• Title/Summary/Keyword: Mach-Zehnder

Search Result 287, Processing Time 0.027 seconds

Linear interrogation of fiber Bragg grating sensor array using time-delayed quadrature sampling technique (시간지연 샘플링을 이용한 광섬유 격자 센서어레이의 선형 복조)

  • 김종섭;송민호
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2004
  • A fiber laser of which wavelength was scanned by an intra-cavity FP (Fabry-Perot) filter was used to interrogate a fiber Bragg grating strain sensor array. We calculated the wavelength variation of the fiber laser using quadrature signal processing with an unbalanced M/Z (Mach-Zehnder) interferometer and time-delayed sampling technique. The calculated wavelengths are mapped to corresponding temporal reflection peaks from the sensor array, which enables more accurate and stable interrogation without the problems caused by the FP filter's nonlinear characteristics. Wavelength resolution of ∼20 pm was obtained in our experimental setup, which could have been greatly enhanced with faster phase modulation.

Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.380-385
    • /
    • 2011
  • Common-path interferometers are widely used for endoscopic optical coherence tomography (OCT) because an arbitrary arm length can be chosen for the endoscopic imaging probe. However, the scheme suffers from the limited range of the sample position distance from the end of the imaging probe because the position between the reference reflector and the sample is limited by the optical path-length difference (OPD) to induce an interference signal. In this study, we developed a novel method for compensating the arbitrary sample position in common-path swept-source OCT by adding an extra Mach-Zehnder interferometer in the post-path of the interfered optical signal. Theoretical analysis and an experimental demonstration of imaging depth tuning for the flexible sample position of an endoscopic OCT image are discussed. After post-tuning of sample position distance, the positioning limitation between the reference reflector and the sample can be solved for various sample positions over a range of 26 mm for the cross-sectional images of a fish eye sample.

Thermal Characteristics of an All Optical Add/Drop Multiplexer Using MZI and Fiber Bragg Gratings Filter (광섬유 브래그 격자 필터와 MZI를 이용한 전광 다중화기의 온도 특성)

  • Son, Yong-Hwan;Won, Yong-Yuk;Kim, Jae-Wook;Jung, Jin-Ho;Han, Sang-Kook
    • Journal of IKEEE
    • /
    • v.12 no.1
    • /
    • pp.43-50
    • /
    • 2008
  • In this paper, the output and temperature characteristics for an optical signal of the fiber bragg grating have been considered. Also, output characteristics which depend on the temperature changes have been investigated for an all-optic add/drop multiplexer based on the fiber bragg grating and Mach-Zehnder interferometer. From the obtained results, they show that the center wavelength of output spectrum shifts approximately 0.01230 nm/$^{\circ}C$ within a temperature range $-30^{\circ}C{\sim}90^{\circ}C$.

  • PDF

Two-Dimensional Free Convection in a Rectangular Enclosure Composed of a Hot Wall and Partially Cold Side Wall (아래면이 고온이고 옆면의 일부가 저온인 4각형 밀폐공간에서의 2차원 자연대류에 관한 연구)

  • 이택식;고상근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.213-221
    • /
    • 1985
  • Two dimensional laminar natural convection in a rectangular enclousure composed of a hot bottom wall, a partially cold side wall and insulated walls except the above walls was studied by numerical analysis and also by esperiments. In the experiments, the temperature distributions in the enclosure and Nusselt number distribution along the hot and cold walls were obtained by the use of Mach-Zehnder interferometer. At first, numerical analysis with the boundary conditions of the experimental apparatus was performed and the comparison of the results of the numerical and the experimental results validated the numerical model good ennough. Heat transfer characteristics were investigated by applying the verified numerical model with the parameters, i.e. Grashof number, aspect ratio, position of cold plate and insulation condition. The results showed the optimal conditions of temperature distribution and the position of cold wall, and the characteristics of insulation materials.

The Fabrication of Microlenses by Photoresist Melting Method (Photoresist 용융법을 이용한 미세렌즈 행렬 제작)

  • 주영구;송현우;이용희;송석호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.298-303
    • /
    • 1994
  • Microlens arrays are fabricated by melting "islands" of thick photoresist on a glass substrate. Microlenses with diameters $25\mu\textrm{m}$, $50\mu\textrm{m}$, $100\mu\textrm{m}$are made. Their surface profiles are obtained by a scanning electron microscope and a mechanical surface profilometer. The wavefront of the microlenses is measured by phase-shifting techniques using a Mach-Zehnder-like configuration. Thereby wavefront errors, focal lengths. point spread functions are obtained. The microlens with the diameter of $100\mu\textrm{m}$ has focal length of $164\mu\textrm{m}$ and spot diameter is less than $5\mu\textrm{m}$..

  • PDF

All-Optical AND Gate Using XPM Wavelength Converter

  • Kim, Jae-Hun;Kang, Byoung-Kwon;Park, Yoon-Ho;Byun, Young-Tae;Lee, Seok;Woo, Deok-Ha;Kim, Sun-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.25-28
    • /
    • 2001
  • By using an XPM (Cross Phase Modulation) wavelength converter, an all-optical AND gate, which is one of six fundamental logic gates, has been demonstrated. The wavelengths for probe and pump signals are 1553.8 and 1545 nm, respectively. First, characteristics of the XPM wavelength converter have been studied. When both probe and pump signals are driven by high power, the output power of the XPM wavelength is high. Based on this fact and the experiment, the all-optical AND gate has been porved. Probe and pump signals are transformed to pulse signals by using Mach-Zehnder modulator, which is induced by a pulse generator. Square pulse signals that are similar to the format of NRZ signals have been generated. By coupling two pulse signals into the XPM wavelength converter, AND characteristics in substantiated.

Final Diffraction Patterns of the Beam Splitters used in the Soft XRay Interferometer by a He-Ne Laser

  • Oh, Chul-Han;Choi, Dae-Uk;Park, Sung-Jin;Howells, M.R.;Moller, E.J.
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.7-10
    • /
    • 2000
  • The soft x-ray(10nm-100nm) interferometer is a modified Mach-Zehnder type interferometer and it consists of two beam-splitters and four totally reflecting mirrors. The beam-splitters used here are 50% transmission and 50% reflection grating type. The diffraction patterns of beam splitters(1st B.S.) were investigated with a He-Ne laser. The diffraction patterns produced by the soft x-ray interferometer (2nd B.S.) were also investigated in intensities positions. The diffraction patterns of 20 degree grazing incidence on the beam splitters(1st B.S.) show a circular array of spots. Both the reflected and the transmitted beams show the same patterns but symmetric circles on the screen. The maximum intensity appears roughly when n is in the zeroth and odd orders and the suppressed peak(missing order) appears when n is in even orders. Intensities of 3 center fringes(n = 0, $\pm$1) are stronger than others. These results confirm the reduced grating equation and make agree with the intensity distribution function. It was found that the final patterns produced by the soft x-ray interferometer (2nd B.S.) consisted of fine fringes which were caused by two of three diffraction beams that were arrived at the second beam-splitter.

Characteristics of Underwater Sound Detection of the Fiber Optic Hydrophone Array (광섬유 하이드로폰 배열의 수중음향 감지특성 연구)

  • Lee, Jong-Kil
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.102-107
    • /
    • 1999
  • In this paper, to develop the fiber optic hydrophone for the use of low frequency applications, two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array was fabricated and their acoustic charateristics were investigated in the acoustic water tank. A fiber length of the order of 150m is wounded at the hollow cylinder type aluminum mandrel and the fundamental natural frequency of the mandrel maintained above 10kHz. An unbalanced interferometer (discrete Mach-Zehnder type) was used. Sound detection performance is tested in the underwater tank with 3kHz continuous sound source. Finally, it is shown that two channels TDM fiber-optic hydrophone array can detect 3kHz sound stably. This results can also applicable for the development of multi-channel fiber optic hydrophone array.

  • PDF

A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor (포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구)

  • Ma, Ji-Hoon;Kang, Won-Jong;Lim, Yun-Sok;Choi, Jae-Ok;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

Two-step Holographic Imaging Method based on Single-pixel Compressive Imaging

  • Li, Jun;Li, Yaqing;Wang, Yuping;Li, Ke;Li, Rong;Li, Jiaosheng;Pan, Yangyang
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.146-150
    • /
    • 2014
  • We propose an experimental holographic imaging scheme combining compressive sensing (CS) theory with digital holography in phase-shifting conditions. We use the Mach-Zehnder interferometer for hologram formation, and apply the compressive sensing (CS) approach to the holography acquisition process. Through projecting the hologram pattern into a digital micro-mirror device (DMD), finally we will acquire the compressive sensing measurements using a photodiode. After receiving the data of two holograms via conventional communication channel, we reconstruct the original object using certain signal recovery algorithms of CS theory and hologram reconstruction techniques, which demonstrated the feasibility of the proposed method.