• Title/Summary/Keyword: MTF 측정방법

Search Result 47, Processing Time 0.024 seconds

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography (간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Characteristics of KOMPSAT-3A Key Image Quality Parameters During Normal Operation Phase (정상운영기간동안의 KOMPSAT-3A호 주요 영상 품질 인자별 특성)

  • Seo, DooChun;Kim, Hyun-Ho;Jung, JaeHun;Lee, DongHan
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1493-1507
    • /
    • 2020
  • The LEOP Cal/Val (Launch and Early Operation Phase Calibration/Validation) was carried out during 6 months after KOMPSAT-3A (KOMPSAT-3A Korea Multi-Purpose Satellite-3A) was launched in March 2015. After LEOP Cal/Val was successfully completed, high resolution KOMPSAT-3A has been successfully distributing to users over the past 8 years. The sub-meter high-resolution satellite image data obtained from KOMPSAT-3A is used as basic data for qualitative and quantitative information extraction in various fields such as mapping, GIS (Geographic Information System), and national land management, etc. The KARI (Korea Aerospace Research Institute) periodically checks and manages the quality of KOMPSAT-3A's product and the characteristics of satellite hardware to ensure the accuracy and reliability of information extracted from satellite data of KOMPSAT-3A. To minimize the deterioration of image quality due to aging of satellite hardware, payload and attitude sensors of KOMPSAT-3A, continuous improvement of image quality has been carried out. In this paper, the Cal/Val work-flow defined in the KOMPSAT-3A development phase was illustrated for the period of before and after the launch. The MTF, SNR, and location accuracy are the key parameters to estimate image quality and the methods of the measurements of each parameter are also described in this work. On the basis of defined quality parameters, the performance was evaluated and measured during the period of after LEOP Cal/Val. The current status and characteristics of MTF, SNR, and location accuracy of KOMPSAT-3A from 2016 to May 2020 were described as well.

A Simple Human Visual Weighted Hadamard Transform Image Coding (단순한 시각적 하중에 의한 아다마르 영상부호화)

  • Hwang, Jae-Jeong;Lee, Moon-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.4
    • /
    • pp.98-105
    • /
    • 1989
  • Various models incorporating Human Visual System (HVS) with the Hadamard transform (HT) represented by Walsh functions are considered. Using the exact frequency components of HT basis functions, the optimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtained analytically and visually. The main criterion, for error measurement, is errors at the block boundaries which is an important factor in transform coding. The scheme which has no inverse HVS is proposed. It causes some degradation of image data but it is insignigicant. Crossing area of 4 blocks is equalized by the HVS weighting coefficients. The HVS weighted coding results in perceptually higher quality images compared with the unweighted scheme.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.