• Title/Summary/Keyword: Machinery Noises

Search Result 35, Processing Time 0.022 seconds

development of an ear-muff with active noise control for selective noise attenuation (특정주파수 소음제거를 위한 능동소음제어식 청각보호구 개발연구)

  • Kim, Dong-Gyun;Kim, Ok-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2068-2072
    • /
    • 1997
  • Acoustic noise has become an increasingly important issue, especially in the industrial environment. Nowadays home and office are not exceptional, mainly due to the increase in the usage of machinery. Active Noise Control(ANC) becomes efficiently an available tool for the noise suppression with rapid advances of solid state electronics. In this study an ANC system is developed for audio headphone to work as a noise protector, so called an ear-muff. The system is developed to kill a certain frequency band noises selectively which is purposed to suppress only the dominant ambient noise such that normal numan conversation is not disturbed with wearing the ear-muff. For the purpose, an ANC design strategy is suggested and implemented with an analogue control circuit. The performance is evaluated by frequency response test, which shows well consistence with theoretical one. The results are so satisfactory that noise of 640 Hz, which is aimed to suppress, is reduced by 20db without significant distortion in other frequency band.

Prediction of Non-cavitation Noise from Large Scale Marine Propeller (수치해석을 통한 대형 선박용 프로펠러의 비공동소음 예측)

  • Ryu, Ki-Wahn;Lee, Jong-Yeol;Kim, Bong-Ki;Byun, Jeong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.75-82
    • /
    • 2015
  • Noises from the large scale marine propeller are calculated numerically on non-cavitation condition. The hydrodynamic analysis is carried out by potential based panel method with time marching free wake approach. The distribution of hydrodynamic loads on the propeller surface and noise signals are obtained using the unsteady Bernoulli's equation and the Farasssat's formula respectively. It turns out that the noise signal at the narrow band shows strong peak at the blade passage frequency, and the peak value at the 1/3 octave band also shows the same trend. Noise signals and directivity patterns for both the thickness and the loading noise are compared with each other. The directivity pattern for the loading noise shows minor lobe at the backward side of the rotating disc plane.

Soft Switched Three-Phase Single Switch Boost-Type Converter (소프트 스위칭 3상 단일 스위치 승압형 컨버터)

  • Mun, S.P.;Jun, C.W.;Pack, S.U.;Kim, D.U.;Kim, Y.M.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1166-1168
    • /
    • 2003
  • In most power electronic applications, the AC power input provided by the electronic utility needs to first converted to a DC voltage. Such conversion is accomplished by a diode rectifier due to its circuit simplicity and low cost. However, since diode rectifiers have some intrinsic problems such as low power factor and high harmonic distortion, a wide use of such rectifiers may cause noises, malfunction and heat damage in both electrical power systems and electrical machinery systems. This paper proposes soft switched three-phase single switch boost-type converter. The proposed circuit can perform Zero Voltage Switched(ZVS) without using any current and voltage sensors. For this circuit, both simulation and experiments have been performed. The results not only confirmed the ZVS but also indicated that, compared to the conventional hard switched converter, the prosed circuit can improve the efficiency as much as 1.7 to 4.7[%] while keeping the same high power factor and small harmonic distortion in their AC input.

  • PDF

Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기의 운전특성)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

Development of Squirrel-Cage Induction Motor for 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기 개발)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.57-68
    • /
    • 2014
  • This paper propose a development of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase ac machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. Designed methods of the motor use a development tools with Maxwell 2D and Simplorer program. There are designed drawing of manufactured frames of the IM. amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages and current, and reviewing a experiment results are shown by variable output. We are presenting a design and manufacture methods for the 5-phase squirrel-cage IM.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.

Automatic Machine Fault Diagnosis System using Discrete Wavelet Transform and Machine Learning

  • Lee, Kyeong-Min;Vununu, Caleb;Moon, Kwang-Seok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1299-1311
    • /
    • 2017
  • Sounds based machine fault diagnosis recovers all the studies that aim to detect automatically faults or damages on machines using the sounds emitted by these machines. Conventional methods that use mathematical models have been found inaccurate because of the complexity of the industry machinery systems and the obvious existence of nonlinear factors such as noises. Therefore, any fault diagnosis issue can be treated as a pattern recognition problem. We present here an automatic fault diagnosis system of hand drills using discrete wavelet transform (DWT) and pattern recognition techniques such as principal component analysis (PCA) and artificial neural networks (ANN). The diagnosis system consists of three steps. Because of the presence of many noisy patterns in our signals, we first conduct a filtering analysis based on DWT. Second, the wavelet coefficients of the filtered signals are extracted as our features for the pattern recognition part. Third, PCA is performed over the wavelet coefficients in order to reduce the dimensionality of the feature vectors. Finally, the very first principal components are used as the inputs of an ANN based classifier to detect the wear on the drills. The results show that the proposed DWT-PCA-ANN method can be used for the sounds based automated diagnosis system.

Development of Hydrophilic Performance Measurement System for Anti-Condensation Using Computer Image (컴퓨터 영상을 이용한 오염방지 친수성능 측정 시스템 개발)

  • Ahn, Byung-Tae;Cho, Sung-Ho;Choi, Sun;Kim, Eun-Kuk;Park, Sang-Soo;Hwang, Heon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.257-261
    • /
    • 2010
  • Surface energy is the principal factor of anti-condensation. High surface energy appears hydrophilic itself and low surface energy represents hydrophobic itself. The contact angle is widely being used for measurement of surface energy of materials, evaluation of coating performances, measurement of wettability, and so on. However, the existing contact angle measuring system is so expensive for purchasing and complicated, so it takes a lot of time and money to use. This study was conducted to develop the algorithm for evaluating hydrophilic performance through measuring the contact angle of water droplet automatically, and fabricate relatively simple measuring system using a low-cost monochrome camera and image processing. A constant amount of water was firstly allocated on a slide by a micropipette, and then the image of water droplet was captured by monochrome digital camera and sent to a computer. The image was binarized and then reduced noises by labeling. Finally, the contact angle of water droplet was computed by using three points (left, right, and top coordinates), simple linear mathematics, and trigonometric function. The experimental results demonstrated the accuracy and reproducibility of the developed system showing less deviations and deviation ratio.

Analysis of QRS-wave Using Wavelet Transform of Electrocardiogram (웨이블릿 변환을 이용한 심전도의 QRS파 신호 분석)

  • Choi, Chang-Hyun;Kim, Yong-Joo;Kim, Tae-Hyeong;Ahn, Yong-Hee;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.317-325
    • /
    • 2008
  • The electrocardiogram (ECG) measurement system consists of I/O interface to input the ECG signals from two electrodes, FPGA (Field programmable gate arrays) module to process the signal conditioning, and real time module to control the system. The algorithms based on wavelet transform were developed to remove the noise of the ECG signals and to determine the QRS-waves. Triangular wave tests were conducted to determine the optimal factors of the wavelet filter by analyzing the SNRs (signal to noise ratios) and RMSEs (root mean square errors). The hybrid rule, soft method, and symlets of order 5 were selected as thresholding rule, thresholding method, and mother wavelet, respectively. The developed wavelet filter showed good performance to remove the noise of the triangular waves with 10.98 dB of SNR and 0.140 mV of RMSE. The ECG signals from a total of 6 subjects were measured at different measuring postures such as lying, sitting, and standing. The durations of QRS-waves, the amplitudes of R-waves, the intervals of RR-waves were analyzed by using the finite impulse response (FIR) filter and the developed wavelet filter. The wavelet filter showed good performance to determine the features of QRS-waves, but the FIR filter had some problems to detect the peaks of Q and S waves. The measuring postures affected accuracy and precision of the ECG signals. The noises of the ECG signals were increased due to the movement of the subject during measurement. The results showed that the wavelet filter was a useful tool to remove the noise of the ECG signals and to determine the features of the QRS-waves.

Design and Analysis of a Control System for Variable-Rate Application of Granular Fertilizers (입제 비료 변량 살포 제어시스템의 분석 및 설계)

  • Kim Y.H.;Rhee J.Y.;Kim Y.J.;Yu J.H.;Ryu K.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.203-208
    • /
    • 2006
  • This study was conducted to improve the control performance of a current variable-rate controller for granular fertilizers. Simulation model was developed. Optimized proportional, integral and derivative gains were determined by simulation model using 2nd order PID gain learning algorithm, and these control gains were evaluated through the field tests. Important results of this study are as follows; 1. Principles of pre-existing variable-rate application of granular fertilizers were investigated. 2. Simulation model of a PID controller that could simulate the control system was developed by using Matlab/Simulink program. The program was to determine PID control coefficients through the simulation model and 2nd order PID gain learning algorithm. 3. PID control coefficients obtained from the simulation were applied to the developed model. When the step input was given, Maximum overshoot were 1.96%, rise time were 0.05 sec, settling time were 0.06 sec and steady state error were 0.21 % respectively. 4. The simulation model was verified through field tests. The errors of maximum overshoot were 10%, rise time were 0.11 sec, settling time were 0.40 sec and steady state error were 8% because of loads and noises. Rise time was decreased to one third of that of the pre-existing system. 5. If the speed of a fertilizing machine is $0.3{\sim}0.6\;m/s$ and the maximum rotation speed of a discharging roller is 64 rpm, rise time would be 0.26 sec and fertilizing machine would cover the distance of $0.07{\sim}0.15\;m$ with settling time of 0.4 sec, fertilizing machine would cover the distance of $0.12{\sim}0.24\;m$.