• Title/Summary/Keyword: Mach-Zehnder 광섬유 간섭계

Search Result 47, Processing Time 0.028 seconds

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

Mechanically induced Mach-Zehnder interferometers based on long-period fiber grating pair (기계적으로 구현된 장주기 광섬유 격자 Mach-Zehnder 간섭계)

  • 장현수;조준용;이경식
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.365-368
    • /
    • 2003
  • We have demonstrated mechanically induced Mach-Zehnder interferometers (MZI) based on a long-period fiber grating pair. The transmission spectra, the interference fringes, and the fringe spacing of the long-period fiber grating pairs have also been investigated experimently and analytically. The fringe spacings of the fabricated LPG pairs agree well with the theoretical results.

Sensitive Fiber-Optic Mach-Zehnder Interfermeter for the Detection of Low Frequency Magnetic Field (미소 저주파 자기장 측정을 위한 Mach-Zehnder 형 광섬유 간섭계 쎈서의 특성조사)

  • 안준태
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.109-109
    • /
    • 1991
  • 자기변형 효과가 큰 Metallic glass 2605SC에 20cm의 광섬유를 붙여서 교류 자기장 측정을 위한 Mach-Zehnder형 광섬유 간섭계를 구성하였다. 능동 위상 추적 방법을 사용하여 간섭계의 위상차를 최대 측정감도를 갖는 $\pi$/2로 고정시킴으로써 온도 및 진동등의 영향에 의한 신호소멸 현상을 해결하였다. 0.2~2.0 KHz에서 주파수특성, dc bias의 영향 그리고 교류 자기장과 간섭계 출력 사이의 선형성을 조사하였다.

  • PDF

Fiber-Optic Accelerometer by Mach-Zehnder Interferometer (Mach-Zehnder 간섭계를 이용한 광섬유 가속도기)

  • 이기완
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.10
    • /
    • pp.1092-1099
    • /
    • 1992
  • In this paper, a sensitivity of the gravity acceleration $(0{\sim}1G)$ for a fiber-optic accelerometer is demonstrated. A single mode optical fiber Mach-Zehnder interferometer was used to detect the change in optical path length produced by the strain in the fiber from probe mass about 1 gram. The phase conversion gain of the piezoelectric cylinder in the reference arm with this system measures 0.88rad./v.

  • PDF

The Fabrications of Fiber Optical Mach-Zehnder Interferometer Sensor Using Side Polished Fiber (측면 연마된 광섬유를 이용한 광섬유형 마흐-젠더 간섭계 센서 제작)

  • Kim, Jun-Hyong;Shin, Eun-Soo;Kim, Kwang-Taek;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.400-401
    • /
    • 2006
  • 광-바이오센서로 이용하기 위해 광섬유 형태의 마흐-젠더 간섭계와 측면 연마된 광섬유를 결합한 구조를 제안하였고, 이를 제작 및 특성 평가하였다. 마흐-젠더 간섭계 구성은 1310nm와 1550nm 파장에서 광 파워 분기비가 50:50인 $2{\times}2$ 광커플러 2개를 제작하여 구성하였으며, 센서부로는 측면 연마한 광섬유를 이용하였다. 제작된 광섬유 형태의 마흐-젠더 간섭계 센서의 센서부 표면에 다양한 굴절률 용액을 이용하여 광학적 특성을 평가하였다.

  • PDF

Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 이상훈;심승환;이광식;김달우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • It is well known that a partial-discharge(PD) in insulation oil is the source of various physical and chemical phenomena, such as heat, light, gas, chemical transformation, electric current, electromagnetic radiation and ultrasonics. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Ultrasonic-wave detection is a useful method for the diagnosis of the transformer-insulation condition. Conventionally, ulyrasonic waves are detected by Piezo-electric transducer, but we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

Intrusion Sensor Using Fiber-Optic Mach-Zehnder Interferometer (광섬유 마하젠더 간섭계를 이용한 침입자 감지 센서)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 2006
  • For the intruder detection, a buried fiber-optic sensor based on fiber-optic Mach-Zehnder interferometer is demonstrated. We buried the sensor arm in a styrene board and exerted pressure on it. The pressure-induced deformation speed has almost linear relationship with the output frequencies of the interference signals, and about 4.25 Hz frequency change per 0.01m/s was obtained. Also it has been shown that the amplitude of frequency component increases according to the weight of mass.

The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer (Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사)

  • Cho, Seung-Il;Kim, Sung-Boo;Lee, Jong-Kyu;Lee, Yong-Bong;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.

FBG Sensor Demodulation Using a Double-Pass Mach-Zhender Interferometer (더블패스 마하젠더 간섭계를 이용한 광섬유 격자 센서의 파장복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • A wavelength-demodulation algorithm for FBG sensor is proposed by using a double-pass Mach-Zehnder interferometer. Zero-crossing points of double-passed interference signal are used to trigger the accurate $90^{\circ}C$ phase difference positions in the sensor signal, which is an essential condition in the subsequent arctangent and phase unwrapping signal processing. With the proposed method, we could efficiently measure various measurands, such as dynamic-, static-strain, and temperature, and ${\sim}8pm$ of wavelength resolution was obtained.