• Title/Summary/Keyword: M_CAM

Search Result 354, Processing Time 0.032 seconds

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

Performance Analysis of Variable Valve for Diesel Engine with Cam-in-Cam System (디젤엔진용 Cam-in-Cam시스템 적용 가변밸브 성능해석)

  • Jeong, S.C.;Park, J.M.;Kim, T.K.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.22 no.1
    • /
    • pp.22-28
    • /
    • 2017
  • In this study, the effects of intake valve closing timing by using Cam-in-Cam system on combustion and emission characteristics for diesel engine were investigated under GT-POWER simulation environment. As a result, it was found that volumetric efficiency and effective compression ratio were decreased as the intake valve closing(IVC) timing is retarded due to its backflow effect. Also, we found that in-cylinder pressure, heat release rate and NOx emission were decreased as IVC timing was retarded. These show that the LIVC(late intake valve closing) can be effective to control AFR and mixing rate in diffusion combustion of diesel engine.

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

A COMPARISON OF THE FIDELITY BETWEEN VARIOUS CORES FABRICATED WITH CAD/CAM SYSTEMS

  • Park, Sun-Hee;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.269-279
    • /
    • 2008
  • STATEMENT OF PROBLEM: Recently, various all-ceramic crowns fabricated with CAD/CAM systems have come into wide use in dental clinic. However, there are only few domestic studies on CAD/CAM restorations. PURPOSE: Purpose of this study was to compare the fidelity (absolute marginal discrepancy and internal gap) between various cores fabricated with different CAD/CAM systems (Procera system, Lava system, Cerec inLab system) and conventional metal cast core. MATERIALS AND METHODS: 10 cores per each system were fabricated. The absolute marginal discrepancies were measured using measuring microscope and digital counter. The internal gaps were calculated using a silicone paste. The results were statistically analyzed using the one-way ANOVA test and Tukey's HSD test. RESULTS: Within the limits of this study the results were as follows. 1. The absolute marginal discrepancies were $32.5{\pm}3.7\;{\mu}m$ for metal cast core, $72.2{\pm}7.0\;{\mu}m$ for Procera core, $40.8{\pm}5.4\;{\mu}m$ for Lava core, and $55.3{\pm}8.7\;{\mu}m$ for Cerec inLab core. The internal gaps were $38.4{\pm}5.7\;{\mu}m$ for metal cast core, $71.4{\pm}5.3\;{\mu}m$ for Procera core, $45.9{\pm}7.3\;{\mu}m$ for Lava core, and $51.8{\pm}6.2\;{\mu}m$ for Cerec inLab core. 2. The fidelity of metal cast core showed the smallest gaps, followed by Lava core, Cerec inLab core, and Procera core. CONCLUSION: The fidelities of 4 core groups were all within the clinically acceptable range ($120\;{\mu}m$).

MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM (CAD/CAM으로 제작한 코누스내관의 변연적합)

  • Kim In-Sup;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

A Study on the Design of Testable CAM using MTA Code (MTA 코드를 적용한 Testable CAM 설계에 관한 연구)

  • 정장원;박노경;문대철
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.48-55
    • /
    • 1998
  • In this work, the testable CAM(Content Addressable Memory) is designed to perform the test effectively by inserting the ECC(Error Checking Circuit) inside the CAM. The designed CAM has the circuit which is capable of testing the functional faults in read, write, and match operations. In general the test circuit inserted causes the increase of total circuit area, Thus this work, utilizes the new MTA code to reduce the overhead of an area of the built-in test circuit which has a conventional parallel comparator. The designed circuit was verified using the VHDL simulator and the layout was performed using the 0.8${\mu}{\textrm}{m}$ double metal CMOS process. About 30% reduction of a circuit area wad achieved in the proposed CAM using the XOR circuit

  • PDF

A Study on Photosynthesis and Nitrogen Assimilation in Cactus -Portulaca oleracea L.- (Cactus의 광합성과 질소동화작용에 관한 연구 - 한국산 쇠비름(Portulaca oleracea L.) -)

  • 장남기;김희백
    • Asian Journal of Turfgrass Science
    • /
    • v.10 no.2
    • /
    • pp.125-142
    • /
    • 1996
  • Crassulacean acid metaholism (CAM) was investigated in leaves and stems of the succulent $C_4$dicot Portulaca oleracea L. Under 14-hour days, stem tissues showed much greater fluctuation of acidity than leaf tissues. But leaf and stem tissues showed almost same CAM-like pattern of acid fluctuation under 8-hour days. Stem tissues of R oleracea grown under the naturai environment showed high CAM activity, but no CAM activity was seen in leaves of those plants. In the naturally growing plants, the rapid acidification was seen in intact stems at dawn, but defoliated stems showed only a gradual increase. RuBP carlboxylase activity was very high at 2:00 P.M. in both leaves and stems. However, its activity at 1:00 A.M. and 5:30 AM. was hardly detected. particularly, activity of PEP carboxylase in leaves was very high in the early morning, though that in stem tissues was little. These results indicate that $CO_2$ passed through open stomata at dawn may be assimilated by PEP carboxylase in leaves, and then $C_4$ products move to stems. The levels of nitrate concentration and of nitrate reductase were higher in stems than in leaves. The levels were also higher in the light than in the dark. It would be suggested that considerable amount of nitrate absorbed from roots ho assimilated in stems, and nitrate transferred to leaves via stem tissues be reduced there. Key words: Portalaca oleracea, Cactus, Photosynthesis, Nitrogen assimilation, Crassulacean acid metabolism (CAM).

  • PDF