• Title/Summary/Keyword: MW Model

Search Result 387, Processing Time 0.026 seconds

Wind-induced responses and equivalent static wind loads of tower-blade coupled large wind turbine system

  • Ke, S.T.;Wang, T.G.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.485-505
    • /
    • 2014
  • This study aimed to develop an approach to accurately predict the wind models and wind effects of large wind turbines. The wind-induced vibration characteristics of a 5 MW tower-blade coupled wind turbine system have been investigated in this paper. First, the blade-tower integration model was established, which included blades, nacelle, tower and the base of the wind turbine system. The harmonic superposition method and modified blade element momentum theory were then applied to simulate the fluctuating wind field for the rotor blades and tower. Finally, wind-induced responses and equivalent static wind loads (ESWL) of the system were studied based on the modified consistent coupling method, which took into account coupling effects of resonant modes, cross terms of resonant and background responses. Furthermore, useful suggestions were proposed to instruct the wind resistance design of large wind turbines. Based on obtained results, it is shown from the obtained results that wind-induced responses and ESWL were characterized with complicated modal responses, multi-mode coupling effects, and multiple equivalent objectives. Compared with the background component, the resonant component made more contribution to wind-induced responses and equivalent static wind loads at the middle-upper part of the tower and blades, and cross terms between background and resonant components affected the total fluctuation responses, while the background responses were similar with the resonant responses at the bottom of tower.

Safety-Related Bus Voltage Variation during Large Induction Motor Start-up in 1400MW Light Water Reactor Type Nuclear Power Plant (1400MW급 경수로형 원자력발전소의 대용량 유도전동기 시동시 안전관련 모선 전압 변동)

  • Lee, Cheoung Joon;Kim, Chang Kook;Noh, Young Seok;Joo, Young Hwan
    • Plant Journal
    • /
    • v.12 no.4
    • /
    • pp.37-43
    • /
    • 2016
  • Power system which provides electricity to the accident mitigation load for nuclear power plant should be verified to maintain the proper voltage level under the various loading and source conditions. For this purpose, it was needed to collect the voltage data of safety related buses during operation of the Reactor Coolant Pump(RCP) motor and Component Cooling Water Pump(CCWP) motor, respectively, under the certain loading condition of the plant. The data (such as, voltage, current, power factor) collected from actual measurement were used to modify the existing ETAP model and then the reanalysis was conducted to simulate the testing conditions. Through these actual measurement and analysis, it ensures that the existing electrical system analysis including assumptions and methods was conducted properly. Finally, the voltage of safety related buses was not dropped below the acceptable level, and the discrepancy between two results was within the limit.

  • PDF

Three-D core multiphysics for simulating passively autonomous power maneuvering in soluble-boron-free SMR with helical steam generator

  • Abdelhameed, Ahmed Amin E.;Chaudri, Khurrum Saleem;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2699-2708
    • /
    • 2020
  • Helical-coil steam generator (HCSG) technology is a major design candidate for small modular reactors due to its compactness and capability to produce superheated steam with high generation efficiency. In this paper, we investigate the feasibility of the passively autonomous power maneuvering by coupling the 3-D transient multi-physics of a soluble-boron-free (SBF) core with a time-dependent HCSG model. The predictor corrector quasi-static method was used to reduce the cost of the transient 3-D neutronic solution. In the numerical system simulations, the feedwater flow rate to the secondary of the HCSGs is adjusted to extract the demanded power from the primary loop. This varies the coolant temperature at the inlet of the SBF core, which governs the passively autonomous power maneuvering due to the strongly negative coolant reactivity feedback. Here, we simulate a 100-50-100 load-follow operation with a 5%/minute power ramping speed to investigate the feasibility of the passively autonomous load-follow in a 450 MWth SBF PWR. In addition, the passively autonomous frequency control operation is investigated. The various system models are coupled, and they are solved by an in-house Fortran-95 code. The results of this work demonstrate constant steam temperature in the secondary side and limited variation of the primary coolant temperature. Meanwhile, the variations of the core axial shape index and the core power peaking are sufficiently small.

Performance of a 3D pendulum tuned mass damper in offshore wind turbines under multiple hazards and system variations

  • Sun, Chao;Jahangiri, Vahid;Sun, Hui
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.53-65
    • /
    • 2019
  • Misaligned wind-wave and seismic loading render offshore wind turbines suffering from excessive bi-directional vibration. However, most of existing research in this field focused on unidirectional vibration mitigation, which is insufficient for research and real application. Based on the authors' previous work (Sun and Jahangiri 2018), the present study uses a three dimensional pendulum tuned mass damper (3d-PTMD) to mitigate the nacelle structural response in the fore-aft and side-side directions under wind, wave and near-fault ground motions. An analytical model of the offshore wind turbine coupled with the 3d-PTMD is established wherein the interaction between the blades and the tower is modelled. Aerodynamic loading is computed using the Blade Element Momentum (BEM) method where the Prandtl's tip loss factor and the Glauert correction are considered. Wave loading is computed using Morison equation in collaboration with the strip theory. Performance of the 3d-PTMD is examined on a National Renewable Energy Lab (NREL) monopile 5 MW baseline wind turbine under misaligned wind-wave and near-fault ground motions. The robustness of the mitigation performance of the 3d-PTMD under system variations is studied. Dual linear TMDs are used for comparison. Research results show that the 3d-PTMD responds more rapidly and provides better mitigation of the bi-directional response caused by misaligned wind, wave and near-fault ground motions. Under system variations, the 3d-PTMD is found to be more robust than the dual linear TMDs to overcome the detuning effect. Moreover, the 3d-PTMD with a mass ratio of 2% can mitigate the short-term fatigue damage of the offshore wind turbine tower by up to 90%.

Economic Assessment on an Integrated system of Phosphoric Acid Fuel Cell and Organic Rankine Cycle (인산형 연료전지와 유기랭킨사이클 연계시스템에 대한 경제성 평가)

  • Kim, Deug Soo;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.43-49
    • /
    • 2022
  • In this study, the operational characteristics of the 7.48 MW fuel cell power plant consisting of 17 units of 440 kW Phosphoric Acid Fuel Cell (PAFC) in operation since its commercial operation in December 2017 were explained and the heat recovery process of the plat using Organic Rankine Cycle (ORC)was simulated. The fuel cell system performance improvement and economic assessment were analyzed by calculating the amount of heat recovery and electric power available when connecting a 125 kW XLT Model ORC for hot water heat sources with 105℃, 40.8 t/h. The result of the study shows that integrating the 125 kW ORC to PAFC power plant would improve generating efficiency by about 0.6% through annually 851,472 kWh of electricity produced by ORC, and fuel cell and ORC integrated systems were calculated to have a 0.35% higher Internal Return Ratio and more Net Present Value of 1,249 million KRW than not installing ORC despite installation costs.

  • PDF

Transient heat transfer and crust evolution during debris bed melting process in the hypothetical severe accident of HPR1000

  • Chao Lv;Gen Li;Jinchen Gao;Jinshi Wang;Junjie Yan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3017-3029
    • /
    • 2023
  • In the late in-vessel phase of a nuclear reactor severe accident, the internal heat transfer and crust evolution during the debris bed melting process have important effects on the thermal load distribution along the vessel wall, and further affect the reactor pressure vessel (RPV) failure mode and the state of melt during leakage. This study coupled the phase change model and large eddy simulation to investigate the variations of the temperature, melt liquid fraction, crust and heat flux distributions during the debris bed melting process in the hypothetical severe accident of HPR1000. The results indicated that the heat flow towards the vessel wall and upper surface were similar at the beginning stage of debris melting, but the upward heat flow increased significantly as the development of the molten pool. The maximum heat flux towards the vessel wall reached 0.4 MW/m2. The thickness of lower crust decreased as the debris melting. It was much thicker at the bottom region with the azimuthal angle below 20° and decreased rapidly at the azimuthal angle around 20-50°. The maximum and minimum thicknesses were 2 and 90 mm, respectively. By contrast, the distribution of upper crust was uniform and reached stable state much earlier than the lower crust, with the thickness of about 10 mm. Moreover, the sensitivity analysis of initial condition indicated that as the decrease of time interval from reactor scram to debris bed dried-out, the maximum debris temperature and melt fraction became larger, the lower crust thickness became thinner, but the upper crust had no significant change. The sensitivity analysis of in-vessel retention (IVR) strategies indicated that the passive and active external reactor vessel cooling (ERVC) had little effect on the internal heat transfer and crust evolution. In the case not considering the internal reactor vessel cooling (IRVC), the upper crust was not obvious.

Study on an open fuel cycle of IVG.1M research reactor operating with LEU-fuel

  • Ruslan А. Irkimbekov ;Artur S. Surayev ;Galina А. Vityuk ;Olzhas M. Zhanbolatov ;Zamanbek B. Kozhabaev;Sergey V. Bedenko ;Nima Ghal-Eh ;Alexander D. Vurim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1439-1447
    • /
    • 2023
  • The fuel cycle characteristics of the IVG.1M reactor were studied within the framework of the research reactor conversion program to modernize the IVG.1M reactor. Optimum use of the nuclear fuel and reactor was achieved through routine methods which included partial fuel reloading combined with scheduled maintenance operations. Since, the additional problem in planning the fuel cycle of the IVG.1M reactor was the poisoning of the beryllium parts of the core, reflector, and control system. An assessment of the residual power and composition of spent fuel is necessary for the selection and justification of the technology for its subsequent management. Computational studies were performed using the MCNP6.1 program and the neutronics model of the IVG.1M reactor. The proposed scheme of annual partial fuel reloading allows for maintaining a high reactor reactivity margin, stabilizing it within 2-4 βeff for 20 years, and achieving a burnup of 9.9-10.8 MW × day/kg U in the steady state mode of fuel reloading. Spent fuel immediately after unloading from the reactor can be placed in a transport packaging cask for shipping or safely stored in dry storage at the research reactor site.

A Study on the Global Motion Performance of Floater and Mooring Due to Arrangement of Detachable Mooring System (탈착형 계류시스템 배치에 따른 부유식 해양구조물의 운동 및 계류성능에 관한 연구)

  • Kangsu Lee;Hyun-Sung Kim;Byoung Wan Kim
    • Journal of Wind Energy
    • /
    • v.14 no.2
    • /
    • pp.26-33
    • /
    • 2023
  • In this study, the global response characteristics of floater and mooring for floating offshore wind turbine with a detachable mooring system are performed. Global motion and structural response result extracted from the coupled motion analysis of 10MW DTU floating offshore wind turbine with detachable mooring system modeled by high-order boundary element model and finite element mesh, were used to study the characteristics of tension on mooring lines subjected to three different types of ocean loads. Breaking limit of mooring line characterized by wind, current and wave load has a major effect on the distribution of mooring tension found in time domain analysis. Based on the numerical results of coupled motion analysis, governing equation for calculating the motion response of a floater under ocean loads, and excitation force and surge motion and tension respectively are presented using excursion curve. It is found that the response of floater is reliable and accurate for calculating the tension distributions along the mooring lines under complex loadings. This means that the minimun breaking limit of mooring system satisfied a design criteria at ultimate ocean environmental loading condtions.

Comparison of models for sound propagation of low frequency wind turbine noise (풍력발전기의 저주파 소음 전파 모델 비교)

  • SungSoo Jung;Taeho Park;ByungKwon Lee;JinHyeong Kim;TaeMuk Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.162-167
    • /
    • 2024
  • Low frequency noise emitted by wind turbines is one of the most noise complaints. In this study, the reliability of the models was examined by comparing the measured sound pressure levels with the predicted levels based on Denish model and commercial programs of the SounPLAN and the ENPro based on ISO 9613. As a result of applying it to representative 3 MW wind turbines, on lnad, the measured and the predicted values differed within a maximum of 5 dB in the frequency range of 12.5 Hz to 80 Hz. It may be due to the change in the acoustic power levels because the wind turbines have been in operation for more than 7 years. However, considering that the Boundary Element Method (BEM) predicted value, which is known to be the most accurate in the low frequency band, the predicted values are well matched within 2.5 dB, the models of this study are expected to be used as deviation within 3 dB.

Effects of Whey Protein Hydrolysates on Lipid Profiles and Appetite-Related Hormones in Rats Fed High Fat Diet (고지방식이를 섭취한 흰쥐에서 유청단백질 가수분해물의 섭취가 지질 농도 및 식욕 관련 호르몬에 미치는 영향)

  • Park, Jung-Yoon;Park, Mi-Na;Choi, You-Young;Yun, Sung-Seob;Chun, Ho-Nam;Lee, Yeon-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.428-436
    • /
    • 2008
  • This study was carried out to compare the effects of whey protein concentrate, its hydrolysates and macropeptide fractions obtained from papain treatment of whey protein on lipid levels and appetite-related hormones in obesity model rats induced by high fat diet. Four week-old male Sprague-Dawley rats were fed high fat (18% w/w) and low protein (10% w/w) diet for 4 weeks and then divided into four groups (n=8/group). Rats were fed high fat diets containing various nitrogen sources; 10% whey protein concentrate (10WPC), 25% whey protein concentrate (25WPC), 25% whey protein hydrolysates (25WH), and 25% whey macropeptide fractions (25WP, MW$\geq$10,000), respectively for 6 weeks. There were no significant differences in body weight gain and food intake among groups. A significant decrease of total lipid, triglyceride in serum was observed in 25WH and 25WP groups. Total lipid and triglyceride contents of the liver were significantly decreased in 25WPC, 25WH and 25WP groups compared with 10WPC group. However, in the liver, there were no differences in the contents of total lipid and triglyceride among 25WPC, 25WH and 25WP groups. The daily amounts of feces were significantly increased in 25WH and 25WP groups and the excretion of total lipid and triglyceride were significantly increased in 25WH group. Serum glucose and insulin concentration were significantly decreased in 25WH group. The concentration of serum ghrelin was significantly decreased in the 25WPC, 25WH and 25WP groups compared with 10WPC group. However, there was no significant difference in the concentration of serum leptin among groups. These results suggest that whey protein hydrolysates and macropeptide fractions may show beneficial effects on the lipid profile in serum and liver, appetite regulation and insulin resistance in obesity model rats induced by high fat diet.