A Study on Medical Waste Generation Analysis during Outbreak of Massive Infectious Diseases (대규모 감염병 발병에 따른 의료폐기물 발생량 예측에 관한 연구)

  • Sang-Min Kim;Jin-Kyu Park;In-Beom Ko;Byung-Sun Lee;Sang-Ryong Shin;Nam-Hoon Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.29-39
    • /
    • 2023
  • In this study, an analysis of medical waste generation characteristics was conducted, differentiating between ordinary situation and the outbreaks of massive infectious diseases. During ordinary situation, prediction models for medical waste quantities by type, general medical waste(G-MW), hazardous medical waste(H-MW), infectious medical waste(I-MW), were established through regression analysis, with all significance values (p) being <0.0001, indicating statistical significance. The determination coefficient(R2) values for prediction models of each category were analyzed as follows : I-MW(R2=0.9943) > G-MW(R2=0.9817) > H-MW(R2=0.9310). Additionally, factors such as GDP(G-MW), the number of medical institutions (H-MW), and the elderly population ratio(I-MW), utilized as influencing factors and consistent with previous literature, showed high correlations. The total MW generation, evaluated by combining each model, had an MAE of 2,615 and RMSE of 3,353. This indicated accuracy levels similar to the medical waste models of H-MW(2,491, 2,890) and I-MW(2,291, 3,267). Due to limitations in accurately estimating the quantity of medical waste during the rapid and outbreaks of massive infectious diseases, the generation unit of I-MW was derived to analyze its characteristics. During the early unstable stage of infectious disease outbreaks, the generation unit was 8.74 kg/capita·day, 2.69 kg/capita·day during the stable stage, and an average of 0.08 kg/capita·day during the reduction stage. Correlation analysis between generation unit of I-MW and lethality rates showed +0.99 in the unstable stage, +0.52 in the stable stage, and +0.96 in the reduction period, demonstrating a very high positive correlation of +0.95 or higher throughout the entire outbreaks of massive infectious diseases. The results derived from this study are expected to play a useful role in establishing an effective medical waste management system in the field of health care.

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River (낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성)

  • Hwang, Deok-Heung;Kim, Dong-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF

Interaction of magnetic water, silica fume and superplasticizer on fresh and hardened properties of concrete

  • Mazloom, Moosa;Miri, Sayed Mojtaba
    • Advances in concrete construction
    • /
    • v.5 no.2
    • /
    • pp.87-99
    • /
    • 2017
  • After passing through a magnetic field, the physical quality of water improves, and magnetic water (MW) is produced. There are many investigations on the effects of magnetic field on water that shows MW properties like saturation and memory effect. This study investigates the fresh and hardened properties of concrete mixed with MW, which contains silica fume (SF) and superplasticizer (SP). The test variables included the magnetic field intensity for producing MW (three kinds of water), SF content replaced cement (0 and 10 percent), water-to-cementitious materials ratio (W/CM=0.25, 0.35 and 0.45) and curing time (7, 28 and 90 days). The results of this study show that MW had a positive impact on the workability and compressive strength of concrete. By rising the intensity of the magnetic field which was used for producing MW, its positive influence on both workability and compressive strength improved. MW had greater positive impacts on samples containing SP that did not have SF. Moreover, the best compressive strength improvements of concrete achieved as W/CM ratio decreased.

Evaluating Efficiency of Coal Combustion Products (CCPs) and Polyacrylamide (PAM) for Mine Hazard Prevention and Revegetation in Coal Mine Area

  • Oh, Se Jin;Oh, Seung Min;Ok, Yong Sik;Kim, Sung Chul;Lee, Sang Hwan;Yang, Jae E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.525-532
    • /
    • 2014
  • Since mine wastes were merely dumped in the mine waste dump, they have produced acid mine drainage (AMD). Therefore, main objective of this study was to evaluate the effect of coal combustion products (CCPs) on heavy metal stabilization and detoxification for mine wastes. Total six treatments for incubation test were conducted depending on mixing method (completely mixing and layered). Also, lysimeter experiment was conducted to examine efficiency of polyacrylamide (PAM) on reduction of mine wastes erosion. Result of incubation test showed that concentrations of soluble aluminium (Al) and iron (Fe) in leachate decreased compared to control. The lowest soluble Al and Fe in leachate was observed in 50% mixed treatment (14.2 and $1.03mg\;kg^{-1}$ for Al and Fe respectively) compared to control treatment (253.0 for Al and $52.6mg\;kg^{-1}$ for Fe). The pH of mine wastes (MW) and leachate increased compared to control after mixing with CCPs and ordered as control (MW 6.4, leachate 6.3) < 10% (MW 7.7, leachate 7.1) < 20% (MW 9.0, leachate 7.8) < 30% (MW 9.5, leachate 8.3) < 40% (MW 9.9, leachate 8.5) < 50% (MW 10.5, leachate 8.6). Application of PAM, both in liquid and granular type, dramatically decreased the suspended solid (SS) concentration of CCPs treatments. Reduction of SS loss was ordered as MW70CR30L ($24.4mg\;L^{-1}$) > MW70CR30LPL ($6.7mg\;L^{-1}$) > NT ($3.1mg\;L^{-1}$) > MW70CR30M ($1.6mg\;L^{-1}$) > MW70CR30MPL ($1.1mg\;L^{-1}$) > MW70CR30PGM ($0.7mg\;L^{-1}$) > MW70CR30LPG ($0.5mg\;L^{-1}$) > MW70CR30MPG ($0.4mg\;L^{-1}$). Overall, application of CCPs can be environmental friendly and cost-effective way to remediate coal mine wastes contaminated with heavy metals. In addition, use of PAM could help to prevent the erosion coal mine wastes in mine waste disposal area.

Effect of Analytical Parameters of Gel Permeation Chromatography on Molecular Weight Measurements of Urea-Formaldehyde Resins

  • Jeong, Bora;Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.471-481
    • /
    • 2017
  • As the molecular weight (MW) of urea-formaldehyde (UF) resins had a great impact on their properties, this work was conducted to study effect of analytical parameters of gel permeation chromatography (GPC) on the MW measurement of UF resins. GPC parameters such as flow rate, column, detector temperature, and sample injection temperature were selected to compare number-average molecular weight (Mn), weight-average molecular weight (Mw), molecular weight distribution (MWD) and polydispersity index (PDI) of two UF resins with different viscosities. As expected, UF resin with higher viscosity resulted in greater Mn and Mw than those of low viscosity UF resin. When the flow rate increased, both Mn and Mw of UF resins decreased and MWD became narrower. By contrast, both Mn and Mw increased and MWD became wide when the column, detector, and sample injection temperature increased. The column, detector, and sample injection temperature of $50^{\circ}C$ at a flow rate of $0.5m{\ell}/min$ resulted in the highest MW and broadest MWD for the GPC analysis. These results suggest that the apparent molecular size or a hydrodynamic radius of UF resin molecules dissolved in the mobile phase affect to Mn, Mw and MWD.

In Vitro Antiviral Activity of Aqueous Extracts from Korean Medicinal Plants Against Influenza Virus Type A

  • Park, Kap-Joo;Lee, Hyung-Hoan
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.5
    • /
    • pp.924-929
    • /
    • 2005
  • Boiled-water extracts from 101 Korean medicinal plants were tested in vitro for their inhibitory activity against influenza virus type A by means of a modified hemagglutination inhibition test. Thirteen of the 101 extracts exhibited strong anti-influenza virus type A activity at concentrations of less than $780\;{\mu}g/ml$. Out of the above 13 extracts, MW-40 (Chaenomeles speciosa), MW-88 (Citrus junos), and MW-100 (Zingiber officinale) exhibited marked antiviral activity in the concentration range of $0.195\;{\mu}g/ml$ to 100 mg/ml, $0.0487\;{\mu}g/ml$ to 100 mg/ml, and $0.0487\;{\mu}g/ml$ to 100 mg/ml, respectively. The extracts MW-88 and MW-100 were not cytotoxic to red blood cells, whereas MW-40 showed very weak cytotoxicity in the concentration range of 50 mg/ml to 100 mg/ml. Therefore, the present results demonstrate that boiled water extracts of 2 Korean medicinal plants, MW-88 and MW-100, have strong anti-influenza virus type A activity and no cytotoxic effects, and they may inhibit attachment of the virus to the cell and may be used for prophylaxis.

High enthalpy supersonic plasma test facility and its applications

  • Seo, Jun-Ho;Choe, Seong-Man;Sin, Ui-Seop;Seo, Yong-Seok;Kim, Min-Ho;Choe, Chae-Hong;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.92-92
    • /
    • 2010
  • 전북대학교에서는 우리나라 최초로 0.4 및 2.4 MW 급 초음속 열플라즈마 시험 시설 구축사업을 진행하고 있으며, 이를 이용한 응용 분야 별 선행연구를 수행하고 있다. 구축 시험 시설의 핵심장치인 MW 급 대출력 초음속 열플라즈마 발생기로는 양극과 음극 사이에, 전기적으로 절연된 도넛 형태의 간극을 다수 삽입하여 아크 길이를 늘림으로써, 플라즈마 출력을 비례하여 높일 수 있는 Segmented 형 아크 직류 토치를 사용하고자 하며, 제작을 위해 설계 중인 토치는 0.4 및 2.4 MW 출력에 대해, 마하 2 이상의 초음속 유동에서 각각 13 및 20 MJ/kg 이상의 플라즈마 비엔탈피 구현을 목표로 하고 있다. 특히, 이와 같은 고엔탈피 초음속 유동의 달성은 0.4MW 급의 경우엔 공기유량 0.01 kg/s 이상에서, 2.4 MW 급의 경우엔 0.05 kg/s 이상에서 10Torr 이하의 진공과 투입된 MW 규모의 열량을 지속적으로 유지 및 제거할 수 있는 시설이 있어야 구현 가능하므로 이를 위한 건축과 지원시설 구축을 동시에 진행하고 있다. 본 발표에서는 0.4 MW 급 초음속 열플라즈마 시험 시설을 중심으로, 상기 MW 급 Segmented 형 아크 직류토치와 이를 구동하기 위한 대출력 초음속 열플라즈마 시험 시설에 대해 그 동안 전북대학교에서 진행되어 온 개념설계 내용을 소개하고자 한다. 덧붙여, 최근 본 사업단에서 선행 연구 중인 고엔탈피 초음속 열플라즈마 진단 계측 기법과 향후 응용분야 및 핵심 연구개발 과제 등에 대한 간략한 소개도 함께 하고자 한다.

  • PDF

Influence of Phenolic Compounds on vir Gene Expression in Various Agrobacterium tumefaciens (여러 종류의 Agrobacterium tumefaciens에서 vir 유전자의 발현에 영향을 미치는 페놀화합물)

  • Eum, Jin-Seong;Park, Young-Doo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.4
    • /
    • pp.253-260
    • /
    • 2000
  • The virulence(vir) genes in Ti plasmid at Agrobacterium tumefaciens are expressed by a phenolic compound synthesized at plant wound site. The vir genes inducing abilities of 8 phenolic compounds were tested using three wild type strains of A. tumefaciens. It was also investigated how the levels of vir gene expression among the strains tested could be related to the kinds of specific phenolic compounds. Five phenolic compounds like as 4-hydroxyacetophenone, phenol, catechol, resorcinol, and vanillin had exhibited a strong effect on the vir gene expression of A. tumefaciens MW102 whereas they did not be either non-functional or weakly inducible to the vir gene expression of other strains i.e. A. tumefaciens MW105 and MW108. Furthermore, the vir gene of A. tumefaciens MW102 was lowly expressed by acetosyringone that exposed an strong effect on the vir gene induction of other two strains. Thus, it appeared that the vir gene inducing abilities were differed by the kinds of phenolic compounds and Ti plasmids. In conclusion, we suppose that a change in vir gene inducing ability could be resulted from a difference of sensor protein expressed by vir A gene.

  • PDF

Effect of Fuel Mixing Ratio on Fuel Consumption in a Oil Fired Power Plant (중유화력발전소에서 바이오연료 혼합연소가 연료소비량에 미치는 영향)

  • Hong, Sangpil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.39-45
    • /
    • 2016
  • Each of fuel consumption per hour was measured at the 320 MW and 380 MW generator output while changing mixing ratio of bio fuel oil to 50%, 80% and 100%. Fuel consumption per hour was increased from 11.0% to 20.4% as mixing ratio of bio fuel oil was changed from 50% to 100% at the 320 MW generator output comparing with fuel consumption per hour in case of bunker-C oil single firing. Fuel consumption per hour was also increased from 12.0% to 21.1% as mixing ratio of bio fuel oil was changed from 50% to 100% at the generator output 380 MW. Furthermore, it was confirmed that plant efficiency was decreased as mixing ratio of bio fuel oil was increased from 50% to 100% as a result that plant efficiency was calculated using the measured fuel consumption per hour, the generator output and the gross heating value.

  • PDF