Study on the Performance Analysis of Building Automation Network (빌딩 자동화 통신망의 성능해석에 관한연구)

  • 홍승호;송원석
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.6
    • /
    • pp.359-364
    • /
    • 2003
  • BACnet is a standard data communication protocol for building automation and control systems. MS/TP is most widely used LAN protocol for data communication among field devices in the BACnet-based building automation. In this study, the performance of MS/TP protocol is investigated using a simulation model. This study evaluates the delay characteristics of MS/TP being used to deliver a BACnet application service. Analysis of the simulation results was used to identify the network parameters that influence the performance of BACnet application service and to develop recommendatioins that should be considered when designing and operating BACnet systems.

Determination of fungicides in wines by solid-phase extraction and gas chromatography with mass selective detection (고체상 추출법과 GC/MS를 이용한 포도주 중의 fungicides 정량)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.438-442
    • /
    • 2003
  • The fungicides, used for grape growth and remained in the wine products from domestic and foreign countries such as vinclozolin, dichlofluanid, penconazole, procymidone were quantitatively analyzed after solid-phase extraction using a GC/MS-SIM method. The results obtained were as follows: for all the samples, the content of procymidone was in the range from 2.2 to $76.1{\mu}g/L$, recoveries 81.3-93.1 %, and standard deviation 1.4-3.4 %.

GC/MS Analysis of Saccharin in Foods (GC/MS를 이용한 식품중 Saccharin의 분석에 관한 연구)

  • 노동석;김승기;이정애;정현숙;유보경;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.10 no.4
    • /
    • pp.239-247
    • /
    • 1995
  • Analytical method for saccharin in foods was developed using gas chromatography/mass spectrometry(GC/MS). Methylation with diazomethane, acetylation with MBTFA, and silylation with MSTFA and MTBSTFA were compared. Methylation of saccharin produced N-methylated saccharin as the major product and O-methylated saccharin as the minor one. Silylation of saccharin with MSTFA and MTBSTFA reasulted in the formation of the correponding O-silylated products, respectively. The derivatization of saccharin was optimized with MSTFA. The ions at m/z 240, 255, and 166 were monitored to characterize saccharin.

  • PDF

Analysis of nonionic surfactants and silicone polymers in cosmetic products using Matrix - assisted Laser Desorption/Ionization Time-of- flight Mass Spectrometry

  • Lee, Myoung-Hee;Lee, Gae-Ho;Yoo, Jong-Shin
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.480-507
    • /
    • 2003
  • A rapid and efficient method for analyzing the nonionic surfactants and silicone polymers, which control the shape and characteristics of cosmetic products and give influence on product quality, has been developed using Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI- TOF IMS). The MALDI-TOF/MS could easily and effectively determine the molecular weight distribution and monomer units of nonionic surfactants. As a result, creating a library of mass spectrum data of surfactants used in cosmetic products using MALDI-TOF/MS and analyzing surfactants extracted from the products may become a useful method for detailed structural characterization of the surfactants. Furthermore, the MALDI-TOF/MS analysis was effective in obtaining the spectrum of silicone polymers from which the molecular weight distribution could be determined. The repetition units and structural data could also be obtained through molecular mass peaks. Additionally, the monomer ratio and terminal groups as properties of silicone copolymers could be determined

  • PDF

Determination of methamphetamine in the hair of Korean abuser by CG/MS (GC/MS에 의한 한국인의 모발중 Methamphetamine검출)

  • 유영찬;정희선;최화경
    • YAKHAK HOEJI
    • /
    • v.37 no.4
    • /
    • pp.356-361
    • /
    • 1993
  • A sensitive method for the determination of methamphetamine(MA) and amphetamine(AM) in hair was developed by gas chromatography/mass spectrometry using stable isotope-labeled internal standards, amphetamine-d$_{5}$ and methamphetamine-d$_{5}$. Hair sample was washed with MeOH, incubated with MeOH(I% HCI) overnight at $37^{\circ}C$ while stirring and extracted using solid phase extraction column on a vacuum manifold. The extract obtained was pentafluoropropionated, and applied to GC/MS. The calibration curves of MA and AM were linear from 2.5 to 250 ng (r>0.99 for both). The limit of detection was 0.1 ng/mg in hair and cut-off level was set at 0.25 ng/mg for both. Hair samples of 27 MA abusers showed positive results in the range 0.7 to 106.8 ng/mg. AM, its metabolite, was detected in 20 out of 27 samples. The ratio of MA versus AM was 4.6~38.3 in specimens. Hair analysis for methamphetamine by GC/MS is an effective method for identifying long-term drug abusers.

  • PDF

Effects of RF pulsing and axial magnetic field onionized magnetron sputtering

  • Joo. Junghoon
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.2
    • /
    • pp.133-138
    • /
    • 1998
  • To enhance the ionization level of I-PVD and reduce the coil voltage two approaches were tried and as a diagnostic, optical emission spectroscopy and impedance analysis of the plasma was done with a range of Ar pressures and RF power along with XRD analysis of deposited Ag films. RF sputtering power was pulsed with various on/off time scales to recover the ICP quenched by sputtered metals. This in average enhances the ionization of the sputtered atoms with 10 ms/10 ms and 100 ms/100ms pulse on/off time duration and gives higher (200) preferred orientation over (111) in deposited Ag films. Secondly, Small axial B field about 8G remarkably reduced RF coil sputtering and showed scaled relationship between RF power and magnetic field strength for optimal process condition. From OES of Ar0 and Ar+, wave-like dispersion structure appeared and reduced the coil voltage about 20% at very weak field strength of 8G. This should be studied further to have nay relation with low mode helicon wave launching.

  • PDF

An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • Kim, Byeong Ju;So, Hyeon Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

Analysis of the in-plane shear behaviour of FRP reinforced hollow brick masonry walls

  • Gabor, A.;Ferrier, E.;Jacquelin, E.;Hamelin, P.
    • Structural Engineering and Mechanics
    • /
    • v.19 no.3
    • /
    • pp.237-260
    • /
    • 2005
  • This paper presents an experimental as well as a numerical analysis of the in-plane shear behaviour of hollow, $870{\times}840{\times}100mm$ masonry walls, externally strengthened with FRP composites. The experimental approach is devoted to the evaluation of the effectiveness of different composite strengthening configurations and the methodology consists in the diagonal compression of masonry walls. The numerical study assesses the stress and strain state distribution in the unreinforced and strengthened panels using a commercial finite element code. The effect of FRP reinforcement on the masonry behaviour and the capability of modelling to forecast a representative failure mode of the unreinforced and reinforced masonry walls is investigated.

Mass Spectrometry for Metabolome Analysis

  • Wang, Xiaohang;Li, Liang
    • Mass Spectrometry Letters
    • /
    • v.11 no.2
    • /
    • pp.17-24
    • /
    • 2020
  • Metabolomics has become an important research field with many areas of applications ranging from disease biomarker discovery to global biology systems study. A key step in metabolomics is to perform metabolome analysis to obtain quantitative information on metabolic changes among comparative samples. Mass spectrometry (MS) is widely used for highly sensitive detection of many different types of metabolites. In this review, we highlight some of the more commonly used MS techniques for metabolome analysis.

Identification and evaluation of fragmentation pathways of PDE-5 inhibitor analogues using LC-QTOF-MS (LC-QTOF-MS를 이용한 발기부전치료제 유사물질의 fragmentation pathway 분석)

  • Do, Jung-Ah;Noh, Eunyoung;Yoon, Soon-Byung;Park, Hyoung-Joon;Cho, Sooyeul;Park, Sung-Kwan;Yoon, Chang-Yong
    • Analytical Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.278-287
    • /
    • 2015
  • Phosphodiesterase type 5 inhibitors (PDE-5 inhibitors) are used in the treatment of erectile dysfunction. In recent years, a number of reports have been conducted on dietary supplements contaminated with PDE-5 analogues. In this study, 58 analogues of PDE-5 inhibitors were sorted into five groups: tadalafil, sildenafil, hongdenafil, vardenafil, and other analogues. These analogues were then evaluated using a liquid chromatography-quadrupole-time of flight mass spectrometry (LC-QTOF-MS) electrospray ionization mass method. Each compound has a unique fragmentation ion, which can be easily analyzed qualitatively. The fragmentation pathways of the analogues were elucidated based on the QTOF-MS and MS/MS data. Common ions were confirmed for each group by analyzing the structural characteristics and fragmentation pathways. Specifically, common ions were observed at m/z 169.08 and 135.04 (tadalafil analogues), m/z 311.15 and 283.12 (sildenafil analogues and hongdenafil analogues), and m/z 312.16 and 151.09 (vardenafil analogues). The advantage of this method is that the structure of unknown components can be determined by interpreting the product ions. Hence, the developed method can be used for the identification of unknown compounds. Fragmentation pathways may also aid in the detection and identification of PDE-5 inhibitor analogues.