• Title/Summary/Keyword: MTBE(Methyl Tert-Butyl Ether)

Search Result 48, Processing Time 0.022 seconds

Analysis of Haloacetic Acids in Drinking Water by Direct Derivatization and Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HAAs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.638-648
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of haloacetic acid (HAAs). In this study, headspace solid-phase microextraction (HS-SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of HAAs in drinking water. The method involves direct derivatization of the acids to their methyl esters without methyl tert-butyl ether (MTBE) extraction, followed by HS-SPME with a $2cm-50/30{\mu}m$ divinylbenzene/carboxen/polydimethylsiloxane fiber. The effects of experimental parameters such as selection of SPME fiber, the volume of sulphuric acid and methanol, derivatization temperature and time, the addition of salts, extraction temperature and time, and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The $2cm-50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, sulphuric acid of 1ml, methanol of 3ml, derivatization temperature of $50^{\circ}C$ derivatization time of 2hrs, sodium chloride salt of 10g, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were selected as the optimal experimental conditions for the analysis of HAAs. The linearities ($r^2$), relative standard deviations (%RSD) and limits of detection (LOD) for HAAs were 0.9978~0.9991, 1.1~9.8% and $0.05{\sim}0.2{\mu}g/l$, respectively.

The Treatment of LNAPL(BETXlMTBE) Contaminated Groundwater Applying Photo-assisted Fenton Reaction with Various Fe(III) Chelator (Photo-assisted Fenton 반응에 다양한 Fe(III) chelator를 적용한 LNAPL(BTEX/MTBE)오염 지하수 처리에 관한 연구)

  • Park, Jong-Hun;Do, Si-Hyun;Lee, Hong-Kyun;Jo, Young-Hoon;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2009
  • In this study, the degradation of BTEX (benzene, toluene, ethylbenzene, xylene) was tested in both (Fe$^{3+}$+chelating agent)/H$_2$O$_2$system [Fe(III) 1 mM, oxalate 6 mM, H$_2$O$_2$ 3%, and pH 6] and UV/(Fe3++ chelating agent)lHzOz system [UV dose 17.4 kWhlL, Fe(III) 1mM, oxalate 6 mM,H$_2$O$_2$ 1%, and pH 6]. The types of chelating agents used in experiments were catechol, NTA, gallic, acetyl acetone, succinic, acetate, EDTA, citrate, malonate, and oxalate and the optimum chelating agent for BTEX degradation was determined. The results showed that acetate was the optimum chelating agent for BTEX degradation in both (Fe$^{3+}$+chelating agent)/H$_2$O$_2$ and UV/(Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system, and UV radiation enhanced the degradation of BTEX with any types of chelating agents. Moreover, UV/(Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system, which chelating agent was acetate, removed effectively mixtures of BTEX and MTBE (methyl tert-butyl ether) when the concentration of both BTEX and MTBE was 200 mg/L, respectively. In this system, BTEX was degraded completely and 85% of MTBE was degraded at the reaction time of 180 min. Therefore, UV/((Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system with acetate as a chelating agent removed not only BTEX but also BTEX and MTBE, effectively.

Ecological Risk Assessment based on Watershed System Assimilative Capacity in take Texoma, Texas-Oklahoma, USA (유역시스템 정화력을 고려한 생태위해성평가 사례연구: Lake Texoma Watershed (TX&OK, USA)를 대상으로)

  • An, Youn-Joo;Donald H. Kampbell;Guy W. Sewell
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.27-27
    • /
    • 2003
  • Lake Texoma is located on the border of southern Oklahoma and northern Texas. It has 93,000 surface acres, and is a focus of the recreation, and farming industries in the region. There are potential stressors around the Lake Texoma watershed that may cause adverse ecological effects in the lake. System assimilative capacity (SAC) is the ability of abiotic and biotic processes to atteuniate the stressors. SAC Exceeded indicates potential of occuring adverse eco-effects. A number of representative chemical release sites and stressor sources in the surrounding watershed were characterized, and several impact sites having stressors sources, such as being near agriculture, landfills, housing areas, oil production fields and heavy use recreational activity, were selected for surface water, sediment, and groundwater monitoring. A paired reference site, having similar physical characteristics as its impact site, was also chosen based on its proximity to the impact site. Lake water samples were collected at locations identified as marina entrance, gasoline filling station, and boat dock at five marinas selected on Lake Texoma from September 1999 to December 2001. Paired water and sediment samples were also collected. Groundwater samples were collected at about 70 producing monitoring wells. Water quality parameters measured were inorganics (nitrate, nitrite, orthophosphate, ammonia, sulfate, and chloride), dissolved methane, total organic carbon (TOC) (or DOC), volatile organic compounds (VOCs) such as methyl tert-butyl ether (MTBE) and BTEX, and a suite of metals. Biotic communities were evaluated at impact and reference sites. Five basic components were measured; two terrestirial components (plants and bird comminitires) and three aquatic components (benthic inverbrates, litteral-zone fishes, ecosystem attribures). Potential impacts to these comminites were evaluated.

  • PDF

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers (확산포집기로 공기중 ppb 농도수준의 휘발성유기물질 포집시 확산길이와 기류변화가 시료포집속도에 미치는 영향)

  • Byeon, Sang-Hoon;Stock, Thomas H.;Morandi, Maria T.;Afshar, Masoud;Cross, Jay
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.34-41
    • /
    • 2001
  • Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.

  • PDF

Characterization of Crosslinked Poly(vinyl alcohol) Membranes for the Preparation of Composite Membranes and Its Application to Pervaporation Separation (복합막 제조를 위한 가교된 폴리비닐알코올 막의 특성 평가와 이를 이용한 투과증발 분리)

  • 김연국;이정민;임지원;이영무
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.157-162
    • /
    • 1999
  • In the crosslining reaction of poly(vinyl alcohoJ)(PVA) with sulfur-succinic acid which had been established in our previous work, reaction temperature, 15$0^{\circ}C$, was so high to collapse the pore struc¬tures in support membrane for the preparation of composite membrane. Therefore, the efforts have been focused on lowering of the reaction temperature to 100$^{\circ}$C by using a catalysis, HC!. The newly established crosslinking reaction was characterized through the analysis of the chemical and thermal properties. From these results, the optimum conditions for the membrane preparation couId be drawn as followings : (i) reac¬tion temperature, 100 $^{\circ}C$,(ii) reaction time, 90 min, (iii) the concentration of the catalysis (HCD, 1.5%. Com¬posite membranes were fabricated by coating a casting solution containing PYA, sulfur-succinic acid and HCl on a support membrane followed by crosslinking it at 10$0^{\circ}C$. The resulting membranes were applied to the pervaporation separation of methyl-tert-butyl ether(MTBE)/methanol (MeOH) mixtures at 30, 40, and 5O$^{\circ}C$. The flux of 5.09 g/$m^2$hr at 5O$^{\circ}C$ and the highest separation factor of 1622 were obtained, respectively.

  • PDF

Characteristics of Groundwater, Sewage Water and Stream Water Contamination Based on VOCs Concentration Around Ulsan, Korea (울산지역 지하수, 하수 및 하천수의 VOCs 오염특성)

  • Cho, Byong-Wook;Yun, Uk;Im, Hyun-Chul;Sung, Ig-Hwan;Jang, Woo-Seog
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.57-65
    • /
    • 2005
  • To investigate the characteristics of the volatile organic compounds (VOCs) concentration in the groundwater around Ulsan, Korea, 168 groundwaters, 12 stream waters, and 6 sewage waters were analyzed for 61 VOCs. Results showed that VOCs were not detected in stream waters and total VOCs concentration in 5 sewage waters was in the range of ND-22.3 ${\mu}$g/L. In 78 groundwater samples more than one VOCs were detected and VOCs concentration of the samples ranged from 0.1 ${\mu}$g/L to 387.1 ${\mu}$g/L. However, VOCs concentration of 66 samples out of 78 samples showed less than 10 ${\mu}$g/L and that of only 6 samples exceeded Korea drinking water limit (KDWL). 42 VOCs detected from the 168 groundwaters were 14 aromatic hydrocarbons out of 25, 27 chlorinated aliphatic hydrocarbons out of 35, and methyl tert-butyl ether (MTBE). Detection rate of each VOCs in the groundwaters was as follows: chloroform in 43 samples (25.6%), methylene chloride in 36 samples (21.4%), TCE in 26 samples (15.5%), 1,1-dichloroethane in 19 samples (1.3%), PCE in 16 samples (9.5%), cis-1,2-DCE in 15 samples (8.9%), and toluene in 14 samples (8.3%). Even though VOCs concentration in the groundwaters of the study area is still low, the city is expanding and the drinking water limit is becoming strict, and therefore continuous monitoring is necessary.