• Title/Summary/Keyword: MVR

Search Result 113, Processing Time 0.023 seconds

Clinical Analysis of Mitral Valvular Disease (승모판막 질환의 임상적 고찰)

  • 김창수
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.382-389
    • /
    • 1991
  • The clinical observations on the 63 cases of the mitral valvular heart disease treated in the department of Thoracic and Cardiovascular Surgery, Kosin medical college, during the period of 5 years from January, 1986 to December, 1989, are as follows. 1. Total 63 cases, 23 were male and 40 were female with sex ratio of 1: 1.7. 2. The age distribution was widely varied from 7 years of the youngest to 65 years oldest, average age was 35.3 year old. 3. The main clinical symptom and sign were D.O.E, general weakness, fatigability, palpitation, chest pain, hepatomegaly, pitting edema and both neck vein distension. 4. The preoperative N.Y.H.A functional classification were class II, III, IV in 28%, 54%, 16%. 5. The preoperative diagnosis were MS - 6.3%, MR - 53.9%, MSR - 36.5%, MVP - 3.1%. 6. All 63 patients were operated on the under direct vision using extracorporeal circulation, MVR in 18 cases, MVR and Tricuspid annuloplasty in 24 cases, DVR in 3 cases, DVR and Tricuspid annuloplasty in 5 cases, TVR in 1 case, Mitral annuloplasty in 4 cases, mitral valvuloplasty in 7 cases and mitral commissurotomy in 2 cases 7. The operative mortality was 7.9%, and 5 years actuarial survival rate was 89%.

  • PDF

Design and fabrication of a new piezoelectric paper feeder actuator without mechanical parts

  • Ghorbanirezaei, Shahryar;Hojjat, Yousef;Ghodsi, Mojtaba
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.183-191
    • /
    • 2019
  • A piezoelectric paper feeder actuator using Micro Virtual Roller (MVR) is proposed, designed, fabricated and tested. This actuator can drive a sheet of paper forward or backward without any mechanical parts, such as the costly and heavy rollers used in traditional paper feeders. In this paper feeder actuator, two vibrating stators which produce traveling waves are used to drive the paper. The vibrations of the stators are similar to those of piezoelectric motors and follow a similar procedure to move the paper. A feasibility study simulated the actuator in COMSOL Multiphysics Software. Traveling wave and elliptical trajectories were obtained and the dimensions of the stator were optimized using FEM so that the paper could move at top speed. Next, the eigenfrequencies of the actuator was determined. Experimental testing was done in order to validate the FEM results that revealed the relationships between speed and parameters such as frequency and voltage. Advantages of this new mechanism are the sharp decrease in power consumption and low maintenance.

The Cox-Maze Procedure for Atrial Fibrillation Concomitant with Mitral Valve Disease (승모판막질환에 동반된 심방세동에서 Cox-Maze 술식)

  • Kim, Ki-Bong;Cho, Kwang-Ree;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.939-944
    • /
    • 1998
  • Background: The sugical results of the Cox-Maze procedure (CMP) for lone atrial fibrillation(AF) have proven to be exellent. However, those for AF associated with mitral valve(MV) disease have been reported to be a little inferior. Materials and methods: To assess the efficacy and safety of the CMP as a combined procedure with MV operation, we studied retrospectively our experiences. Between April 1994 and October 1997, we experienced 70 (23 males, 47 females) cases of CMP concomitantly with MV operation. Results: The etiologies of MV disease were rheumatic in 67 and degenerative in 3 cases. The mean duration of AF before sugery was 66$\pm$70 months. Fifteen patients had the past medical history of thromboembolic complications, and left atrial thrombi were identified at operation in 24 patients. Twelve cases were reoperations. Aortic cross clamp (ACC) time was mean 151$\pm$44 minutes, and cardiopulmonary bypass (CPB) time was mean 246$\pm$65 minutes. Concomitant procedures were mitral valve replacement (MVR) in 19, MVR and aortic valve replacement (AVR) in 14, MVR and tricupid annuloplasty (TAP) in 8, MVR with AV repair in 3, MV repair in 11, MVR and coronary artery bypass grafting (CABG) in 2, MVR and AVR and CABG in 1, redo-MVR in 10, redo-MVR and redo-AVR in 2 patients. The rate of hospital mortality was 1.4%(1/70). Perioperative recurrence of AF was seen in 44(62.9%), and atrial tachyarrhythmias in 10(14.3%), low cardiac output syndrome in 4(5.7%), postoperative bleeding that required mediastinal exploration in 4(5.7%) patients. Other complications were acute renal failure in 2, aggravation of preoperative hemiplegia in 1, and transient delirium in 1 patient. We followed up all the survivors for 16.4 months(3-44months) on an average. Sinus rhythm has been restored in 65(94.2%) patients. AF has been controlled by operation alone in 73.9% and operation plus medication in 20.3%. Two patients needed permanent pacemaker implantation; one with sick sinus syndrome, and the other with tachycardia- bradycardia syndrome. Only two patients remained in AF. We followed up our patients with transthoracic echocardiography to assess the atrial contractilities and other cardiac functions. Right atrial contractility could be demonstrated in 92% and left atrial contractility in 53%.We compared our non-redo cases with redo cases. Although the duration of AF was significantly longer in redo cases, there was no differences in ACC time, CPB time, postoperative bleeding amount and sinus conversion rate. Conclusions: In conclusion, the CMP concomitant with MV operation demonstrated a high sinus conversion rate under the acceptable operative risk even in case of reoperation.

  • PDF

Clinical Analysis of Cardiac Valve Surgery (심장판막증의 외과적 치료)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.446-455
    • /
    • 1985
  • A total and consecutive 156 patients have undergone cardiac valve surgery including 13 closed mitral commissurotomy, 13 open mitral commissurotomy, one mitral annuloplasty, 75 mitral valve replacement, one aortic annuloplasty, 24 aortic valve replacement, 3 tricuspid valve replacement, 25 double valve replacement and one triple valve replacement. 155 prosthetic valves were replaced in a period between September 1976 and August 1985. There were 68 males and 88 females with age range from 8 to 69 yrs [mean 36.5 yr]. Out of replaced valves, 61 was tissue valve including 54 Carpentier-Edwards, and 4 was mechanical valves including 74 St. Jude Medical, and the position replaced was 101 valves for mitral, 46 for aortic and 8 for tricuspid. Single valve replacement in 102 cases, double valve replacement in 25 cases [17 for AVR+MVR, and 8 for MVR+TVR], and only one case was noted in the triple valve replacement. Early mortality within 30 days after operation was noted in 11 cases [7%]; 7 after MVR, 2 after DVR, and each one after open mitral commissurotomy and mitral annuloplasty. Cause of death was valve thrombus, cerebral air embolism, low output syndrome, uncontrollable arrhythmia, parapneumonic sepsis, acute cardiac tamponade and left atrial rupture. 7 late deaths were noted during the follow-up period from 1 to 104 months [average 48 month]; three due to valve and left atrial thrombus formation, two due to CVA from overdose of warfarin, and each one due to congestive heart failure and chronic constrictive pericarditis, Anticoagulants after prosthetic valve replacement were maintained with warfarin, dipyridamole and aspirin to the level of around 50% of normal prothrombin time in 79 cases, and Ticlopidine with aspirin in 47 cases to compare the result of each group. There were 11 major thromboembolic episodes including 3 deaths in the warfarin group. Two cases of CVA due to overdose of warfarin was noted in the warfarin group. In the ticlopidine group, there was only one left atrial thrombus confirmed at the time of autopsy. Among the survived 138 cases, nearly all cases[136 cases] were included in NYHA functional class I and II during the follow-up period. In conclusion, surgical treatment of the cardiac valve disease in 156 clinical cases revealed excellent result with acceptable operative risk and late mortality. Prevention of thrombus formation with anti-platelet aggregator Ticlopidine has better result than warfarin group presently with no specific side effect such as bleeding or gastrointestinal trouble.

  • PDF

Clinical study of endocardial cushion defect: 37 cases report (심내막상 결손증에 대한 임상고)

  • Jo, Jae-Il;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.657-665
    • /
    • 1984
  • Thirty-seven patients had undergone repair of a endocardial cushion defect between 1977 and Aug. 1983 in Seoul National University Hospital. Twenty eight had a partial defect, one intermediate defect and eight complete endocardial cushion defect. Tricuspid cleft was found in 4 cases and mitral cleft was in all p-ECD. Seven patients were of type C anatomy in c-ECD. Four patients had associated major anomalies, including three TOF in c-ECD, one coarctation in p- ECD. In p-ECD patients, the septal defect was closed with patch in all cases and the atrioventricular valvular insufficiency was corrected with MVR in 4 cases, TVR in 1 case and simple interrupted sutures in remainders. In c-ECD patients the septal defect was closed with single patch except one case. The atrioventricular valve was repaired with simple interrupted sutures except one MVR and TVR case. The operative mortality was 14.2% in p-ECD, 44.4% in c-ECD, but recent 3 years [1980-1983] mortality was 8.7% in p-ECD, 20% in c-ECD. More than grade III systolic regurgitant murmur was oted postoperatively in 4 cases of c-ECD and 3 cases of p-ECD. The operative risk factors were preoperative NYHA classification, cyanosis, Rp/Rs, systolic pressure of main pulmonary artery and the degree of regurgitation of atrioventricular valves. The causes of death were low cardiac output syndromes, pulmonary complications and arrhythmias.

  • PDF

clinical results of the xenograft cardiac valves (이종심보직판막의 임상적 평가)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.106-115
    • /
    • 1989
  • Clinical results with the xenograft cardiac valves were reviewed for 212 patients who underwent heart valve replacement from January 1981 to December 1987. One hundred and twenty-four Carpentier-Edwards k 88 Ionescu Shiley valves were used. Overall operative mortality was 11 out of 212[5.1%]: 5 out of 153[3.39o] for mitral valve replacement [MVR], 2 out of 34[5.9%] for aortic valve replacement [AVR], 0 out of 4[0%] for Tricuspid valve replacement [TVR], and 4 out of 21[19.1%] for double valve replacement [DVR;MVR+ AVR]. Two hundred and one operative survivors were followed up for a total of 824.3 patient-years [a mean 3.9*1.8 yrs], and the follow up was 78.1%. The linealized complication rates were 0.1% emboli / patient-year, 1.0% endocarditis/ patient-year and 2.2% overall valve failure / patient-year. A linealized rate of primary tissue failure was 0.7*/o/ patient-year. The actuarial survival rates including the operative mortality were 92*2.8% at 4 years and 85*4.3% at 7 years after surgery using the Xenograft cardiac valves. Probabilities of freedom from thromboembolism and overall valve failure were 73*11.0% and 69*2.4% at 7 years after surgery using the Xenograft cardiac valves respectively. The intrinsic durability of the Xenograft cardiac valves appears to be relatively well satisfactory over the long term [4 to 7 years] and the risk of failure appears well balanced by the advantages of a low incidence of thromboembolism and no mandatory anticoagulant therapy.

  • PDF

Parallel Processing for Integral Imaging Pickup Using Multiple Threads

  • Jang, Young-Hee;Park, Chan;Park, Jae-Hyeung;Kim, Nam;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • v.5 no.4
    • /
    • pp.30-34
    • /
    • 2009
  • Many studies have been done on the integral imaging pickup whose objective is to get efficiently elemental images from a lens array with respect to three-dimensional (3D) objects. In the integral imaging pickup process, it is necessary to render an elemental image from each elemental lens in a lens array for 3D objects, and then to combine them into one total image. The multiple viewpoint rendering (MVR) is one of various methods for integral imaging pickup. This method, however, has the computing and rendering time problem for obtaining element images from a lot of elemental lens. In order to solve the problems, in this paper, we propose a parallel MVR (PMVR) method to generate elemental images in a parallel through distribution of elemental lenses into multiple threads simultaneously. As a result, the computation time of integral imaging using PMVR is reduced significantly rather than a sequential approach and then we showed that the PMVR is very useful.

Short-term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis (St. Jude 기계판막의 단기및 중기 성적)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • St.Jude Medical cardiac valve replacement was performed in 322 patients: 191 had mitral, 58 had aortic, 72 had double valve and 3 had tricuspid valve replacement. Motality rate in early period was 2.8%[9 patients]. The most common cause of early death was low cardic output syndrome. Follow up extended from 1 to 90 months[mean: 34 months] in 292 patients among 313 in all surviving patients [93.6%]. There were thrombolic complications in eighteen patients. The probability of free from thromboembolism at 5 yerars in MVR, AVR and DVR were 84.7%, 91.8% and 90.2% respectively. And also, actuarial event free rate at 5 years in MVR, AVR and DVR were 80.1%, 82.2%, and 81.4% respectively. There were fourteen late death during follow up period: six from thromboembolism, one from hemorrhage and the others from non valve related -or unknown complications. The acturial survival rate at 5 years were 93.1% in mitral, 92.1% in aortic and 97.1% in double valve replacement. In conclusion, the performance of the St. Jude Mecanical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

Durability ofthe low-profile Ionescu-Shiley valve in mitral and aortic position (중복판막치환에서 이오네스큐 단고형 판막의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.26 no.1
    • /
    • pp.18-23
    • /
    • 1993
  • Improved clinical performance was expected from the introduction of the low-profile model of the Ionescu-Shiley pericardial valve. The long-term clinical results were assessed on the consecutive 47 patients who underwent MVR + AVR with this valve between 1984 and 1988. Three patients died within 30 days of surgery[operative mortality, 6.4%], and 44 early survivors were followed up for a total of 203.8 patient-years [Mean + SD, 4.63 + 1.47 years]. One died during the follow-up with a linearized late mortality of 0.491%/patient~year[pt-yr]. None experienced thromboembolism. Bleeding and endocardiris were seen in each single patient with the incidences of complication of 0.491%/pt-yr respectively. The linearized rate of primary tissue failure [PTF] was 0.491%/pt-yr. The actuarial survival and rate of freedom from PTF were 97.6 _+ 2.4% and 92.6 +7.1% at 7 years of follow-up.These results are favorably comparable with the ones seen in the patients of MVR + AVR with the standard profile lonescu-Shiley valve in all respects except the higher mean age of the low-profile group. Although the clinical performance was compatible with other major reports, the durability of the valve remains to be proved with the prolonged follow-up.

  • PDF

Clinical experience of open heart surgery: 12 cases (개심술 치험 보고: 12예)

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 1983
  • The report is concerned to our experience of 12 cases of open heart surgery under the extracorporeal circulation at the Department of Thoracic and Cardiovascular Surgery, Chosun University Hospital during the period between Nov, 1979 and April, 1983. 1. There were 4 cases of congenital anomaly and 8 cases of acquired heart disease. 2. There were 6 male and 6 female patients with a mean age of 20 years. [range 9 to 33 years]. 3. The cases induced 2 ventricular septal defect, 2 atrial septal defects and 8 acquired valvular heart diseases. 4. The surgical managements were 2 primary repair for atrial septal defect and 2 patch closure for ventricular septal defect, 1 triple valve replacement [AVR MVR TVR], 1 aortic valve replacement, 4 double valve replacement [AVR MVR] and 2 open mitral commissurotomy for pure mitral stenosis. 5. The average cardiopulmonary bypass time was 61.5 minutes for congenital heart disease and 201.4 minutes for acquired valvular heart disease and the average aortic cross clamping time was 36.75 minutes for the former and 165.6 minutes for the latter. 6. Postoperatively, there were 1 Alopecia, 1 Electric burn and 1 wound infection as complication. 7. Overall operative mortality was 8.3%. 7. All patients received valve replacement were recommended anticoagulation with persantin.

  • PDF