• 제목/요약/키워드: Machined surface implant

검색결과 101건 처리시간 0.035초

타이타늄 임프란트 주위 골유착 관여 유전자의 발현: BMP2, BMP4 (EXPRESSION OF OSSEOINTEGRATION-RELATED GENES AROUND TITANIUM IMPLANT: BMP2, BMP4)

  • 심정환;지유진;송현철
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권4호
    • /
    • pp.307-314
    • /
    • 2005
  • After dental implant are planted into their bony site among the various growth factors associated with bone formation. BMP is expressed in the bone surrounding the implant fixture. By taking a close look at BMP2, BMP4 which are growth factors that take put in bone formation, its histologic features and radiographic bone healing patterns we would like to examine the mechanism of osseointegration. We randomly used 8 male and female house rabbit amd used diameter 5 mm height spiral shaped implants(Ostem, Korea) for animal use handled as a resorbable blast machined(RBM) surface and machined surface. 2group were formed and each group had RBM surface and machined surface implant or a simple bone cavity. After 3, 7, 14 and 28 days post surgery 2 objects were sacrificed from each group and histologic specimens were acquired. RT-PCR analysis was conducted and after H&E staining the extent of osseointegration was measured applying a histologic feature and histomorphometric analysis program. Quanitity one -4.41(Bio-Rad, USA) was used after scanning the PCR product image of the growth factors manifested in each group. According to the histomorphometric features the RBM, Machined surface group showed increased contact between bone and implant surface at 3, 7, 14 and 28 days after surgery. The BMP2 level increased in both experiment groups but remained unchanged in the contrast group. BMP4 levels stayed steady after the early post implantation period for RBM but showed decreased in the machined surface group and contrast group. The amount of contact between bone and implant surface increased with the passage of time. BMP2, BMP4 were expressed in both experimental group and contrast group. These growth factors play a role in osseointegration of implant.

RBM surface 임플란트의 골형성에 대한 EPMA 분석 (EPMA analysis of bone formation around RBM surface implant)

  • 정환종;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.503-510
    • /
    • 2008
  • Purpose: To evaluate bone formation on the implant surface between machined fixture and RBM surface fixture through analyzing of distribution and concentration of Ca and P by EPMA. Material and Methods: Fixtures had divided in 2 group: Machined(Group I), RBM (Group II). Total 4 fixtures were implanted on rabbit which sacrificed on 2 week and 4 week for the histological specimens. By these specimens EPMA value were measured, compared and analysed by each group to figure out the evidence of clinical use of RBM implant. Result: After 2 weeks and 4 weeks, it was analyzed that bone formation area, distribution and concentration of Ca and P by EPMA. In distribution and concentration of P Group II was higher than Group I, but there were no statistical significances. In new bone formation area, Group II was more higher than Group I with statistically significances. Both of group, after 4 weeks area is little bit higher than after 2 weeks area but there is no statistically significances. Conclusion: RBM implant was better than machined implant on the early bone formation.

토끼 경골에서 치과용 임프란트의 이중 산부식 및 양극 산화 표면처리에 따른 조직계측학적 연구 (HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH DOUBLE ACID-ETCHED AND ANODIC OXIDIZED SURFACE IN THE RABBIT TIBIA)

  • 한예숙;김일규;장금수;박태환;전원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.434-444
    • /
    • 2006
  • This study was performed to evaluate the effects of three different implant surface treatments to the bone formation during osseous healing period under unloading conditions. Machined, double-acid etched and anodic oxidized implants were inserted into tibia of 3.0 - 3.5 kg NZ white male rabbits and 2 animals of each group were sacrificed at 2, 4 and 8 weeks. The specimens containing implant was dehydrated and embedded into hard methylmethacrylate plastic. After grinding to $50{\mu}m$, the specimens were stained with Villanueva bone stain. From each specimen, histomorphometric evaluation and the bone implant contact rate were analysed with optical microscope. The results were as follows; 1. In the scanning electronic microscopic examination, machined surface implant had several shallow and paralleled scratches on plain surface, double acid-etched implant had lots of minute wrinkles, rough valley and also irregularly located craters that looked like waves, anodic oxidized surface implant had porosity that minute holes were wholly distributed on the surface. 2. After 2 weeks of implantation, the percentages of bone-to-implant contact in the machined implant, double acid-etched implant and anodic oxidized implant were 26.85%, 62.64% and 59.82%, after 4 weeks of implantation they were 64.29%, 77.85% and 75.23%, and after 8 weeks they were 82.66%, 85.34% and 86.39%. 3. After 2 weeks of implantation, the percentages of bone area between threads in the machined implant, double acid-etched implant and anodic oxidized implant were 21.55%, 42.81%, and 40.33%, after 4 weeks of implantation they were 49.32%, 62.60% and 75.56%, and after 8 weeks they were 71.62%, 87.73% and 83.94%. In summary, percentages of implant surface contacted to bone trabeculae and bone formation area inside threads in double acid-etched implants and anodic oxidized implants were greater than machined implants in early healing stage. These results suggest that double acid-etched and anodic oxidized surface implants could reduce the healing period for osseointegration and may enable to do early function.

타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구 (Wettability of titanium implants depending upon surface properties)

  • 한영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.12-20
    • /
    • 2009
  • 연구목적: 임플란트가 식립되어질 때 매식체는 조직액과 접촉하게 된다. 임플란트의 조직액 흡착은 표면처리에 따라 다양하게 나타난다. 이 때 임플란트 시편의 표면 거칠기와 젖음성과의 상관관계를 분석하고자 하였다. 연구재료 및 방법: 표면 거칠기와 젖음성의 상관관계를 측정하기 위해 네 종류의 임플란트 시편을 각각 5종류 만들었다. 각각의 그룹은 그룹 A: Machined Surface, 그룹 B: Anodized surface, 그룹 C: RBM (HA blasting) surface, 그룹 D: CMP (calcium methaphosphate) coating surface이다. 연구결과: 1. 표면의 거칠기는 RBM, CMP, Anodized, Machined 그룹 순서로 거칠었다. RBM과 CMP는 통계적으로 유의차가 없었다 (P<.05). 2. 젖음성은 Anodized, RBM, CMP, Machined 그룹 순서로 높았다. CMP와 Machined는 통계적으로 유의차가 없었다 (P<.05). 3. 표면 거칠기와 젖음성과의 상관관계는 없었다.

임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구 (ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS)

  • 김용재;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

토끼 경골에서 치과용 임프란트의 RBM 및 SLA 표면처리에 따른 조직계측학적 연구 (HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH RBM AND SLA SURFACE IN THE RABBIT TIBIA)

  • 송국현;김일규;장금수;김규남;최진웅
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.514-523
    • /
    • 2006
  • The purpose of the present study was to evaluate the effects of several implant surface treatments to the bone formation, by placing Machined implants, 75${\mu}m$ Calcium phosphate-blasted implants and $Al_2O_3$-blasted and acid-etched implants in rabbit tibia through histomorphometric study. Two animals of each group were sacrificed at 2, 4, 8 weeks. The specimens containing the implants were dehydrated and embedded into hard methylmethacrylate plastic. Thereafter, the sections were ground to 50${\mu}m$. The specimens were stained with Villanueva bone stain for a light microscopic study. The results were as follows; 1. When the surface roughness of three different implants was measured by Surfcorder, the Ra of the Machined group, the RBM group and the SLA group was 0.16${\mu}m$, 0.44${\mu}m$, and 1.08${\mu}m$. 2. When examining the surfaces of the implants in the scanning microscope, Machined implant has the smooth surface with a few scratches, RBM implant has the rough surface with curled ridges and valleys, and SLA implant has the rough surface structures such as sharp protruding parts and micropits measuring 1-2${\mu}m$ in diameter. 3. After 2 weeks of implantation, the percentage of bone-to-implant contact of the Machined group, the RBM group and the SLA group was 26.86%, 35.40% and 45.99%. However, its differences between each group decreased during the healing periods. 4. After 2 weeks of implantation, the percentage of bone area inside the threads of the Machined group, the RBM group and the SLA group were 21.55%, 30.43% and 41.18%. However, its difference of bone area between machined group and surface treatment groups was maintained but the difference within the surface treatment groups decreased during the healing periods. In summary, the amount of bone formation in RBM and SLA group was greater than Machined group in early healing stage. These results suggest that RBM and SLA implants can reduce the healing period for osseointegration and may be suitable for early function.

Machined 임플란트와 RBM surface 임플란트의 비교 연구 (A compare research of machined implant and RBM surface implant)

  • 유임수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.467-474
    • /
    • 2008
  • Purpose: To evaluate RBM surface implant which has its good character like that good initial stability, early bone formation. Material and Methods: In this study fixures have divided in 2 group: Machined(Group I), RBM(Group II). Total 10 fixtures were implanted on rabbit which sacrificed on week 2 and week 4 for the histological specimens. By these specimens polarized microscopic view, micro CT view, ISQ value were measured, compared and analysed by each group to figure out the evidence that clinical use of RBM implant. Result: ISQ value had no significance differences between 2 groups, However in each group 4, 8 weeks had higher ISQ value than 2 weeks. In polarized microscope, calcification level was following: Group II, Group I. In micro CT, formation of cancellous bone level was following: Group II, Group I. Conclusion: RBM implant was the most excellent on the early bone formation and good initial stability.

Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구 (Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants)

  • 강현주;양재호
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.122-127
    • /
    • 2010
  • 연구목적: 본 연구는 machined 임플란트와 골유도능이 있는 calcium phosphate를 electron-beam deposition으로 coating처리한 임플란트의 골/임플란트 접촉률을 조직형태계측학적으로 비교하는 것이다. 연구 재료 및 방법:여섯 마리의 수컷 New Zealand white rabbit과직경3.3 mm, 길이 5 mm의 임플란트 24개를 준비하였다. Machined 임플란트 (대조군)와 calcium phosphate coated 임플란트(실험군)를 좌, 우 경골에 2개씩 총 4개를 식립하고 임플란트 주위에 부하가 가해지지 않도록 하여 3주, 6주의 치유기간을 두었다. 식립 3주와 6주후, 각각 3마리의 토끼를 희생하여 조직시편을 제작하였다. 제작된 시편을 광학현미경 하에서 골/임플란트 접촉률 (BIC ratio)을 계산하고 paired t-test로 두 군을 비교하였다. 결과:골/임플란트 접촉률은 임플란트 식립 3주후, 대조군에서 평균과 표준편차는$44.1{\pm}16.5%$ 이었고 실험군은 $70.8{\pm}18.9%$로 실험군이 통계적으로 유의하게 높았다 (P= 0.0264). 6주후의경우, machined 임플란트는 $78.6{\pm}15.1%$, calcium phosphate coated 임플란트는 $79.0{\pm}26.0%$로 두 군 간 통계적으로 유의한 차이는 없었다. 결론: Calcium phosphate coated 임플란트는 machined 티타늄 임플란트에 비해 빠른 초기 골반응을 나타냈다. 그러므로, 임상적으로 calcium phosphate coated 임플란트를 사용했을 때, 수술 후 치유 기간을 단축하여 조기 부하가 가능할 것으로 사료된다.

처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향 (THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS)

  • 양성욱;임헌송;조인호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

구연산의 적용시간에 따른 임플란트 표면변화에 대한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of the Effects of Citric Acid on the Change of Implant Surface According to Application Time)

  • 송우석;권영혁;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.697-709
    • /
    • 2002
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, titanium plasma-sprayed surface, and sand-blasted, large grit, acid etched surface were utilized. Implant surface was rubbed with pH 1 citric acid for $\frac{1}{2}$ min., 1 min., 1 $\frac{1}{2}$ min., 2 min., and 3min, respeaively in the test group and implant surface was not treated in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In titanium plasma-sprayed surfaces, round or amorphous particles were deposited irregularly. The irregularity of titanium plasma-sprayed surfaces conditioned with pH 1 citric acid was lessened and the cracks were increased relative to the application time of pH 1 citric acid. 3. Sand-blasted, large grit, acid etched surfaces showed the macro/micro double roughness. The application of pH 1 citric acid didn't change the characteristics of the sand-blasted, large grit, acid etched surfaces. In conclusion, the application of pH 1 citric acid to titanium plasma-sprayed surface is improper. And pure titanium machined surface implants and sand-blasted, large grit, acid etched surface implants can he treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.