• Title/Summary/Keyword: MTF 평가

Search Result 139, Processing Time 0.022 seconds

The Additional Filter and Ion Chamber Sensor Combination for Reducing Patient Dose in Digital Chest X-ray Projection (디지털 흉부엑스선 검사에서 환자선량 감소를 위한 부가필터와 Ion chamber 센서 조합)

  • Lee, Jinsoo;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, we studied additional filter and Ion chamber combinations to reduce patient dose without decreasing image quality in digital chest x-ray projection. The experiment set 125 kVp, 320 mA, AEC mode. Ion chamber sensors was divided by 4 cases of combinations, then, we measured patient dose and calculated organ dose using PCXMC. Also, physical image assessment using MTF was performed. As a results, The surface entrance dose and organ dose were the lowest when selecting both left and right Ion chamber sensors under the same conditions of additional filter. In image quality assessment, The spatial frequency scored 2.494 lp/mm which was highest when selecting both right and left Ion-chambers and 0.1 mmCu filter. And to conclude, to select both right and left Ion chamber sensors and 0.1 mmCu filter will help for acquiring good quality image as well as reducing patient dose.

Evaluation of Image Quality using Monte Carlo Simulation in Digital Mammography System (디지털유방영상시스템에서 몬테카를로 시뮬레이션을 이용한 영상평가)

  • Kim, Changsoo;Kang, Se-Sik;Kim, Jung-Hoon;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.247-254
    • /
    • 2014
  • For the purpose of early diagnosis of the breast cancer, the attention on the screening mammography has been increasing-with supply of digital mammography day by day. Image quality is decided by target materials and filter combinations. Optimized selection by a glandular density and a thickness is needed, because these combinations change x-ray spectrum and effect to image quality. The purpose of this study is to find out optimized target and filter combinations through the evaluation of quantitative image quality and to suggest means which minimize patient dose through MCNPX. In results, spatial frequency resolution evaluation which is quantitative image quality evaluation method, MTF, NPS, DQE shows that we have to select Mo/Mo combinations or Mo/Rh combinations when compressed breast is thin. but in case of that when compressed breast is thick, we have to select Rh/Rh combinations or W /Rh combinations. In a comprehensive evaluation, W!Rh combinations which are not used in thin breasts in practice was superior to all image quality evaluation. This result is somewhat different-with clinical examination results. Secondary end point was organ dose evaluation, radiation dose of opposite breast was approximately 47 ~73% effectiveness when selecting standard breast. In conculsion, the most important point is that we have to select the optimal combinations-with considering dose evaluation and various thickness.

Analysis of the application of image quality assessment method for mobile tunnel scanning system (이동식 터널 스캐닝 시스템의 이미지 품질 평가 기법의 적용성 분석)

  • Chulhee Lee;Dongku Kim;Donggyou Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.4
    • /
    • pp.365-384
    • /
    • 2024
  • The development of scanning technology is accelerating for safer and more efficient automated inspection than human-based inspection. Research on automatically detecting facility damage from images collected using computer vision technology is also increasing. The pixel size, quality, and quantity of an image can affect the performance of deep learning or image processing for automatic damage detection. This study is a basic to acquire high-quality raw image data and camera performance of a mobile tunnel scanning system for automatic detection of damage based on deep learning, and proposes a method to quantitatively evaluate image quality. A test chart was attached to a panel device capable of simulating a moving speed of 40 km/h, and an indoor test was performed using the international standard ISO 12233 method. Existing image quality evaluation methods were applied to evaluate the quality of images obtained in indoor experiments. It was determined that the shutter speed of the camera is closely related to the motion blur that occurs in the image. Modulation transfer function (MTF), one of the image quality evaluation method, can objectively evaluate image quality and was judged to be consistent with visual observation.

Quantitative characteristics of a new high-voltage CCD camera (신규 설치된 HVEM용 고전압 CCD 카메라의 정략 특성 평가)

  • Kim, Yeong-Min;Kim, Yun-Jung
    • 한국전자현미경학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.84-89
    • /
    • 2007
  • 카메라의 정량 평가 결과로부터 신규 설치된 HVEM용 고전압 CCD 카메라 (SPUS1000 HV-IF)는 기존의 HV-MSC 카메라에 비해 read-out noise level과 shot noise 발생거동, average gain, dynamic range, uniformity, DQE 등이 향상된 결과를 보여 주었고 MTF는 전과 유사한 결과를 나타내었다. 그러나 linearity가 HV-MSC 카메라에 비해 그 범위가 좁으며 낮은 전자 조사 조건하에서는 전반적인 카메라 성능이 오히려 HV-MSC 카메라의 경우보다 낮은 결과를 나타내었다. 따라서 본 신규 카메라는 낮은 전자 조사 조건이 필요한 실험에서는 기록 성능의 개선을 나타내지 않지만 고속 영상 기록 기능을 활용한 재료의 역동적 분석과 함께 원자분해 영상 작업과 EELS 분석에 있어선 이전 보다 기록 성능의 뚜렷한 개선을 나타낼 것으로 기대할 수 있다.

  • PDF

Speech Intelligibility Analysis on the Laser Detected Sound of the Glass Windows (유리창의 레이저 탐지음에 대한 음성명료도 분석)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Hee-Dong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.127-134
    • /
    • 2009
  • In this study, possibility of the laser eavesdropping is investigated on the window glasses with various thicknesses, Glass windows are excited by maximum length sequency (MLS) signal and the vibration sound is detected by a laser doppler vibrometer. From the detected sound, speech intelligibility is objectively estimated. Speech transmission index (STI), which is based on the modulation transfer function (MTF). is calculated for the estimation. Finally, disturbing wave effect on the speech intelligibility is analysed by using an outside speaker and a window shaker attached on the glass window. The purpose of the study is to estimate the possibility of remote eavesdropping by the laser sensor and to evaluate the performance of the homemade window shaker to protect from the remote eavesdropping.

An Efficient Data Processing Method to Improve the Geostationary Ocean Color Imager (GOCI) Data Service (천리안 해양관측위성의 배포서비스 향상을 위한 자료 처리 효율화 방안 연구)

  • Yang, Hyun;Oh, Eunsong;Han, Tai-Hyun;Han, Hee-Jeong;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • We proposed and verified the methods to maintain data qualities as well as to reduce data volume for the Geostationary Ocean Color Imager (GOCI), the world's first ocean color sensor operated in geostationary orbit. For the GOCI level-2 data, 92.9% of data volume could be saved by only the data compression. For the GOCI level-1 data, however, just 20.7% of data volume could be saved by the data compression therefore another approach was required. First, we found the optimized number of bits per a pixel for the GOCI level-1 data from an idea that the quantization bit for the GOCI (i.e. 12 bit) was less than the number of bits per a pixel for the GOCI level-1 data (i.e. 32 bit). Experiments were conducted using the $R^2$ and the Modulation Transfer Function (MTF). It was quantitatively revealed that the data qualities were maintained although the number of bits per a pixel was reduced to 14. Also, we performed network simulations using the Network Simulator 2 (Ns2). The result showed that 57.7% of the end-toend delay for a GOCI level-1 data was saved when the number of bits per a pixel was reduced to 14 and 92.5% of the end-to-end delay for a GOCI level-2 data was saved when 92.9% of the data size was reduced due to the compression.

Development of a Natural Target-based Edge Analysis Method for NIIRS Estimation (NIIRS 추정을 위한 자연표적 기반의 에지분석기법 개발)

  • Kim, Jae-In;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.587-599
    • /
    • 2011
  • As one measure of image interpretability, NIIRS(National Imagery Interpretability Rating Scale) has been used. Unlike MTF(Modulation Transfer Function), SNR(Signal to Noise Ratio), and GSD(Ground Sampling Distance), NIIRS can describe the quality of overall image at user's perspective. NIIRS is observed with human observation directly or estimated by edge analysis. For edge analysis specially manufactured artificial target is used commonly. This target, formed with a tarp of black and white patterns, is deployed on the ground and imaged by the satellite. Due to this, the artificial target-based method needs a big expense and can not be performed often. In this paper, we propose a new edge analysis method that enables to estimate NIIRS accurately. In this method, natural targets available in the image are used and characteristics of the target are considered. For assessment of the algorithm, various experiments were carried out. The results showed that our algorithm can be used as an alternative to the artificial target-based method.

Performance Criterion of Bispectral Speckle Imaging Technique (북스펙트럼 스펙클 영상법의 성능기준)

  • 조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 1993
  • In the case of an imaging system affected by aberrations which are not precisely known, the effect of aberrations can be minimized and near-diffraction-limited images can be restored by introducing artificial random phase fluctuations in the exit pupil of the imaging system and using bispectral speckle imaging. In order to determine the optimum value of the correlation length for Gaussian random phase model, computer simulation is performed for 50 image frames of a point object in the presence of defocus, spherical aberration, coma, astigmatism of 1 wave, respectively. In terms of the criterion of performance, the FWHM of the point spread function, normalized peak intensity, MTF and visual inspection of the restored object are employed. The optimum value for the rms difference $\sigma$ of aberration on the exit pupil in the interval of Fried parameter ${\Upsilon}_0$ is given by 0.27-0.53 wave for spherical aberration, and 0.24-0.36 wave for defocus and astigmatism, respectively. It is found that the bispectral speckle imaging technique does not give good results in the case of coma.

  • PDF

A Study of Optimum Molding Condition of Aspheric Glass Lens(I) ; Annealing Condition Effect (비구면 Glass렌즈 최적 성형조건 연구(I) ; 서냉조건효과)

  • Cha, Du-Hwan;Kim, Hyeon-Uk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2006.07a
    • /
    • pp.197-198
    • /
    • 2006
  • 본 연구에서 개발하는 성형렌즈는 그림1과 같이 한쪽 면이 비구면인 평볼록 형상이다. Glass렌즈의 고온압축성형을 위해서는 초정밀 가공기술로 제작된 성형Mold가 필요하며, Mold재질에 따른 성형기술의 확립이 필수적이다. 또한, 성형Mold의 표면과 융착반응이 없는 Glass소재가 요구된다. 본 실험을 위한 성형Mold는 코발트(Co) 함량 0.5 %의 초경합금(WC; 일본, Everloy社, 002K)을 초정밀 연삭가공하여 제작하였다. Glass소재는 전이점(Transformation Point; Tg) $572\;^{\circ}C$,항복점(Yielding Point; At) $630\;^{\circ}C$의 열적 특성을 갖는 K-BK7(일본, Sumita社)을 사용하였으며, d선에서 굴절률 및 아베수는 각각 1.51633, 64.1이다. 비구면 Glass렌즈 성형은 GMP(Glass Molding Press; 일본, Sumitomo社, Nano Press-S)장비를 사용하여 성형온도 $625\;^{\circ}C$, 서냉온도 $550\;^{\circ}C$로 고정하고 성형압력를 200-800 N 범위에서 변화시켰다. 표 1에 성형변수로 사용한 서냉속도와 서냉전환온도 조건을 나타낸다. 표1과 같이 각 서냉조건별로5장의 렌즈를 성형 후 특성값이 평균치에 가까운 3장을 선별하여 그 특성을 비교하였다. 각 조건에 따른 성형렌즈의 형상정도(일본, Panasonic社, UA3P, 자유곡면형상측정기), 두께(일본, Mitutoyo社, MDC-25M, 마이크로메터), 굴절률(일본, Shimatus社, KPR-200, 정밀굴절률측정기) 및 MTF[해상도](독일, Trioptics社, Image Master HR, MTF-Field)를 측정하여 각각의 광학적 특성을 비교 평가하였다. 비구면 Glass렌즈 성형장비와 형상측정기를 그림 2, 3에 각각 나타낸다.

  • PDF

Evaluation of image acquisition using synchrotron radiation in CMOS sensor. (Synchrotron Radiation을 이용한 CMOS sensor image 획득평가)

  • Kim, D.H.;Park, J.K.;Choi, J.Y.;Chang, G.W.;Youn, G.J.;Moon, C.W.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.396-399
    • /
    • 2003
  • In this paper, the purpose is to develop imaging technique of synchrotron radiation using CMOS image sensor. The detector using hybrid method to be research in this lab was used, in order to increase image signal. We made experiments with 1B2 Whitebeam/microprobe beamline in PAL (Pohang Accelerator Laboratory). Phosphor materials such as ZnS:(Ag,Li), ZnS:(Cu,Al), $Y_2O_2S:Eu$ were produced by spin coating on glass. Synchrotron radiation images were acquired and evaluated from monochromatic light from monochromoator in PAL 1B2line. From obtained object and phantom, MTF was 0.15 in ZnS:(Ag,Li) phosphor, and 0.178 in ZnS:( Cu,Al) at 151p/mm. MTFs were unsystematic because thickness of phosphor and uniformity of surface were not optimized. It's expected to improve MTF and the qualify of images as uniformity's optimized.

  • PDF