• Title/Summary/Keyword: MTF assessment

Search Result 28, Processing Time 0.031 seconds

Development of a Natural Target-based Edge Analysis Method for NIIRS Estimation (NIIRS 추정을 위한 자연표적 기반의 에지분석기법 개발)

  • Kim, Jae-In;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.587-599
    • /
    • 2011
  • As one measure of image interpretability, NIIRS(National Imagery Interpretability Rating Scale) has been used. Unlike MTF(Modulation Transfer Function), SNR(Signal to Noise Ratio), and GSD(Ground Sampling Distance), NIIRS can describe the quality of overall image at user's perspective. NIIRS is observed with human observation directly or estimated by edge analysis. For edge analysis specially manufactured artificial target is used commonly. This target, formed with a tarp of black and white patterns, is deployed on the ground and imaged by the satellite. Due to this, the artificial target-based method needs a big expense and can not be performed often. In this paper, we propose a new edge analysis method that enables to estimate NIIRS accurately. In this method, natural targets available in the image are used and characteristics of the target are considered. For assessment of the algorithm, various experiments were carried out. The results showed that our algorithm can be used as an alternative to the artificial target-based method.

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

Design of Variable F-number and Triple Magnification Infrared Optical System (가변 F/수 삼중 배율 적외선 광학계 설계 연구)

  • Jeong, Yumee
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.153-162
    • /
    • 2021
  • In this article, the design of a variable F-number and triple magnification infrared optical system is described. That is a two-in-one optical system that combines an infrared search and track (IRST) system and an electro-optical tracking system (EOTS), where an afocal optical system is added to the IRST optical system designed already. The performance target is determined by analyzing system performance, and then the specification in the optical system design is calculated. This optical system contains a warm stop making it possible that one optics has two different F/# by cutting the size of aperture, and that is designed to suit this optics. The system satisfies the requirement such as a modulation transfer function (MTF). For operational assessment, the movement of the focusing lens group is analyzed over the change of temperature and target distance. By using this optical system, it is possible to develop equipment having two functions, infrared searching and electro-optical tracking.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Analysis of the application of image quality assessment method for mobile tunnel scanning system (이동식 터널 스캐닝 시스템의 이미지 품질 평가 기법의 적용성 분석)

  • Chulhee Lee;Dongku Kim;Donggyou Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.4
    • /
    • pp.365-384
    • /
    • 2024
  • The development of scanning technology is accelerating for safer and more efficient automated inspection than human-based inspection. Research on automatically detecting facility damage from images collected using computer vision technology is also increasing. The pixel size, quality, and quantity of an image can affect the performance of deep learning or image processing for automatic damage detection. This study is a basic to acquire high-quality raw image data and camera performance of a mobile tunnel scanning system for automatic detection of damage based on deep learning, and proposes a method to quantitatively evaluate image quality. A test chart was attached to a panel device capable of simulating a moving speed of 40 km/h, and an indoor test was performed using the international standard ISO 12233 method. Existing image quality evaluation methods were applied to evaluate the quality of images obtained in indoor experiments. It was determined that the shutter speed of the camera is closely related to the motion blur that occurs in the image. Modulation transfer function (MTF), one of the image quality evaluation method, can objectively evaluate image quality and was judged to be consistent with visual observation.

Subclinical Hypothyroidism;Controversial Subjects and Therapeutic Regimen (준임상적 갑상선기능저하증;논란이 되는 주제들)

  • Park, Ji-Hun;Kim, Ho-Jun;Lee, Myeong-Jong
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.6 no.2
    • /
    • pp.29-41
    • /
    • 2006
  • Subclinical hypothyroidism is defined as a normal serum free thyroxine level combined with an elevated thyroid stimulating hormone level. The causes of subclinical hypothyroidism are the same as those of overt hypothyroidism. There is good evidence that subclinical hypothyroidism is associated with progression to overt disease. The management of subclinical hypothyroidism is remains controversial. Patients with a serum thyroid stimulating hormone level greater than 10 mU/L have a higher incidence of elevated serum low-density lipoprotein cholesterol concentrations; however, evidence is lacking for other associations. There is insufficient evidence that hormone treatment of subclinical hypothyroidism is beneficial. The use of thyroid stimulating hormone level lone as a diagnostic and assessment tool for hypothyroidism is inadequate because this test cannot identify numerous conditions this sentence is unclear in its meaning. Using an expanded list of clinical signs and symptoms associated with dysfunction of the Hypothalamus-Pituitary-Thyroid axis, it is possible to hypothesize that subclinical hypothyroidism may be more common in a population of patients with early signs of age-related diseases than most practitioners realize. To improve thyroid function in subclinical hypothyroidism patients, practitioners should become familiar with foods and nutrients that can hinder or support thyroid function.

  • PDF

A Study of Optical System Design for a Retinal Camera (망막 카메라용 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 2006
  • We need a good image of the retina of the human eye in order to inspect or cure it. In this work, an optical system design for a retinal camera is studied and the finite schematic eye model made by Sang Gee Kim and Sung Chan Park is used. The optical system is composed of four lens groups. The rays of the entire object field are collected on the center by the 1st group and the objective is imaged by all the other groups. The image is detected by the CCD array and displayed by a monitor The 1st lens group is employed singlet and other groups are employed triplets. Ray aberrations, spot diagrams, diffraction line spread functions and MTFs are calculated for optical performance assessment. This design may be very useful for the development of a retinal camera with high performance.

The Analysis of Optical Quality in Central Serous Chorioretinopathy by OQAS (OQAS를 이용한 중심장액성맥락망막병증의 광학적 질 분석)

  • Choi, Jong Kil;Lee, Kyung Min;Kim, Heesung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.281-288
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the change of optical quality in fully cured eyes from central serous chorioretionopathy(CSC) and CSC under treatment, respectively. Methods: A total of 136 eyes(68 subjects) was divided into CMC under treatment and its asymptomatic contralateral eye, fully cured eyes after being diagnosed with CMC and its contralateral eye, and normal eyes. Objective scattering index, cut-off value in modulation transfer function, focusing rate, PSF(Point Spread Function) width at 50%, 10% and the contrast sensitivity were measured and analyzed. Results: CMC under treatment showed statistically significant decrease in all evaluations of optical quality compared with asymptomatic contralateral eyes, fully cured eyes and normal eyes. Although there was no significant difference in optical quality between asymptomatic contralateral eyes of CMC under treatment and fully cured eyes, there was tendence in optical quality decreasing compared with normal eyes. Conclusions: From the study, it was revealed that the optical quality was different according to the treatment phase in CMC. The use of optical quality assessment for the decision of complete cure and the evaluation of prognosis in CMC is also proposed.