• Title/Summary/Keyword: MTF 측정방법

Search Result 47, Processing Time 0.023 seconds

MTF Assessment and Image Restoration Technique for Post-Launch Calibration of DubaiSat-1 (DubaiSat-1의 발사 후 검보정을 위한 MTF 평가 및 영상복원 기법)

  • Hwang, Hyun-Deok;Park, Won-Kyu;Kwak, Sung-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.573-586
    • /
    • 2011
  • The MTF(modulation transfer function) is one of parameters to evaluate the performance of imaging systems. Also, it can be used to restore information that is lost by a harsh space environment (radioactivity, extreme cold/heat condition and electromagnetic field etc.), atmospheric effects and falloff of system performance etc. This paper evaluated the MTF values of images taken by DubaiSat-1 satellite which was launched in 2009 by EIAST(Emirates Institute for Advanced Science and Technology) and Satrec Initiative. Generally, the MTF was assessed using various methods such as a point source method and a knife-edge method. This paper used the slanted-edge method. The slantededge method is the ISO 12233 standard for the MTF measurement of electronic still-picture cameras. The method is adapted to estimate the MTF values of line-scanning telescopes. After assessing the MTF, we performed the MTF compensation by generating a MTF convolution kernel based on the PSF(point spread function) with image denoising to enhance the image quality.

Modulation Transfer Function Measurement of a Linear Charge Coupled Device Imager by Using a Knife-Edge Scanner (칼날주사방법에 의한 일차원 CCD의 MTF 측정)

  • 조현모;이윤우;이인원;이상태;이종웅
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.173-177
    • /
    • 1995
  • The scanning type modulation transfer function (MTF) measurement system of linear charge coupled device (CCD) imagers is fabricated and the MTF of a linear CCD imager is tested. Measured MTF values are very sensitive to small angle knife-edge skew within 1 degree and show different results in several wavelengths. The MTF of the linear CCD imager is measured in different color temperatures of a tungsten filament lamp and the MTF uniformity of ti,t eel) pixels is tested.tested.

  • PDF

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF (Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구)

  • Choi, Siyoun;Kim, Junghwan;Kong, Hyunbae;Kim, Donghwan;Baek, Kyounghoon;Park, Ingu;Jeon, Hyowon;Lee, Kinam
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.310-316
    • /
    • 2022
  • In this paper, the difference in modulation transfer function (MTF) results according to the change in the angle of a slant target when measuring a presampled MTF was confirmed, and the difference was reduced by fitting the edge spread function graph obtained to reduce the error by the target's rotation. Due to the feature of the presampled MTF method, the spatial frequency changed due to the sensor's projected intensity being changed by the target's rotation, and it was confirmed that the difference in the MTF value occurred depending on the rotation angle of the target. In this paper, the MTF was calculated after fitting only one column of the acquired image. It was confirmed that the rotation error is smaller compared to the case of the presampled MTF method and this fitting method can be applied to a scene that contains various target angles, such as auto-focusing using the MTF.

Backward Testing Method of MTF measurement for optical engine of CRT of rear projection HDTV (후면투사식 CRT 고화질 텔레비전용 광학엔진의 변조전달함수 측정을 위한 후방검사 변조전달함수 측정법)

  • Song, Jong-Sup;Jo, Jae-Heung;Hong, Sung-Mok;Lee, Yun-Woo;Song, Jae-Bong;Lee, Hoe-Yun;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.56-62
    • /
    • 2005
  • Because of the wide plane and the curved field of CRT rear projection high definition television, its MTF(modulation transfer function) can't be easily measured by the usual forward testing method. Then we propose a backward testing method for the MTF so that the object plane and the image analyzer of forward testing are located at positions opposite each other. We prefer to use the backward testing method because the forward testing method has poor accuracy caused by very small numerical aperture, low spatial resolutions, and long depth of focus. We found that the backward testing method was very easy to align and had high repeatability. We confirmed the confidence of results obtained by the backward testing method in comparison with designed results.

A Study on the MTF Graphics using Simpson Approximation (심프슨 근사법을 이용한 MTF 그래프 작성에 관한 연구)

  • Che, Gyu-Shik;Chang, Won-Seok;Oh, Jake
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.401-408
    • /
    • 2012
  • There is a clear need for characterizing optical components with the growing role played by optical devices in measurement, communication, and photonics. A basic and useful measuring parameter to meet this need, especially for imaging systems, is the Modulation Transfer Function, or MTF. Over the past few decades new instrument, including the laser interferometer, the CCD camera, and the computer have revolutionized the measurement and calculation of the MTF. This has made what was tedious and involved into virtually an instantaneous measurement. We proposed a Simpson approxiamtion method to create MTF graph and illustrated real example to verify its method in this paper. This method is very useful while it is very useful because its error is very minor and small although its approximation.

SATELLITE OPERATION DESIGN FOR ASSESSING MTF PERFORMANCE OF EARTH OBSERVATION SATELLITE USING STELLAR SOURCES (별을 이용한 지구 관측 위성의 MTF 성능 분석을 위한 위성 운영 설계)

  • Kim, Hee-Seob;Chung, Dae-Won;Choi, Hae-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.379-388
    • /
    • 2007
  • Modulation Transfer Function (MTF) of satellite image is an important performance index in satellite image applications. Therefore MTF performance is assessed using satellite image for the ground target during LEOP phase after launch. But the MTF performance assessment using the ground target can be affected by imaging conditions such as cloud and weather. In this paper system requirements and satellite operation for assessing MTF performance of satellite image using stellar sources are proposed. Satellite capability in collecting stellar sources using the satellite which is designed for earth observation and satellite image usefulness for assessing MTF performances were analyzed. The proposed approach will be useful to assess MTF performance of earth observation satellite in lower earth orbit.

Modulation Transfer Function with Aluminum Sheets of Varying Thickness (다양한 두께의 알루미늄 판을 이용한 MTF 측정에 관한 연구)

  • Rhee, Dong Joo;Kim, Me Young;Moon, Young Min;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.55-63
    • /
    • 2016
  • We studied the method to gain a clear LSF using a thick aluminum sheet and to acquire the spatial resolution value with a high accuracy for a low spatial resolution imaging modality. In this study, aluminum sheets with thicknesses varying from 0.3 mm to 1.2 mm were tested to derive a modulation transfer function (MTF) for the oversampling and non-oversampling methods. The results were evaluated to verify the feasibility of the use of thick sheets for periodic quality assurance. Oversampling was more accurate than non-oversampling, and an aluminum sheet with a correction factor less than 2 at the cut-off frequency, which was less than 0.8 mm in this case, was confirmed to be suitable for MTF measurements. Therefore, MTF derivation from a thick aluminum sheet with thickness correction is plausible for a medical imaging modality.

Change of MTF for Sampling Interval in Digital Detector (디지털 검출기에서 샘플링 간격에 따른 MTF의 변화)

  • Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.225-230
    • /
    • 2014
  • Assessments of medical image was improved in accordance with development of medical imaging systems. One of them is edge method to determining MTF(Modulation Transfer Function) based on the Fujita method. Fujita was reduced sampling interval used slightly angulated slit to the direction of pixel array and composited finely sampled LSF to determine presampling MTF. In this study, we investigate the effect of sampling interval on the MTF under a digital imaging system by changing wire angle. The wire method was equivalent to the slit method except signal appearance. A Simens's MAMMOMAT Inspiration with $0.085{\times}0.085mm^2$ pixel size made by amorphous selenium was used and 96% accuracy on MTF in twice sampling interval compared with Fujita was obtained. However, three times of sampling interval showed 93% accuracy on 50% of MTF and 85% accuracy on 10% of MTF.

MTF comparision of CCD camera measured by two methods: Twyman-Green interferometer method and zoom lens method with three sinusoidal gratings (트와이만-그린 간섭계를 이용한 CCD의 MTF 값과 줌 렌즈를 이용한 CCD의 MTF 값 측정 비교.)

  • 홍성목;조재흥;임천석;이윤우;이회윤
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.28-29
    • /
    • 2003
  • 각종 렌즈 및 카메라, 망원경, 현미경 등 다양한 광학계들이 설계 및 개발 되고 있는 시점에서 그 성능을 정확하게 평가하는 것이 매우 중요하다. 광학계의 성능 평가를 위해서는 크게 정성적인 방법과 정량적인 방법으로 나눌 수 있는데, 정성적인 방법에 의한 평가는 분해능 표판이나 주기적인 격자의 상을 스크린 등에 결상시킨 후 사람의 눈을 통해서 한계 분해능을 평가하는 방법이다. 정량적인 방법에 의한 평가는 OTF(Optical Transfer Function)를 측정하거나 설계 자료를 통해 계산해 내는 것이다. (중략)

  • PDF