• Title/Summary/Keyword: Mach Wave

Search Result 269, Processing Time 0.027 seconds

Mach-Zehnder Type $Ti:LiNbO_3$ Traveling-Wave Optical Modulator with m-Section Phase Reversal (m-section의 위상반전이 있는 Mach-Zehnder형 진행파 $Ti:LiNbO_3$ 광변조기)

  • Lee, Woo-Jin;Kim, Kyoung-Am;Kim, Woo-Kyung;Kim, Chang-Min
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.7
    • /
    • pp.26-36
    • /
    • 2002
  • Mach-Zehnder type traveling-wave optical modulators with 3-section and 5-section phase reversal were designed and fabricated on z-cut $LiNbO_3$ substrates. Optical waveguides were designed by means of the FDM(Finite Difference Method). Design of CPW traveling-wave electrodes were performed by the SOR(Successive Over Relaxation) in the active region and by the CMM(Conformal Mapping) in the input/output section. The optical response R(${\omega}$ calculated based on the measured S-parameters showed the bandwidth of 15GHz centered at 25GHz for the 3-section, and the bandwidth of 22GHz at 45GHz for the 5-section.

Effect of Nonequilibrium Condensation on the Oscillation of the Terminating Shock in a Transonic Airfoil Flow (천음속 익형 유동에 있어서 비평형 응축이 충격파 진동에 미치는 영향)

  • Kim, Jin-Soo;Lee, Sung-Jin;Alam, Miah Md. Ashraful;Kwon, Soon-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • In this study, to find the effect of nonequilibrium condensation on the oscillation of the terminating shock wave in transonic flows, an NACA0014 airfoil flow with nonequilibrium condensation is analyzed using the total variation diminishing (TVD) numerical scheme. Transonic free stream Mach numbers of 0.81-0.87 are tested with variations in the stagnation relative humidity. For the same free stream Mach number and attack angle of ${\alpha}=0^{\circ}$, an increase in the stagnation relative humidity attenuates the strength of the terminating shock and reduces the oscillation of the terminating shock wave. Furthermore, for the same stagnation relative humidity, the larger the free stream Mach number becomes, the shorter the period of the oscillation shock wave is. The excursion distance of the oscillation shock increases with the free stream Mach numbers for the same stagnation relative humidity. Finally, it is found that for the same shock location, the strength of the oscillating shock facing upstream is stronger than that facing downstream.

Study of the Impulse Wave Impinging upon an Inclined Flat Plate (경사판에 충돌하는 펄스파에 관한 연구)

  • Kweon, Y.H.;Lee, D.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.438-443
    • /
    • 2001
  • Plate impingement of the impulse wave discharged from the open end of a duct is numerically investigated using a CFD method. Harten-Yee Total Variation Diminishing method is used to solve the unsteady, compressible flow governing equations. The Mach number, the flat plate inclination and the distance between the duct exit and inclined flat plate are changed to investigate their effects on the impinging flow field. The impulse wave impingement on the inclined flat plate depends on Mach number $M_s$ and the plate inclination $\psi$. The pressure distributions on the inclined flat plate show that for a small r/D, the peak pressure at the center of an inclined flat plate decreases with an increase in the plate inclination $\psi$ in the range of $\psi$ from $45^{\circ}$ to $60^{\circ}$ but for a large r/D, the peak pressure decreases with an increase in $\psi$ in the range of $\psi$ from $75^{\circ}$ to $90^{\circ}$. It is also found that for all of r/D, the peak pressure at the center of an inclined flat plate has a maximum value in $\psi=90^{\circ}$.

  • PDF

Study of the Shock Structure of Supersonic, Dual, Coaxial, Jets (초음속 이중 동축 제트유동에서 발생하는 충격파 구조에 관한 연구)

  • Lee, K.H.;Lee, J.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.417-422
    • /
    • 2001
  • The shock structure of supersonic, dual, coaxial jet is experimentally investigated. Eight different kinds of coaxial, dual nozzles are employed to observe the major features of the near field shock structure of the supersonic, coaxial, dual jets. Four convergent-divergent supersonic nozzles having the Mach number of 2.0 and 3.0, and are used to compare the coaxial jet flows discharging from two sonic nozzles. The primary pressure ratio is changed in the range between 4.0 and 10.0 and the assistant jet pressure ratio from 1.0 to 4.0. The results obtained show that the impinging angle, nozzle geometry and pressure ratio significantly affect the near field shock structure, Mach disk location and Mach disk diameter. The annular shock system is found depending the assistant and primary jet pressure ratios.

  • PDF

Study on the Affects of Mounting Axisymmetric Inlet to Airframe

  • Ando, Yohei;Matsuo, Akiko;Kojima, Takayuki;Maru, Yusuke;Sato, Tetsuya
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.699-702
    • /
    • 2004
  • In this study, the affect of mounting axisymmetrical supersonic inlet to airfoil, which has 65 degree swept angle was numerically investigated. The parameter for this calculation are tree stream Mach number M=2.0 and 2.5, the distance between inlet spike and airfoil lower surface $L_{sw}$/$R_{cowl}$ = 1.21-1.54 and angle of attack to the airfoil 0-4. The mass capture ratio improved 3points in M=2.0 condition and 1points in M=2.5 while the mass capture ratio without airfoil surface was 57% and 71 % for each case. These are the result from increase of density and change of velocity deflection by the shock wave structure formed between inlet and airfoil surface. On the other hand, the distortion of Mach number at cowl lip plane increased by 13% in M=2.0, 3% in M=2.5 condition. The effects of the angle attack on the mass capture ratio is greater than that of the shock wave interaction between inlet and cowl, but the effects to the distortion is smaller in the range of this calculation condition. In the condition of M=2.0 with 4 degrees of angle of attack, inlet distortion of Mach number is mainly caused by the affects of the shock wave interaction between inlet and airfoil surface, while the largest angle of the velocity vector in the radial direction at cowl lip plane is caused by the affect of angle of attack. This large velocity vector made the flow inside the cowl subsonic and caused spillage, which interfere with the boundary layer of airfoil surface.

  • PDF

Effects of Nonequilibrium Condensation on an Oblique Shock Wave in a Supersonic Nozzle of Constant Expansion Rate (팽창률이 일정한 초음속 노즐흐름에 있어서 비평형 응축이 경사충격파에 미치는 영향)

  • 강창수;권순범;김병지;홍종우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1311-1319
    • /
    • 1990
  • For the purpose of preventing the flow undulation in the cascade of steam turbine, the blades are made into a constant expansion rate in static pressure. And the flow in those cascades is transonic or supersonic in the range of 0.7-2.0 in Mach number. As a consequence, an oblique shock wave, known as inner or outer edge shock wave, arises in the flow of cascades. Especially when the steam in cascades is in a state of high wetness, nonequilibrium condensation and condensation shock wave occur, and they give rise to an interference with oblique shock wave. In the present study the case of expansion of moist air through a supersonic nozzle of constant expansion rate, which behaves similar to that of wet steam, was adopted. The effect of nonequilibrium condensation on the oblique shock wave generated by placing the wedge into the supersonic part of the nozzle was investigated. Furthermore, the relationship between nonequilibrium condensation zone and incident point of the oblique shock wave, oblique shock wave angle, the variations of angles of incident and reflected shock waves due to the variation of initial stagnation supersaturation and the relationship between the height of Mach stem and initial stagnation supersaturation are discussed.

Plume Structure Analysis of an Axisymmetric Supersonic Micro-nozzle at the Various Pressure Ratios (압력비가 변할 때 축대칭 초음속 노즐의 플룸 구조 해석)

  • Kwon, Soon-Duk;Kim, Sung-Cho;Kim, Jeong-Soo;Choi, Jong-Wook;Kim, Yong-Sseok
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2862-2867
    • /
    • 2007
  • The steady non-reacted compressible flow field in a symmetric micro-thruster, which is used for the accurate attitude control of a satellite, is analyzed varying the nozzle pressure ratio (NPR) to investigate the plume characteristics. The nozzle throat diameter is 0.06 inch and the area ratio is 56. The recirculation region is found just behind the normal shock at the several NPRs due to the locally adverse pressure gradient along the nozzle centerline when the environmental pressure is atmospheric. This phenomenon, the cause of flow loss, is similar to the flow behind a blunt body. As NPR increases the location of Mach disk, characteristics of the normal shock, moves downstream and its strength increases. The Mach number distribution appears in a wave-type patter after the normal shock because oblique shocks are reflected on the shock boundaries especially when NPRs are very high.

  • PDF

Fabrication and Characterization of PLC-based Mach-Zehnder Interferometer Sensor (PLC-기반의 마흐-젠더 간섭계 센서 제작 및 특성 평가)

  • Kim, Jun-Hyong;Yang, Hoe-Yong;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.390-390
    • /
    • 2008
  • In this paper, we have designed and fabricated optical waveguides based on the Mach-Zehnder Interferometer (MZI) for application to sensor. The evanecent-wave sensor based on the MZI principle has sufficiently high sensitivity to measure the change of the refractive index on surface of a waveguide. The waveguides were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of MZI optical waveguides was performed by a conventional Planar Lightwave Circuit (PLC) fabrication process. The fabricated MZI optical waveguide device was measured. According to the measurement result, the insertion loss of MZI optical waveguide device was below 3.5 dB and the polarization dependent loss (PDL) was within 0.1dB. In addition, we analyzed optical properties of MZI sensor according to the refractive index change of the sensor arm.

  • PDF

Effects of Mach Number on the Control of Supersonic Cavity Pressure Oscillations (초음속 공동내부의 압력진동 제어에 미치는 기류 마하수의 영향)

  • Shin, Choon-Sik;Suryan, Abhilash;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.119-122
    • /
    • 2009
  • Numerical computations were carried out to analyze the effect of inlet Mach number and sub-cavity on the control of cavity-induced pressure oscillations in two-dimensional supersonic flow. A passive control method wherein a sub-cavity was introduced on the front wall of a square cavity was studied for Mach numbers 1.50, 1.83 and 2.50. The results showed that sub-cavity is effective in reducing the oscillations at different inlet Mach numbers. The resultant amount of attenuation of pressure oscillations depended on the inlet Mach number, length of the flat plate, and the depth of the sub-cavity used as an oscillation suppressor.

  • PDF

The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer (Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사)

  • Cho, Seung-Il;Kim, Sung-Boo;Lee, Jong-Kyu;Lee, Yong-Bong;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.