fourier decomposition, the magnetization components of four typical Halbach magnet arrays are determined. By applying special synthetic boundary conditions on the PM surfaces, the expressions of their magnetic field distributions are derived based on the magnetic scalar potential (MSP), which are simpler than those based on the magnetic vector potential (MVP). The correctness of the method is validated by finite element analysis. The harmonics of airgap flux density waveforms of these Halbach magnet arrays with or without back iron are also compared and optimized.

영구자석형 동기전동기의 약계자제어에 관한 연구 (A study on Field-Weakening Control for Permanent Magnet Synchronous Motor)

  • 이철균;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.5-9
    • /
    • 1990
  • A permanent magnet synchronous motor(PMSM) differs from an ordinary synchronous motor in that the former has no field winding and the field flux can not be controlled by field current. A field-weakening control of PMSM utilizing the demagnetization due to d-axis armature reaction is equivalent to reducing the field current. In this paper, the armature resistance is considered for the optimum field-weakening control.

  • PDF

전자기 구동 유영 마이크로로봇 (Swimming Microrobot Actuated by External Magnetic Field)

  • 변동학;김준영;백승만;최현철;박종오;박석호
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1300-1305
    • /
    • 2009
  • The various electromagnetic based actuation(EMA) methods have been proposed for actuating microrobot. The advantage of EMA is that it can provide wireless driving to microrobot. In this reason a lot of researchers have been focusing on the EMA driven microrobot. This paper proposed a swimming microrobot driven by external alternating magnet field which is generated by two pairs of Helmholtz coils. The microrobot has a fish-like shape and consists of a buoyant robot body, a permanent magnet, and a fin. The fin is directly linked to the permanent magnet and the magnet is swung by the alternating magnet field, which makes the propulsion and steering power of the robot. In this paper, firstly, we designed the locomotive mechanism of the microrobot boy EMA. Secondly, we set up the control system. Finally, we demonstrated the swimming robot and evaluated the performance of the microrobot by the experiments.

Field Circuit Coupling Optimization Design of the Main Electromagnetic Parameters of Permanent Magnet Synchronous Motor

  • Zhou, Guang-Xu;Tang, Ren-Yuan;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.88-93
    • /
    • 2008
  • The electromagnetic parameters of a permanent magnet synchronous motor (PMSM) such as the open load permanent magnet flux, d axis reactance $X_d$, and q axis reactance $X_q$, are most essential to the performance analysis and optimization design of the motor. Based on the numerical analysis of the 3D electromagnetic field, the three electromagnetic parameters of permanent magnet synchronous motors with U form interior rotor structures are calculated by FEA. The rules of the leakage coefficient and reactance parameters changing with the air gap length, permanent magnet magnetism length, and isolation magnetic bridge dimensions in the rotor are given. The calculated values agree well with the measured values. The FEA results are integrated with the self compiled electromagnetic design program to optimize the prototype motor. The tested performances of the prototype motor prove that the method is suitable for the optimization of motor structure.

홀센서를 이용한 자석의 위치인식 센서 개발 (Magnet Position Sensor System using Hall Sensors)

  • 김은주;김의선;임영철
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제5권2호
    • /
    • pp.166-172
    • /
    • 2011
  • 저가의 홀센서를 이용하여 자석의 위치를 인식하는 센서 시스템을 제안하였다. 먼저 모델식을 이용하여 자석에 의한 자기장을 측정하고, 수평 자계와 수직 자계의 특성을 분석하여, 센서의 배치방법을 결정하였다. 자석과 홀센서의 위치 관계에 따라서 측정된 자기장 값으로부터 자석의 위치를 추정하는 알고리즘을 제안하고, 이론적인 오차를 계산하였다. 또한 마이크로 컨트롤러를 사용하여 개발할 때의 단점인 실시간 데이터 확인이 어려운 점을 극복하기 위해서 컴퓨터용 응용 프로그램을 작성하여, 작업의 수월성을 높였다. 계산된 이론적 오차는 0.0025cm 이하로 나타났으며 실제로 개발된 시스템의 오차는 0.07cm 이하로 측정되어 여러 가지 상황에서 제안한 방법들의 우수성을 입증하였다.

Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor

  • Kiyoumarsi, Arash
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.370-376
    • /
    • 2009
  • The influence of magnetic saturation on electromagnetic field distribution in both a permanent-magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.

초전도자석의 영구전류모드 운전시 초기자장감쇠 (The Initial Magnetic Field Decay of the Superconducting Magnet in the Persistent Current Mode)

  • 배준환;심기덕;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.31-34
    • /
    • 2000
  • this paper deals with the initial magnetic field decay for a large scale superconducting magnet e.g. NMR/MRI magnet. The high resolution image can not be obained during the periods of the initial field decay. It is known that all superconducting materials have the property of diamagnetism. This diamagnetism is usually explained with the concept of screening current. We assumed that the existence of the screening currebt. we assumed that the existence of the screening current makes the current distribution in the superconducting wire non-uniform. And the initial magnetic field decay is caused steady current state in the view of its pattern. The initial magnetic field decay is caused by the change of the current distribution between the energizing state and persistent current mode. in this paper the theoretical analysis for the current distributions has been introduced for each state. The experiments have been carried out to verify transport currents in order to veperiments, it small at the higher transport current.

  • PDF