• Title/Summary/Keyword: MTR System

Search Result 29, Processing Time 0.024 seconds

A Restoration Automation Algorithm on a Fault in Substation of SCADA-coordinated Distribution Automation System (SCADA가 통합된 배전자동화 시스템의 변전소 사고 시 복구 자동화 알고리즘)

  • Hong, Jun-Ho;Lim, Il-Hyung;Lee, Seung-Jae;Kim, Tae-Wan;Choi, Myeon-Song;Ha, Bok-Nam;Lee, Sung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2107-2114
    • /
    • 2009
  • It is impossible to take the instant action in the distribution system When fault occures in a substation because operation of the substation and the distribution system are separated. However the power system automation has been studying about unity operation and co-operation between SCADA and DAS(Distribution Automation System). In this paper proposes a new algorithm of efficiency restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR in united system between DAS and SCADA. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads. In the case studies, the proposed algorithm have been verified in 2 MTR and 3 MTR substation

A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR (변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘)

  • Hong, Jun-Ho;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Kim, Tae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.

  • PDF

Rate 13/15 MTR code with j=2 constraint for high-density magnetic recording (고밀도 자기기록을 위한 j=2 구속 조건을 갖는 코드율 13/15인 MTR 코드)

  • 이규석;이주현;이재진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1034-1039
    • /
    • 2004
  • Since the major reason of the detection failure is from the consecutive data transitions, it is desirable to limit the MTR(maximum transition run) within two. Therefore, we propose a new MTR code that limits the MTR constraint to 2 and k-constraint to 8. In addition, DC-free coding is performed to overcome the media noise that exits in low frequency of perpendicular recording system. We use a GS (Guided Scrambling) for DC-free coding, and the performance of the code is compared with that of the rate 819 code used in the conventional recording channel by a computer simulation.

Preliminary trials on effectiveness of MTR(Mass Transfer Reactor) system in aerating fish stocks

  • Mock Huh;Kim, Boo-Gil
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.1
    • /
    • pp.23-31
    • /
    • 1999
  • An advanced mobile technology is described for saturating water with oxygen. The MTR(Mass Transfer Reactor) is 2~10 times more effective in dissolving oxygen in water compared to most other systems used in aquaculture, because it can generate extremely small(0.005~0.05mm) bubbles. New fish farming facilities could make use of this technology to build deeper ponds for raising multiple species with optimized conditions for DO(dissolved oxygen), food, light, etc. The proposed technology offers higher DO levels with minimal operating costs. It is easy to use and maintain, with a high reproducibility. Accordingly, the MTR can be industrially applied in the treatment of fish waste and reduction of water consumption during fish farming.

  • PDF

The Effect on Real Power System by the Inrush Current of a Transformer (변압기 돌입전류에 의한 실계통 영향 분석)

  • Shin, Jeong-Hoon;Jang, Gil-Soo;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.318-321
    • /
    • 1999
  • This paper describes the study of the effect on real power system due to the inclusion of the MTR at Buk Che-ju TP #2. The test system in which the transformers are represented in detail and rest Che-ju systems are represented as an equivalent system on the bus is simulated by the EMTDC. Simulation results include magnitude of inrush current and voltage drop on the bus at various CB closing time, and they show the effect on Che-ju system by the inrush current of the Buk Che-ju TP #2's MTR is not considerable.

  • PDF

A study on the Voltage analysis of Sung-san S/S MTr #1 Hang-won wind farm (제주 성산 S/S MTr #1 행원 풍력단지 전압해석)

  • Kim, Sang-Jun;Cho, Min-Ho;Yoon, Gi-Gab;Jang, Sang-Ok;Ahn, Jeong-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.345-347
    • /
    • 2003
  • 본 논문에서는 분산전원이 기존의 배전계통상에 도입되는 경우에 대하여 전압변동해석을 수행하기 위하여, 풍력발전단지가 도입된 제주 성산 변전소를 선정하여 MATLAB 프로그램을 이용하여 시뮬레이션을 수행하고 전압변동상황을 예측, 이에 따른 문제점과 그에 대한 대책을 제시하도록 할 것이다.

  • PDF

Modified Tikhonov regularization in model updating for damage identification

  • Wang, J.;Yang, Q.S.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.5
    • /
    • pp.585-600
    • /
    • 2012
  • This paper presents a Modified Tikhonov Regularization (MTR) method in model updating for damage identification with model errors and measurement noise influences consideration. The identification equation based on sensitivity approach from the dynamic responses is ill-conditioned and is usually solved with regularization method. When the structural system contains model errors and measurement noise, the identified results from Tikhonov Regularization (TR) method often diverge after several iterations. In the MTR method, new side conditions with limits on the identification of physical parameters allow for the presence of model errors and ensure the physical meanings of the identified parameters. Chebyshev polynomial is applied to approximate the acceleration response for moderation of measurement noise. The identified physical parameter can converge to a relative correct direction. A three-dimensional unsymmetrical frame structure with different scenarios is studied to illustrate the proposed method. Results revealed show that the proposed method has superior performance than TR Method when there are both model errors and measurement noise in the structure system.

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

Real-Time Bus Reconfiguration Strategy for the Fault Restoration of Main Transformer Based on Pattern Recognition Method (자동화된 변전소의 주변압기 사고복구를 위한 패턴인식기법에 기반한 실시간 모선재구성 전략 개발)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.596-603
    • /
    • 2004
  • This paper proposes an expert system based on the pattern recognition method which can enhance the accuracy and effectiveness of real-time bus reconfiguration strategy for the transfer of faulted load when a main transformer fault occurs in the automated substation. The minimum distance classification method is adopted as the pattern recognition method of expert system. The training pattern set is designed MTr by MTr to minimize the searching time for target load pattern which is similar to the real-time load pattern. But the control pattern set, which is required to determine the corresponding bus reconfiguration strategy to these trained load pattern set is designed as one table by considering the efficiency of knowledge base design because its size is small. The training load pattern generator based on load level and the training load pattern generator based on load profile are designed, which are can reduce the size of each training pattern set from max L/sup (m+f)/ to the size of effective level. Here, L is the number of load level, m and f are the number of main transformers and the number of feeders. The one reduces the number of trained load pattern by setting the sawmiller patterns to a same pattern, the other reduces by considering only load pattern while the given period. And control pattern generator based on exhaustive search method with breadth-limit is designed, which generates the corresponding bus reconfiguration strategy to these trained load pattern set. The inference engine of the expert system and the substation database and knowledge base is implemented in MFC function of Visual C++ Finally, the performance and effectiveness of the proposed expert system is verified by comparing the best-first search solution and pattern recognition solution based on diversity event simulations for typical distribution substation.

Development of WEB Based Remote Monitoring and Diagnostic System for Electric Power Transmission Apparatus (WEB 기반 변전설비 원격 감시/진단 시스템 개발)

  • Choi, Young-Jun;Yang, Hang-Jun;Choi, Yong-Bum;Kim, Sung-Sik;Kim, Jung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.183-185
    • /
    • 2002
  • 본 논문에서는 안정적인 변전소의 운영을 위해 최근 개발된 WEB 기반의 초고압 변전설비 원격감시 및 진단 시스템을 소개한다 WEB 기반의 초고압 변전설비 원격 감시 및 진단 시스템은 154kV급 이상의 초고압 변전소에 설치되어 있는 주변압기(MTR)와 가스절연개폐기(GIS)에 대한 감시 및 진단 데이터를 취득하는 Local System과 이러한 데이터를 전송 받아 감시 및 진단 기능과 WEB 서비스를 수행하는 Main Control Center로 구분된다. 실적용 사례로 최근 산업체의 몇 개 공장을 대상으로 시범 적응한 154kV급 변전소의 WEB 기반 감시 및 진단 시스템을 소개한다. 나아가 변전기기를 제어하기 위한 시스템과의 연계 방법에 대해 언급하고 있다.

  • PDF